Technical Manual

Continuous Feed Food Processors
Berkel M2000 / M3000
18
MODEL M2000 and M3000
MOTOR
White
Black
ON/OFF SWITCH
Black
Ground
WHITE
ELECTRICAL WIRING DIAGRAM
CONTACT NORMALLY OPEN
REED SWITCH
RELAY
4
B
3
A
NOTE: The Reed Switch is a magnetically operated safety switch. It is not a fuse.
The contact closes when the Magnet in the toggle lock locates above the Reed Switch.
REED SWITCH ASSEMBLY WITH WIRES FOR M2000 (PART #2322-B)