Operation Manual

Error Messages
Controller B1 v3.0 16 Troubleshooting 95
16.2 Error Messages
Error Messages in Windows 2000
Please refer to the Windows 2000 documentation from Mi-
crosoft.
Error Messages in Windows NT
Error message: Controller-xx with I/O address <xxx> could
not be found
Possible cause: The position of the jumper that sets the I/O
address on the ISDN-Controller does not correspond to the
entry in the B1 Setup program; the I/O address is used by
another hardware device (a network adapter, for instance) or
the hardware is not installed.
Remedy: Check which I/O address is available in your com-
puter and set the jumper on the ISDN-Controller accordingly
(see the section Setting the I/O Address on page 14). Then
enter the new I/O address in the driver software by starting
the B1 Setup program from the AVM program group. Win-
dows NT must be restarted for this setting to take effect.
Error message: Installation Error. Interrupt <xx> not
available.
Possible cause: The AVM ISDN-Controller B1 v3.0 and anoth-
er hardware device (such as a sound card) are configured to
the same interrupt.
Remedy: Check which interrupt is available in your comput-
er, e.g. using the Windows NT Diagnostics program
(IRQ/Port Status). Then start the B1 Setup program from
the AVM program group and change the interrupt setting.
Windows NT must be restarted for this setting to take effect.