685 OWNERS MANUAL For COFFEE BREWERS MODELS: 0412 Decanter (In-Line) 0443 Decanter (In-Line Pour-Over) 0471 Decanter (Step-up Pour Over) 0472 Decanter (Step-Up) Model: 0482 Airpot Brewer 0482 Airpot/Thermal Server Model: 0443 Pour-Over Decanter Brewer Includes: Installation Operation Use & Care Servicing Instructions Model: 0412 In-Line Decanter Brewer Model: 0472 Stepped –Right Decanter Brewer PRINTED IN CHINA p/n 77110 Rev.
WARRANTY STATEMENT It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. The prices charged by Bloomfield Industries for its products are based upon the limitations in this warranty. Seller’s obligation under this warranty is limited to the repair of defects without charge by a Bloomfield Industries Authorized Service Agency or one of its sub-agencies. This service will be provided on customer’s premises for non-portable models.
TABLE OF CONTENTS WARRANTY STATEMENT SPECIFICATIONS FEATURES & OPERATING CONTROLS PRECAUTIONS & GENERAL INFORMATION AGENCY LISTING INFORMATION INSTALLATION INSTRUCTIONS OPERATION BREWING COFFEE CLEANING INSTRUCTIONS TROUBLESHOOTING SUGGESTIONS SERVICING INSTRUCTIONS Deliming Instructions EXPLODED VIEW & PARTS LIST WIRING DIAGRAMS xi 1 2 3 4 5 8 9 10 11 12 17 18 26 Thank You for purchasing this Bloomfield Industries appliance.
FEATURES AND OPERATING CONTROLS - AUTOMATIC BREWERS 685 77110 Owners Manual Horizon™ Brewers Fig.
685 77110 Owners Manual Horizon™ Brewers FEATURES AND OPERATING CONTROLS - POUR-OVER BREWERS Fig.
PRECAUTIONS AND GENERAL INFORMATION WARNING: ELECTRIC SHOCK HAZARD All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock. WARNING: INJURY HAZARD All installation procedures must be performed by qualified personnel with full knowledge of all applicable electrical and plumbing codes.
INSTALLATION READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION Unpack the unit. Inspect all components for completeness and condition. Ensure that all packing materials have been removed from the unit. Verify that the Spray Head Gasket and Spray Disk are properly installed. LEVELING THE UNIT Verify that an adjustable leg is installed at each corner of the brewer. NOTE: Various combinations of legs and spacers are available for Model 0482 airpot brewer.
INSTALLATION (continued) READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION CAUTION: ELECTRICAL DAMAGE DO NOT plug in or energize this appliance until all Installation Instructions are read and followed. Damage to the Brewer will occur if these instructions are not followed. IMPORTANT: Tank must be full of water before connecting brewer to electric power. Heating elements will be damaged if allowed to operate without being fully submerged in water. See instructions for filling tank, page 8.
INSTALLATION (continued) ELECTRICIAN’S INSTALLATION INSTRUCTIONS REFER TO ELECTRICAL SPECIFICATIONS - Page 1 Check the nameplate to determine correct electrical service required for the Brewer to be installed. IMPORTANT: Before connecting to electricity, make sure automatic brewers are connected to the water supply. NOTE: Does not apply to 0443 and 0471 pour-over brewers. All models are equipped with a cord and plug.
OPERATION IMPORTANT: TANK MUST BE FULL OF WATER BEFORE CONNECTING BREWER TO ELECTRIC POWER. Heating elements will be damaged if allowed to operate without being fully submerged in water. Damage caused by operating the brewer without water in the tank is NOT COVERED BY WARRANTY. A. START-UP For initial start-up, or if the brewer has not been used for an extended period of time: ♦ Be sure spray disk and brew gasket are properly installed in the brew head.
BREWING COFFEE A. PREPARATION CAUTION: Place one (1) genuine Bloomfield paper filter in the brew chamber. Add a pre-measured amount of fresh coffee grounds. Gently shake the brew chamber to level the bed of grounds. Slide the brew chamber into place under the brew head. BURN HAZARD Exposed surfaces of the brewer, brew chamber, decanter and/or airpot may be HOT to the touch, and can cause serious burns. CAUTION: BURN HAZARD Fig. 7 Brew Chamber B. AUTOMATIC OPERATION Be sure “READY” light is lit.
CLEANING INSTRUCTIONS CAUTION: PROCEDURE: Clean Coffee Brewer BURN HAZARD Brewing and serving temperatures of coffee are extremely hot. Hot coffee will cause serious skin burns. PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. FREQUENCY: Daily TOOLS: Mild Detergent, Clean Soft Cloth or Sponge Bristle Brush, Bottle Brush CAUTION: SHOCK HAZARD Do not submerge or immerse brewer in water.
685 77110 Owners Manual Horizon™ Brewers TROUBLESHOOTING SUGGESTIONS SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY Water won’t heat Brewer unplugged or circuit breaker tripped Check power supply cord Check / reset circuit breaker Temperature setpoint too low Set for desired temperature Hi-Limit safety switch tripped Allow to cool hi-limit will selfreset Damaged internal component or wiring Examine wiring & connectors, thermostat and heating element Repair/replace as needed Coffee level too high or lo
SERVICING INSTRUCTIONS CAUTION: SHOCK HAZARD Opening access panels or removing warmer plates on this brewer may expose uninsulated electrical components. Disconnect brewer from electrical power before removing any panel Trouble shooting guides, component views and parts lists are included for general reference, and are intended for use by qualified service personnel.. ACCESS PANELS WARMER PLATES: Warmer plates unscrew counter-clockwise.
