- Bay Technical Multiport Controllers Owner's Manual
To access the configuration mode of the multiport, connect a dumb
terminal (or a PC running a terminal emulation program) to the host
port: Port 5 of the 525H, Port 9 of the 528H and 529H, or Port 18 of
the 5218H. This port is factory configured at 9600 baud rate, 8 word
size, 1 stop bit, no parity, and XON/XOFF disabled.
If you do not have a dumb terminal or a terminal emulation program,
BayTech supplies a utility diskette which includes instructions to put
an IBM PC or compatible into a dumb terminal mode (see
Section
3.2
).
Send from this device the control character (factory default is
Control-T
- 14 Hex) followed by ASCII capital C (43 Hex). The
multiport should respond with the main configuration menu as shown
in
Section 6.1
. From this point on, configuration of the multiport will
be menu-driven. While in configuration mode, you may send
Control-S
to stop scrolling and
Control-Q
to continue scrolling.
The multiport will respond to the receiving of the control character and
capital C with an identification block and a configuration menu of the
options available, similar to the following for the 528H:
Bay Technical Associates
Model 528H Multiport Controller
Copyright 1986
Revision 2.06
Status......................................1
Set Serial Port Configuration...............2
Set Message Terminate Character.............3
Set Data Block Length.......................4
Set Control Character.......................5
Set Mode of Operation.......................6
Exit........................................X
Enter Request: