Technical data
Output Time 0523 - 525 000
VDS-A
EN=180
Output 3 Output Event Type 0526 - 0527 05
VDS-A
EN=5
Output Area / Zone 0528 - 0529 00
Output Mode 0530 0
VDS-A EN=0
Output Time 0531 - 0533 180
VDS-A
EN=180
Output 4 Output Event Type 0534 - 0535 07
VDS-A
EN=5
Output Area / Zone 0536 - 0537 00
Output Mode 0538 0
VDS-A EN=0
Output Time 0539 - 0541 180
VDS-A
EN=180
Notice!
When the zone activating alarm is programmed as silent alarm, keypad and audible alarm have
no output.
For the corresponding value ranges of output event type, output mode and output time as well
as the relationship between output event type and Output in area see The Value Ranges of
Output Programming Options, page 39
The Value Ranges of Output Programming Options
Output Event Type Description Output Area / Zone
Output
Event
0 Not Used No
1 System Disarmed 0 = All Areas
1 – 16 = Areas 1 - 16
2 System Armed
3 System Alarm 0 = Any Area,
1 - 16 = Areas 1 - 16
4 System Alarm (audile and silent)
5 External AWAY Siren
6 External STAY Siren
7 Internal Siren
8 Internal Siren with tamper
9 Entry/Exit Delay Warning 1 - 16 = Areas 1 - 16
10 Telephone Line Fault
11 AC Power Supply Fault
12 Low Battery
13 Tamper 0 = Any Area,
AMAX panel 4000 / AMAX panel 4000
EN
Configuration | en 39
Bosch Sicherheitssysteme GmbH Quick Start Guide 2013.07 | 03 | F.01U.267.113