SERVICING INSTRUCTIONS (continued) TEMPERATURE ADJUSTMENT CAUTION: Disconnect brewer from electric power. Remove top panel. Remove button plug from front panel. Pull vent tube out of tank lid and insert a thermometer of known accuracy in hole. Reconnect brewer to electrical power. Place empty container under brew chamber. Energize brewer and allow unit to heat. When READY light glows, read the temperature displayed on thermometer. These procedures involve exposed electrical circuits.
SERVICING INSTRUCTIONS (continued) IMPORTANT: Water pressure must be between 20 p.s.i and 90 p.s.i. flowing pressure. If water pressure exceeds this value, or if water pressure varies greatly, a pressure regulator must be installed in the water supply line. NOTE: DELAY is the amount of time before a second brew can be initiated, and is factory set for 5 minutes. LOCK and ALARM are not used. IMPORTANT: Before setting assembly into tank, make sure tank lid gasket is properly seated on flange of lid.
SERVICING INSTRUCTIONS (continued) REPLACE SOLENOID Symptom: Automatic brewer will not flow water; or, automatic brewer drips continuously from brew head. NOTE: Wrench p/n 86660 is designed to allow easy removal of the hoses from the plastic solenoid valve. IMPORTANT: Shut-off water and disconnect brewer from electric power before removing hoses or wiring. Remove top cover and detach solenoid access door from cabinet. Remove faucet tube from faucet valve at flare fitting.
SERVICING INSTRUCTIONS (continued) REPLACE TIMER ASSEMBLY Disconnect brewer from electric power. Remove front panel. Remove three screws holding timer to bracket. Disconnect wiring to timer. Reassemble in reverse order. Adjust timer as described on page 14. IMPORTANT: When replacing water faucet coil, also replace seal gaskets. REPLACE HOT WATER FAUCET COIL Symptom: Brewer drips continuously from brew head, except when faucet valve is turned OFF. Remove tank lid assembly per above.
SERVICING INSTRUCTIONS (continued) PROCEDURE: Delime the Water Tank CAUTION: PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. FREQUENCY: As required (Brewer slow to heat) TOOLS: Deliming Solution Protective Gloves, Goggles & Apron Mild Detergent, Clean Soft Cloth or Sponge Bristle Brush, Bottle Brush Large Sink (or other appropriate work area) 1. Disconnect brewer from electric power.
EXPLODED VIEW & PARTS LIST PLUMBING & RELATED COMPONENTS - AUTOMATIC BREWERS MODELS: 0412, 0472, 0482 685 77110 Owners Manual Horizon™ Brewers 18
EXPLODED VIEW & PARTS LIST (continued) 685 77110 Owners Manual Horizon™ Brewers PLUMBING & RELATED COMPONENTS - POUR-OVER BREWERS MODELS: 0443, 0471 19
EXPLODED VIEW & PARTS LIST (continued) CABINET & ELECTRICAL COMPONENTS - AUTOMATIC IN-LINE DECANTER BREWER MODEL: 0412 685 77110 Owners Manual Horizon™ Brewers 20
EXPLODED VIEW & PARTS LIST (continued) 685 77110 Owners Manual Horizon™ Brewers CABINET & ELECTRICAL COMPONENTS - POUR-OVER IN-LINE DECANTER BREWER MODEL: 0443 21
EXPLODED VIEW & PARTS LIST (continued) CABINET & ELECTRICAL COMPONENTS - AUTOMATIC STEP-UP DECANTER BREWER MODEL: 0472 685 77110 Owners Manual Horizon™ Brewers 22
EXPLODED VIEW & PARTS LIST (continued) 685 77110 Owners Manual Horizon™ Brewers CABINET & ELECTRICAL COMPONENTS - POUR-OVER STEP-UP DECANTER BREWER MODEL: 0471 23
EXPLODED VIEW & PARTS LIST (continued) CABINET & ELECTRICAL COMPONENTS - AUTOMATIC AIRPOT/THERMAL BREWER MODEL: 0482 685 77110 Owners Manual Horizon™ Brewers 24
EXPLODED VIEW & PARTS LIST (continued) SERVICE KITS 685 77110 Owners Manual Horizon™ Brewers FAUCET REPAIR KITS 82573 Handle (item 12a) 82575 Seat Cup (item 12c) 82576 Faucet Repair Kit (Includes 12a Handle, 12c Seat Cup, 12d Spring, 12h Stem, 12j Pin & 12k Bonnet 82682 Retainer Clip (item 12b) 84804 Aerator Replacement Kit (Includes 12e O-Ring, 12f Aerator Disk & 12g Aerator Cap 84870 Aerator Repair Kit (Includes 12e O-Ring & 12f Aerator Disk) SOLENOID REPAIR KITS 83612 Solenoid Complete, Single 84455 S
WIRING DIAGRAM AUTOMATIC BREWERS 685 77110 Owners Manual Horizon™ Brewers 26
WIRING DIAGRAM (continued) 685 77110 Owners Manual Horizon™ Brewers POUR-OVER BREWERS 27
Bloomfield Industries proudly supports CFESA Commercial Food Equipment Service Association Bloomfield Industries, Inc. Division of Carrier Commercial Refrigeration In US and Canada Telephone: 775-689-5700 Fax: 888-492-2783 Fax: 800-356-5142 (for orders only) website: www.wellsbloomfield.