RX100 Dome Interface Receiver Installation Guide Building Block Video Ltd., 17 Apex Park, Diplocks Industrial Estate, Hailsham, East Sussex, BN27 3JU UK. Tel: +44(0)1323 842727 Fax: +44(0)1323 842728 Support: +44(0)1323 444600 www.bbvcctv.
TABLE OF CONTENTS 1. Pre-installation Checks and Safety Procedures 3 Unpacking Important safety precautions 3 3 2. Introduction 5 General Rx100 Technical specification Transmitter compatibility chart Cable connection method 5 5 6 7 Fig. 1 Wago cable connectors Cable types 7 3. Installation 8 Operating voltage Rx100 connections 8 8 Fig. 2 Rx100 pcb connections 4. Setup 9 Diagnostic aids Cable length compensation 9 9 Fig. 3 Launch amplifier 5. System schematic diagrams 10/11 Fig.
1. PRE-INSTALLATION CHECKS AND SAFETY PROCEDURES UNPACKING Check Packaging - Upon taking delivery of the unit, inspect the packaging for signs of damage. If damage has occurred, advise the carriers and/or the suppliers immediately. Check Contents - Upon taking delivery of the unit, unpack the unit carefully and check that all the items are present and correct. If any items are missing or damaged, contact your equipment dealer.
Damage Requiring Service - Servicing by qualified personnel should be carried out under the following conditions: (a) When the power-supply cord or plug is damaged. (b) If liquid has been spilled or objects have fallen into the unit (c) If the internal electronics of the unit have been exposed to rain or water (d) If the unit does not operate normally by following the operating instructions.
2. INTRODUCTION GENERAL The Rx100 telemetry interface is designed to allow control of a variety of integrated dome cameras using BBV’s range of up-the-coax telemetry transmitters. See appendix A for a complete list of supported domes. The Rx100 interface is supplied in an IP67 rated enclosure. It will be necessary to make suitable holes in the enclosure to permit cable entry and exit.
TRANSMITTER COMPATABILITY CHART Tx300 Variable Speed Fixed Speed Zoom Focus Iris Pre-sets Patrols Lights Autopan Camera Functions Tx400 Tx400DC Tx1000 Tx1000DC Tx1500 2 Speeds 2 Speeds Proportional Joystick 2 Speeds Proportional Joystick Proportional Joystick 9 9 9 9 9 - 9 9 9 9 8 2 9 9 9 9 9 9 9 8 2 9 9 9 9 9 9 9 16 2 9 9 9 9 9 9 9 16 2 9 9 9 9 9 9 9 16 2 9 9 9 Rx100 installation manual V1.16 01May08.
CABLE CONNECTION METHOD Fig. 1: cage clamp connectors The cage clamp PCB terminal block is a simple-to-use method of attaching cables to PCBs quickly and easily. Prepare cables as follows: • • Use only cable between 0.08 and 2.5 mm² Strip the cable to a length of 5 to 6 mm (0.23 in) The correct method of attachment is as follows: 1. Press down the relevant terminal block lever with a suitable screwdriver; 2. Insert wire; 3. Remove screwdriver.
3. INSTALLATION OPERATING VOLTAGE The Rx100 requires all connections to the PCB to be made by the installer, and via terminal blocks or by plug and socket. These connections are: power in, video in, video out, and serial data to dome. In addition connections for alarm in, alarm out and lights if required are provided. See fig.2 below for correct connections. The Rx100 is supplied pre-configured to suit the application for which it is intended, i.e. to control an integrated dome camera.
4. SETUP DIAGNOSTIC AIDS Two red LEDs and one Green LED are mounted on-board to give simple system status information. Their functions are as follows: Cable LED Regular Blinking Blinking but mainly ON Blinking but mainly OFF - Telemetry and video signals are OK. No Telemetry from the transmitter. No video from the camera. Error LED On - Telemetry transmission error. Both LEDs Off - No power or major PCB fault.
4. SYSTEM SCHEMATIC DIAGRAMS Rx100 static camera dome camera 4 local alarms Rx200 static camera with lights/wash/wipe Rx300 AC P/T Zoom/Focus 1 Aux. Rx400P AC P/T Zoom/Focus 16 Presets with 4 Aux. STATIC Rx400DC Rx45X AC Rx55X DC High & Variable speed P/T Zoom/Focus 16 Preset with 3 Aux. 8 Local alarms BBV RS485 AC Fixed Speed P/T Zoom/Focus 32 Preset with 4 Aux. 8 Local alarms BBV RS485 High & Variable speed P/T Zoom/Focus 32 Preset with 3 Aux.
