User's Manual

AXELL D-MBR 3007-3008-PS NFPA REPEATER
PRODUCT DESCRIPTION AND USER’S MANUAL
32 UMCD00013 Rev 2.2 © Axell Wireless Ltd
5. Define the Downlink Channels:
Set the Start and Stop DL Frequency (MHz). (The Uplink Start and Stop
frequencies will be automatically allocated.)
Sub-band resolutions ranging between 200KHz and 1MHz can be allocated to a
narrowband or wideband filter. In this case, you will be prompted to select the
filter type
o Select the filter type and click Select and Return.
o Click Send at the top of the screen.
Set M
ax Gain: change the default value (maximum) according to the
measured/calculated input power and isolation measurements.
More information on DL sub-band parameters:
DL Set Ch. Max. Gain - Sets the power for the antennas. Recommended
Maximum Gain setting is approximately 16 dB less than the isolation between
the service and donor antennas.
DL Measured RSSI - measured DL signal.
DL Measured Ch. Gain - measured DL Gain (dB) for the selected sub-band.
DL Measured Ch. Power - measured Power (dBm) for the selected sub-band.
6. Set the Uplink parameters:
NOTE: The uplink channels are automatically allocated according to the downlink channel
definitions.
If the site NOISE LEVEL causes interference, adjust the noise level as follows:
Adjust the Gain Delta parameter – this sets the delta between the uplink and
downlink gain (so the uplink gain is relatively lower than the downlink gain.
Click Send.
Repeat the procedure until the desired coverage is achieved.
More information on DL sub-band parameters:
UL Gain ∆ - used for noise control. Sets the difference between UL and DL gain.
UL Measured Ch. Gain - measured UL Gain (dB) for the selected sub-band.
7. Click Send (top window area option).