User Manual
Table Of Contents
- 1 Introduction
- 2 Installation Requirements
- 3 Repeater Installation
- 3.1 Location Criteria
- 3.2 Standard Repeater Installation
- 3.3 Repeater with Fan Hood Installation
- 3.4 Five-Band System Installation
- 3.5 Grounding
- 3.6 Ensure Good EMV Protection
- 3.7 Fiber Optic Connection
- 3.8 External Alarm and Relay Connections
- 3.9 Power and Backup Battery
- 3.10 Power ON
- 3.11 Closing and Securing the Repeater
- 4 Opening a Session and Navigating GUI
- 5 MBF-40 Commissioning
- 6 MBF-40 Full GUI Description
- 7 Monitoring, Fault Sourcing and Maintenance
- Appendix A - US Specifications
- Appendix B - Canada Specifications
- Appendix C – F/O Cleaning Procedure
AXELL MBF -40 AMERICAS REPEATERS
PRODUCT DESCRIPTION AND USER’S MANUAL
56 Doc. No. 00071UM Rev. 3.2 © Axell Wireless Ltd
5 MBF-40 Commissioning
After the repeater is connected, it is identified by the OMU II via the Fiber connection
and the unit is commissioned from the OMU II. The commissioning process consists of a
few simple steps.
MBF-40 Setup and Commissioning consists of the following
1. Opening an OMU II session – for accessing the MBF-40 configuration window (via
OMU II)
2. Performing Optical Loss Adjustment on the connected MBF-40
3. Setting the required RF attenuation and gain levels on the remote MBF-40
4. Assigning the unit a recognizable name (according to its location)
5.1 MBF-40 Optical Loss Adjustment (OLA)
MBF-40 OLA is performed from the OMU II.
For MBF-40 remotes, the maximum compensation is increased to 26dB to support
shorter Fiber optic distances.
To perform MBF-40 OLA (via OMU II)
1. From the OMU II main window, click the Opto Adjust button.
Figure 5-1: OMU II Main window
Click to access
OLA screen
OMUII Main
window