Fig.5 SYSTEM SCHEMATIC SHOWING INTEGRATION OF DOME INTO Tx1000 SYSTEM. Rx400DC Rx200 Rx100 static camera with lights/ wash/wipe dome camera 4 local alarms static camera STATIC Rx300M Rx200 simple AC panner Rx400P AC P/T Mitsubishi CCD400 control 2 Aux. Rx300 AC P/T Zoom/Focus 1 Aux. High & Variable speed P/T Zoom/Focus 16 Preset with 3 Aux. 8 Local alarms AC P/T Zoom/Focus 16 Presets with 3 Aux.
Appendix A - Dome addendums & connection details Rx100/24 iss. 4 pcb 13 360 Vision VisionDome 14 Borsatec BT2790FF Dome 15 Chugai SMD-08ll, SMD-12, SMD-12ll, SMD-20 31 Dennard 2050 16 Diamond-Smartscan 36 Dynacolor 7720 17 Forward Vision MIC1300 18 Gardiner Security Juno 14 JVC TK-C675E / TK-C675BE 19 Kalatel Cyberdome (1/1/2002 or later firmware) 20 Li-Lin PIH-717X/7000/7600/7625 21 Mark Mercer D250MPT 22 Panasonic WV-CSR400, WV-CSR600.
BBV Rx100/24 Supply Additional information (iss. 6 pcb) The RX100/24 can be powered from either 230Vac or 24Vac. The diagrams below shows the connections that should be made for each supply voltage. Please note that when powered from 24Vac the 230Vac terminals will be at mains voltages. To prevent the risk of shocks the fuse must be removed from the fuse holder and no connections made to L and N. The 24Vac supply must be fused with a 315mA to protect the supply wiring. Fig 9. RX100/24 iss.
BBV Rx100 Interface Receiver Addendum to manual for the following domes: 360 Vision VisionDome Gardiner Security Juno Rx100 software RX1_31V2 Application Notes The RX 100 provide the following functionality when controlling the above mentioned domes Variable speed Pan/Tilt. Zoom/Focus, Focus/Iris Override returning to auto after Zoom In/Out. 16 Full scene presets. 2 preset patrols. Slow preset tour.
BBV Rx100 Interface Receiver Addendum to manual for the following domes: Borsatec BT2790FF Dome Rx100 software RX1_B3V2 Application Notes The RX100 provides the following functionality when controlling the above mentioned dome: Variable speed Pan/Tilt. 16 Full scene presets. 2 RX100 preset patrols. Pattern 1 learn and playback 2 preset patrols. 4 alarm inputs moving to preset 1 - 4 Additional commands: Advanced Features Dome MENU (Preset 95) Start Patten 1 (Preset 81) B L C.
BBV Rx 100 Interface Receiver Addendum to manual for the following domes: Dennard type 2050/2055/2060 dome. Rx100 software RX1_D2V12 Application Notes Variable speed Pan/Tilt.
BBV Rx 100 Interface Receiver Addendum to manual for the following dome: Dynacolor 7720 COAXIAL TELEMETRY ONLY NOT 20mA Rx100 software RX1_D4V7 Application Notes Variable speed Pan/Tilt (single function at a time, pan or tilt or zoom or focus) Zoom/Focus 16 full scene presets 2 preset patrols 4 alarm inputs driving to preset 1 – 4 Additional Features Dome Menu and ENTER Exit Dome Menu Dome Reset Tx400 ‘#’ 1 ‘#’ 2 (3 times) ‘#’ 4 (twice) Tx1000 '#' WASH ‘#’ WIPE ‘#’ LIGHTS Tx1500 1 '#' 2 ‘#’ 4 ‘#’ DM Sp
BBV Rx 100 Interface Receiver Addendum to manual for the following domes: Forward Vision protocol including MIC1 300/400 series dome and compatible equipment. Rx100 software RX1_F1V8 Application Notes Variable 16 speed Pan/Tilt.
