DESIGN AND OPERATING LOGIC
The unit has the following operating logic: warm stale extract air from the room flows into the unit, where it is filtered by the extract filter,
then air flows through the heat exchanger and is exhausted outside by the extract fan. Cold fresh air from the outside flows into the unit,
where it is cleaned by the supply filter.
Then the air flows through the heat exchanger and is directed to the room with the supply fan. Heat energy of warm extract air is
transferred to clean intake fresh air from the outside and warms it up. The air flows are fully separated while flowing through the heat
exchanger. Heat recovery minimizes heat losses, which reduces the cost of space heating in the cold season.
UNIT DESIGN
1
2
3
6
7
8
5
4
9
10
11
12
1 — supply fan, 2 — extract filter G4, 3 — heat exchanger, 4 — control unit, 5 —extract fan, 6 — bypass damper (for KOMFORT EC D5B180-E
models), 7 — supply filter F7, 8 — supply filter G4, 9 — Setup Mode button (for KOMFORT (EC) D5(B)180-E S21 models), 10 — duct
preheater connector (for KOMFORT (EC) D5(B)180-E S21 models), 11 — duct reheater connector (for KOMFORT (EC) D5(B)180-E S21
models), 12 — cable glands.
The service side of the unit is equipped with detachable plates fixed by screws for filter cleaning and replacement operations. The control
unit is positioned inside the unit casing. The power cable and grounding cable are connected to the control unit via the electric lead-
ins placed at the side of the unit. The difference between the supply and extract air flow temperature leads to condensate generation.
Condensate is collected in the drain pan and is removed outside through the drain pipes.
Additional equipment for the unit is purchased separately as an accessory (is not included in the delivery set, available
separately):
Humidity sensor (FS2 is connected to the terminal block, HR-S is connected to the controller).
The unit with an installed humidity sensor maintains a set indoor humidity point. As the extract air humidity rises above the set point,
the system automatically switches to the maximum speed. As the humidity drops down below the set point the unit returns to the
previous mode.
CO
2
sensor (is connected to the controller).
The sensor is designed for indoor carbon dioxide concentration measurement and respective air capacity regulation through the
control output signal to the fan. Air capacity control based on CO
2
concentration is an efficient energy saving solution.
VOC sensor (is connected to the controller).
Qualitative assessment of air saturation with contaminants (cigarette smoke, exhaled air, solvent and detergent vapours). The sensor
sensitivity can be adjusted with regards to the expected maximum level of air pollution. Enables on-demand ventilation which results
in considerable energy savings as air is exchanged only upon reaching the preset level of pollution.
Duct preheater.
The heater maintains air temperature in the supply duct at level that prevents the heat exchanger from freezing. Heater installation
and connection to the unit are described in the heater users manual.
Duct reheater.
The heater maintains the user-defined room air temperature. Heater installation and connection to the unit are described in the
heater users manual.