User's Guide

11
19 Cool Temp Range 50 / 10 °F range: 50 - 99
°C range: 10
-
37
20 Extend Fan On
Time Heat
0 0 - no delay
90
-
90 seconds delay
21 Extend Fan On
Time Cool
0 0 - no delay
90
-
90 seconds delay
22 Key Lock Disable Disable / Enable
23 Temp Calibration 0 °F range: -9 - 9
°C range: -4.5 - 4.5
24 Standby 1 min 30s - no button operation in 30
seconds to enter standby
1min - 1 minute without key operation
to enter standby (default)
2min - no button operation in 2 minutes
to enter standby
5min - 5 minutes without button
operation to enter standby
10min - no button operation in 10
minutes to enter standby
Never - no standby
25 Reset Thermostat 0 Adjust this value to 1 and confirm. All
parameters will then be restored to
the factory settings
26 Factory Test Factory test related content
TIMING Setting
A TIMING schedule will activate the thermostat at the preset time and
will keep the room temperature within your preset range.