BBV Rx 100 Interface Receiver Addendum to manual for the following dome: JVC TK-C655B/676/675B combination cameras Rx100 software RX1_J2V4 Application Notes The RX 100 provides the following functionality when controlling the above mentioned domes Variable speed Pan/Tilt. Zoom/Focus, Autofocus can be enabled/disabled from the dome menu. 16 Full scene presets. 2 preset patrols. Slow patrol or dome autopan from controller AUTOPAN key 4 alarm inputs driving to preset 1 - 4.
BBV Rx100 Interface Receiver Addendum to manual for the following domes: Kalatel Cyberdome (Firmware 1/1/02 or later) Rx100 software RX1_K1V2 Application Notes Variable speed Pan/Tilt. Zoom/Focus/Iris 16 Full scene presets. 2 preset patrols. (PATROL1 = RX100 patrol and PATROL 2 = dome’s TOUR 03) Shadow TOUR 1 playback using AUTOPAN key.
BBV Rx 100 Interface Receiver Addendum to manual for the following dome: Merit Li-Lin PIH-717X/7000/7600/7625 series Rx100 software RX1_L1V8 Application Notes Variable speed Pan/Tilt.
BBV Rx 100 Interface Receiver Addendum to manual for the following domes: Mark Mercer 150 and D250/500 series Rx100 software RX1_M1V6 Application Notes Variable speed Pan/Tilt. Zoom/Focus override, Iris override 16 full scene presets 2 preset patrols 4 alarm inputs driving to preset 1 – 4 2 minute datum (park) mode, link selectable as either preset 1 or slow preset patrol.
BBV Rx 100 Interface Receiver Addendum to manual for the following domes: Panasonic WV-CSR400 series. WV-CSR600 series. WV-CSR650 series. Rx100 software RX1_P1V5B Application Notes Variable speed Pan/Tilt. Zoom/Focus, Autofocus, Iris Open/Close 16 full scene presets 2 preset patrols 4 alarm inputs driving to preset 1 - 4.
BBV Rx 100 Interface Receiver Addendum to manual for the following domes: Panasonic WV-CS850 / 860 Rx100 software RX1_P1V10 Application Notes Variable speed Pan/Tilt.
BBV Rx 100 Interface Receiver Addendum to manual for the following dome: Pelco Spectra (P-mode RS485 protocol) Rx100 software RX1_P2V10 Application Notes Variable speed Pan/Tilt.
BBV Rx 100 Interface Receiver Addendum to manual for the following dome: Philips AutoDome including G3A and G3B (RS232 control only, not Bi-Phase compatible) Rx100 software RX1_P3V11 Application Notes Variable speed Pan/Tilt.. Zoom/Focus, Autofocus. 16 full scene presets. 2 preset patrols. 4 alarm inputs driving to preset 1 – 4. Dome AutoPlay record & playback.
Using the advanced features when using a BBV Tx400DC Menu Access: Press and HOLD # and tap 1 TWICE will display the dome’s menu Use the joystick to navigate the cursor. FOCUS FAR or FOCUS NEAR can be pressed to enter the next menu item or to return press either IRIS OPEN or IRIS CLOSE. When completely out of the menu issue a goto preset command to put the Rx100 into normal mode. Press 1 will move to preshot 1.
BBV Rx100 & Rx100/24 Addendum to manual for the following domes: Samsung SCC-641 Interface Rx100 software RX1_S5V3 Application Notes The Rx100 allows control of the following dome features: Variable speed Pan/Tilt, Zoom/Focus/Iris, 16 full scene presets, 2 preset patrols, 4 alarm inputs driving to preset 1 – 4, Dome Pattern 1 playback using the AUTOPAN key ,Menu Access Advanced Features Display Menu (Twice) Turn Menu Off ENTER within menu Dome FACTORY RESET BBV Tx1000 '#' WASH '#' WIPE '#' AUTOPAN '#' LIG
BBV Rx 100 Interface Receiver Addendum to manual for the following domes: Sensormatic Speeddome Rx100 software RX1_S3V6 Coaxial telemetry ONLY. Not twisted pair! Application Notes Variable speed Pan/Tilt.
BBV Rx 100 Interface Receiver Addendum to manual for the following camera: Sony EVI-D31 Webcam Rx100 software RXS4V3 Coaxial telemetry ONLY. Not twisted pair. Application Notes Variable speed Pan/Tilt.
