User's Manual

P a g i n a | 5
MANUAL | yooBee Sensor yB-010020-SR
3. Installation
The yooBee Sensor can be fixed to a window by means of a suction cup (yB-020022-SCT) or
mounted under a lamp by means of a flat bracket (yB-020021-SFB). Please see the
InstallationGuide for detailed instructions.
4. Troubleshooting
The yooBee Sensor has a multi-colored LED, that can be used for troubleshooting:
LED Code
Meaning
1x red short blink
Button press detected
2x red short blink
USB power connected
series of short blue blink
Firmware update
1x red after firmware update blue blinks
Firmware update failed
In case of possible malfunction, please contact technical support to receive proper
replacements (email: support@blooloc.com). Replacement policy also applies to performance
faults caused by low battery before certain operation time.
5. Disposal of the device
yooBee Sensors contain electronic elements and batteries which should be properly disposed
and compliant to local regulations.
6. Safety Instructions
Opening yooBee Sensors is strictly forbidden. Switching the original battery with one of a
different type might cause a risk of explosion.
7. Technical Specifications
Dimensions
88 mm x 88 mm x 17 mm
Operational
Temperature
-20°C to +40°C
Weight
84 g
Storage Temperature
-25°C to +40°C
Radio
NFC Forum Type 4,
ISO/IEC14443
2.4 GHz BLE 0dBm TX power
iBeacon (6Hz)
Sensor
Ambient temperature
Power
Requirements
560mAh rechargeable Li-Ion
battery
USB port (charging and/or
power in case of dark
surroundings)
Material
Reinforced
polyamide
UV-light resistant
Zero outgassing