ALP Installation Guide

ALP AMBIENT LIGHT PANEL INSTALLATION INSTRUCTIONS, FOR USE WITH BEST LINERS MODELS L5230, L7030, L7036, L7048, L2936, L2942,
L3848, L3854, L3860, L3336S, L3342S, L4548S, L4554S
AND L4560S ONLY.
INSTALLATION DU PANNEAU DÉCLAIRAGE DAMBIANCE ALP - NE CONVIENT QUAUX RECOUVREMENTS DARMOIRE BEST DE MODÈLE L5230, L7030,
L7036, L7048, L2936, L2942, L3848, L3854, L3860, L3336S, L3342S, L4548S, L4554S ET L4560S SEULEMENT.
INSTRUCCIONES PARA LA INSTALACIÓN DEL TABLERO DE ILUMINACIÓN AMBIENTAL ALP SÓLO PARA REVESTIMIENTOS BEST DE LOS MODELOS L5230,
L7030,L7036, L7048, L2936, L2942, L3848, L3854, L3860, L3336S, L3342S, L4548S, L4554S Y L4560S.
ENGLISH READ AND SAVE THESE INSTRUCTIONS - INSTALLER: LEAVE THIS INSTRUCTION SHEET WITH THE HOMEOWNER.
THIS KIT CONTAINS: • ONE ALP AMBIENT LIGHT PANEL WITH ONE GROMMET
IF ALREADY INSTALLED, REMOVE THE FRONT PANEL SECTION (A) FROM THE CUSTOM HOOD BASE. TAKE CARE NOT TO SCRATCH MAIN LINER PLATE WHEN REMOVING
FRONT PANEL SECTION OF LINER. (SEE FIGURE 1.)
NOTE: DO NOT DISCARD THE SCREWS, KEEP THEM FOR FUTURE USE.
TURN OFF POWER AND LOCK OUT SERVICE PANEL BEFORE WIRING AMBIENT LIGHT PANEL.
R
UN A 2-WIRE PLUS GROUND POWER CABLE (NOT SUPPLIED) TO AMBIENT LIGHT PANEL LOCATION THROUGH A HOLE IN THE BOTTOM OF THE CUSTOM HOOD BASE
LOCATED WITHIN THE GREY ZONE AS SHOWN. (SEE FIGURE 2.)
NOTE: I
F THE MAIN LINER PLATE COVERS THE BOTTOM OF THE CUSTOM HOOD WHERE THE POWER CABLE WILL ENTER, YOU WILL NEED TO PROVIDE A HOLE THROUGH
THE MAIN LINER PLATE AS WELL. TODOTHIS, DISASSEMBLE THE MAIN LINER PLATE AND INSERT (WITH INTERNAL BLOWER IF APPLICABLE) FROM THE CUSTOM
HOOD. PUNCH OR DRILL A 5/8’ DIAMETER HOLE THROUGH THE MAIN LINER PLATE IN THE LOCATION SHOWN (GREY ZONE IN FIGURE 2). DEBURR THE SHEET METAL HOLE.
PARTIALLY REASSEMBLE THE MAIN LINER PLATE AND TRACE THE 5/8’ METAL HOLE ONTO THE BOTTOM OF THE CABINET WITH A PENCIL. REMOVE THE MAIN LINER PLATE AGAIN
AND DRILL A
3/4’ DIAMETER MINIMUM HOLE IN THE BOTTOM OF THE CUSTOM HOOD, LOCATED ON THE SAME CENTERPOINT AS THE HOLE IN THE MAIN LINER PLATE. REINSTALL
MAIN LINER PLATE AND INSERT. INSERT THE PLASTIC GROMMET (PROVIDED) THROUGH HOLE IN MAIN LINER PLATE PRIOR TO PASSING THE ELECTRICAL CABLE THROUGH IT.
(SEE FIGURE 3.)
STUB OUT ENOUGH LENGTH OF CABLE BELOW THE CUSTOM HOOD TO PERFORM THE AMBIENT LIGHT PANEL ELECTRICAL CONNECTION.
NOTE: W
HEN DRILLING HOLE, PROTECT COOKTOP AND COUNTERTOP SURFACES.
R
EMOVE THE 4 SCREWS RETAINING THE SMALL PLATE COVERING THE ELECTRICAL COMPARTMENT OF THE AMBIENT LIGHT PANEL. (SEE FIGURE 4.)