Rx 100 Interface Receiver Addendum to manual for the following domes: Chugai SMD-08II, SMD-12, SMD-12II, SMD-20 Sanyo VCC-9200P Star MD-800, MD-1200S, MD-1200H, MD-2000 Rx100 software RX1_S2V6 Application Notes The RX 100 provide the following functionality when controlling the above mentioned domes Variable speed Pan/Tilt, from 0.8deg/sec to 120deg/sec. Zoom/Focus, Autofocus following a Zoom In/Out. (Autofocus enabled with link fitted on J6 pin 1&2) 16 Full scene presets. 2 preset patrols. 4 alarm inputs.
BBV Rx100 Interface Receiver Addendum to manual for the following dome: Diamond/Ultrak KD6 Dome Rx100 software RX1_D1V5 up-the-coax telemetry only. Not twisted pair Application Notes Variable speed Pan/Tilt. Zoom/Focus, Iris override, Auto exposure ON/OFF 16 Full scene presets. 2 preset patrols. 4 alarm inputs driving to preset 1 - 4.
BBV Rx 100 Interface Receiver Addendum to manual for the following domes: VCL TP protocol Microsphere/Orbiter range. Rx100 software RX1_V1V10 Application Notes The RX 100 provide the following functionality when controlling the above mentioned domes Variable speed Pan/Tilt. Zoom/Focus, Autofocus following a Zoom In/Out. 16 Full scene presets. 2 preset patrols. Slow preset tour.
BBV Rx 100 Interface Receiver Addendum to manual for the following domes: Vicon Surveyor 2000 dome. Rx100 software RX1_V2V9 Application Notes The RX 100 provide the following functionality when controlling the above dome. Variable speed Pan/Tilt. Zoom/Focus, Autofocus with manual override. 16 full scene presets (additional presets available using dome's menu) 2 preset patrols 4 alarm inputs driving to preset 1 - 4. Additional commands: RUN TOUR 80. Pressing the AUTOPAN key will start the dome's Tour 80.
BBV Rx100 Interface Receiver Addendum to manual for the following domes: Videcon Dome Rx100 software RX1_V4V2 Application Notes The RX 100 provide the following functionality when controlling the above mentioned dome Variable speed Pan/Tilt. 16 Full scene presets. 2 RX100 preset patrols. Pattern Tour 1 learn and playback using AUTOPAN Privacy zone support IR Filter CUT using LIGHTS is link J6/1-2 fitted.
BBV Rx100 Interface Receiver Addendum to manual for the following camera: Videcon VCP451 Camera Rx100 software RX1_V5V1 Application Notes The RX 100 provides control of Zoom and Focus and Menu Access. Advanced Features Display MENU Tx400 Tx1000 ‘#’ 1 '#' WASH Tx1500 1 ’#’ DM DS/DS2/BX2 Mux *889 002 or *889 10 10 2 The camera and Rx100 are linked using RS485 for control and video for the camera signal.
BBV Rx100 Interface Receiver Addendum to manual for the following domes: Vista PowerDome Rx100 software RX1_V3V2 Application Notes The RX 100 provide the following functionality when controlling the above mentioned dome Variable speed Pan/Tilt. Zoom/Focus, Focus/Iris Override returning to auto after Zoom In/Out. 16 Full scene presets. 2 preset patrols. (PATROL1 = RX100 patrol and PATROL 2 = dome’s TOUR 02) Learned tour playback using AUTOPAN key. 5 minute datum/park driving to preset 1 or dome’s TOUR 2.
Appendix B - Trouble shooting guide. Symptom: No video from interface. Possible causes: Camera is not powered or not connected to ‘CAMERA’ BNC on interface. Check power and cabling. Interface is not powered. Check power. Video out not connected to ‘TELEMETRY’ BNC on interface. Check cabling. If the after following the above check list video still not present then remove both BNCs from the interface and connect together using a female/female barrel connector to check video path from camera to control point.
--- Blank for your notes --- Rx100 installation manual V1.16 01May08.
Other BBV products. Product Description camera desktop telemetry transmitter with BBV up-the-coax & TX300 Single 20mA telemetry, Pan/Tilt/Lens & Lights TX400 As TX300 inc Wash, Wipe, Autopan, 8 presets, preset patrol. TX400DC As TX400 including joystick for proportional Pan/Tilt control. 8 or 16 camera, 2 monitor telemetry transmitter. Up to 2 keyboards. up-the-coax and RS422 standard with options for alarm inputs TX1000 MK2 BBV and 20mA telemetry. Mid size matrix 16 – 96 camera, 8 monitor.