Technical Specifications

Voltage Protection Rating: 330 Volts Line-Neutral, Line-Ground, Neutral-Ground.
Electrical Mode Protection: Patented in-series Normal (L-N) and Common Mode (L-G, N-G, L,N,G).
Harmonic Attenuation: 40% typical reduction of odd-numbered current harmonics.
Power Factor Correction: Up to 30% average improvement.
EMI/RFI Noise Attenuation: Each path (Line, Neutral, Ground) bi-directionally ltered (patented):
Up to 100dB reduction on Line and Neutral, up to 60dB on Ground;
Frequency Range of 100 Hz to > 1GHz.
Electromagnetic Pulse Reduction: Blocks all unwanted current from pulses entering Line, Neutral and Ground
Surge Joule Rating: Series Mode Protection = Unlimited Joules of Energy Suppression
Duty Cycle: Tested independently to retain performance after 24 hours of constant 6000V,
3000 Amps surges without any degradation to unit or protected device.
Actual Clamping Voltage During
Surge (Typical) Under Load: Line-Neutral Voltage-120V RMS +/-10V. Neutral-Ground Voltage-0V RMS +/-10V.
Surge Line Current: Less than 0.0001 Amps over RMS.
Surge Withstand Rating: Severe Performance Test - 6000 Volts, 500 Amps Cat. A C62.41-1991 Ring-wave surge (at 90 degree
point of input sine wave, positive charge, L1, L2/PE) injected every 45 seconds with powered loads in
place for over 1260 injections in a 24 hour period with no degradation of device or attached load.
Surge Protection Life: Surge events do not damage patented circuit. Surge protection is always active.
Enclosure: ABS/PVC 94V0 with wall mounting feature
Storage Temp (ambient): 40° to 80° Fahrenheit, (4° to 27° Celsius)
Operating Temp (ambient): -40° to 104° Fahrenheit, (-40° to 40° Celsius)
Product Weight: 2.4 lbs, (1100 grams)
Product Dimensions: Length Width Height
6.5 inches 3.5 inches 3.3 inches
Bantam
Clean Power
Bantam PP3004A
Data Sheet
Model PP3004A-Product Specications
Electrical Features
Patented Technology that Protects
Line, Neutral and Ground
www.bantamcleanpower.com
Surge Protection Power Conditioning & Filter Stable Ground Reference
Harmonic Attenuation Power Factor Correction Ground Infiltration Protection
Input Connection: 6’ SJTOW 16 AWG cord set, NEMA 5-15P plug
Output Connection: Four (4) ltered NEMA 5-15R outlets
Circuit Protection: 3 amp thermal breaker, push-to-reset
Electrical Ratings
Input Voltage: 110-120 VAC Single Phase
Output Voltage: 110-120 VAC Single Phase
Max Output Voltage: 150 VAC
Output Current: 3 amps, VA Rating 360
Nominal Frequency: 50 to 60 Hz
Power Factor: 0.90
Safety Standard: MET Listed to UL and cUL Standards
C US
MET
Performance Metrics
Physical/Environmental
Intellectual Property
International Patents
6,166,458
6,288,917
8,223,468
Technology
Contact: Lodestone/Digilant, 4769 E. Wesley Drive, Anaheim CA 92807 • (714) 970-0900