R
EMOVE THE WIRING KNOCKOUT LOCATED ON THE AMBIENT LIGHT PANEL END AND INSTALL APPROVED ELECTRICAL CABLE CLAMP (NOT SUPPLIED). PASS THE POWER CABLE THROUGH
THE CABLE CLAMP AND TIGHTEN THE WIRE CLAMP TO SECURE THE POWER CABLE. (SEE FIGURE 5.)
C
ONNECT THE POWER CABLE TO THE AMBIENT LIGHT PANEL WIRES USING WIRE CONNECTORS (NOT SUPPLIED) AS FOLLOWS: WHITE TO WHITE (B), BLACK TO BLACK (C), AND
GREEN OR BARE WIRE UNDER GREEN GROUND SCREW (D) INSIDE THE AMBIENT LIGHT PANEL. (SEE FIGURE 6.)
R
EINSTALL THE SMALL PLATE COVERING THE ELECTRICAL COMPARTMENT.
S
LIDE THE AMBIENT LIGHT PANEL (E) FORWARD INTO THE NOSE OF THE CUSTOM HOOD BASE. TAKE CARE NOT TO SCRATCH MAIN LINER PLATE WHEN INSTALLING
AMBIENT LIGHT PANEL
. ASSEMBLE IT TO THE CUSTOM HOOD BASE, USING ONE SCREW PER SCREW HOLE. (SEE FIGURE 7.)
R
ESTORE POWER AND TEST THE ON/OFF ROCKER SWITCH LIGHT CONTROL.
THIS AMBIENT LIGHT PANEL MUST USE SHIELDED HALOGEN LAMPS (120 V, 50 W, MR16 OR PAR16 WITH GU10 BASE), INCLUDED.
1. INSTALL THE LAMPS BY PLACING THE BULB LEADS INTO THEIR GROOVES IN THE SOCKET.
2. GENTLY PUSH UPWARDS AND TURN CLOCKWISE UNTIL SECURE.
TO REMOVE LAMPS, GENTLY PUSH UPWARDS AND TURN COUNTERCLOCKWISE TO DISENGAGE BULB LEADS FROM THEIR GROOVES.
NOTE : I
F NEED BE, USE A RUBBER DISHWASHING GLOVE TO ADD GRIP WHEN REMOVING THE BULB.
F
OR DETAILS ON CLEANING, SEE INSTRUCTIONS INCLUDED WITH INSERT OR POWER PACK.
FRANÇAIS LIRE ET CONSERVER CES INSTRUCTIONS - INSTALLATEUR : LAISSER CETTE FEUILLE DINSTRUCTION AU PROPRIÉTAIRE.
CET ENSEMBLE COMPREND :• UN PANNEAU DÉCLAIRAGE DAMBIANCE ALP ET UN PASSE-FILS
SUITE AU VERSO
WARNING
WARNING
Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Turn off power and lock out service panel before
installing, wiring, or servicing this product. This unit must be grounded.
3''
2''
HD0096
BOTTOM VIEW / VUE DU DESSOUS / DEBAJO
FRONT / AVANT / FRENTE
2
3
!
HD0097
4
HA0034
AVERTISSEMENT
Risque de choc électrique. Le raccordement électrique doit être effectué par du personnel qualifié conformément aux codes et standards. Avant d’installer, d’effectuer le branchement ou
l’entretien de ce produit, coupez l’alimentation électrique au panneau de service et verrouillez-le. Cet appareil doit être mis à la terre.
!
WARNING
!
When cutting or drilling into wall, do not damage electrical wiring and other hidden utilities.
HA0020
A
1
CAUTION
Before installing, remove the protective plastic film and tape from all parts.
WARNING
!
The ambient light panel power cable (not supplied) must be minimum 90°C (194°F) supply conductors.
5
HE0029
B
C
D
6
HA0020
E
7
12
HO0090
ATTENTION
Retirer le film de plastique protecteur ainsi que le ruban gommé de toutes les pièces avant de procéder à l’installation.
SERVICE PARTS
SV05921 Shielded Halogen Lamp 120 V, 50 W, GU10
SV16569 Lamp Shell, Socket & Trim Assembly
SV02563 Rocker Switch
In order to prevent the risk of personal injury, do not install a lamp identified for use only in enclosed fixtures.
!
1
2
3
4
5
6
7
8
9
WARNING
In order to prevent the risk of personal injury, the halogen lamps must be cooled down before removing them.
!
HA0036

Summary of content (2 pages)