THERMOMETER gt-2021-3.
TABLE OF CONTENTS About Support Features Laser Safety Installing the App Pairing Mounting LED Indicator Surface & Internal Temp Troubleshooting Accuracy Check Cleaning Reset Procedure Distance to Spot Technical Specs IP Rating Warranty Certifications FCC Compliance IC Warning USER MANUAL 3 4 5 6 8 9 12 14 16 17 20 22 24 25 27 30 33 34 35 36 2
ABOUT The ZippyYum Thermometer is a super-awesome, one-of-a-kind, bluetooth, contactless, infrared thermometer. It even supports an external probe. The probe jack is compatible with standard K-type thermocouple connector probes. An internal battery charged with a standard USB-C connector powers the thermometer. All ZippyYum thermometers are compatible with both iOS and Android phones and tablets.
SUPPORT ZippyYum offers free support for our hardware and apps. ONLINE RESOURCES I f you need help with your thermometer, please visit www.zippyyum.com for support resources including a knowledge base. IN-APP RESOURCES You can also access the knowledge base in the Help & Support area from the main menu of any ZippyYum app. CONTACT US To reach our support team, please use the Help & Support area from the main menu of any ZippyYum app. You can also email us at support@zippyyum.
FEATURES Infrared sensor USB-C charging port Laser indicator K-type thermocouple probe jack LED indicator & reset button USER MANUAL 5
LASER SAFETY The ZippyYum Thermometer contains a laser pointer compliant with FDA 21 CFR 1040.10, subchapter J. Please refer to the technical specifications for additional details. WARNING! Avoid directly exposing eyes to the thermometer’s laser as this may result in eye damage. Never point the laser at another person. When using model WTB4010-M to take a person’s forehead temperature the app will automatically disable the laser. Always keep thermometer out of the reach of children.
01.
INSTALLING THE APP Your ZippyYum Thermometer must be paired with the GoTemp app on an iOS or Android device before being used. To install the app, tap below or visit: www.zippyyum.com/apps TAP TO INSTALL Once the GoTemp app is installed, log into the app using your login credentials. Now you’re ready to pair.
PAIRING PRO TIP Your thermometer’s unique identifier, also known as its MAC address, is printed on the back of the device as shown below. You may need it during pairing.
PAIRING Your ZippyYum Thermometer arrives powered OFF. Flip it on over and use a thin tool like a paper clip to flip the recessed switch to the ON position. PRO TIP The power switch is recessed for a reason! The thermometer is meant to be left in the ON position at all times. It will automatically go into power-saving mode when not in use.
PAIRING The GoTemp app will automatically connect to your thermometer if only one thermometer is detected. If there are multiple thermometers, you’ll see a list of options. Available thermometers will show as “THERM_##” with ## being the last two digits of its MAC address. The LED indicator will blink once a thermometer is selected. The ZippyYum Thermometer will pair automatically or prompt you for a pairing code. If prompted, enter code ‘123456’ in the app.
MOUNTING The ZippyYum Thermometer attaches to any phone, case, or tablet with a flat back using a univeral mounting plate. Simply clean the area thoroughly (we recommend isopropyl alcohol), peel the adhesive backing, and stick the plate on your device. Make sure the raised bar on the mounting plate is horizontal.
MOUNTING Next, align the raised tabs on the mounting plate with the notches in the back of your ZippyYum Thermometer. Place the thermometer down onto the mounting plate and slide it to the side until it clicks.
LED INDICATOR The ZippyYum Thermometer has an LED indicator to show battery information and pairing connectivity status to its device.
02.
SURFACE & INTERNAL TEMP The infrared thermometer measures surface temperature. Make sure to mix items prior to taking an infrared temperature to get an accurate reading. When internal temperatures are more critical for items like meat cooking on a grill, use the thermometer’s probe jack to take an internal probe temperature. Cold Holding Example: Use your free, gloved hand to mix or move the top layer of veggies in a food pan to get the internal temperature using infrared.
TROUBLESHOOTING If your temperatures seem off, please follow these troubleshooting steps prior to contacting our support team. Start by throroughly cleaning the thermometer following the steps outlined in this guide. A dirty infrared lens is the most common cause of inaccurate infrared temperatures. If multiple items are temping outof-range, verify your equipment is turned on and set to the proper temperature.
TROUBLESHOOTING Make sure food is not covered, the ZippyYum thermometer can’t measure through glass or plastic. Steam, dust, smoke, and vapor can obstruct Scancase’s sensors. Avoid high humidity environments with condensation when using infrared. Avoid measuring reflective surfaces (like aluminum wrapping) unless a matte surface is on top (like a label).
03.
ACCURACY CHECK QUICK ACCURACY CHECK To quickly check the infrared thermometer, fill a cup with ice and add enough cold water just to fill in the gaps between the ice. Let the ice water sit for 2 minutes, then stir thoroughly. Hold the thermometer about 6” to 8” directly above the ice and take an infrared temperature. Make sure the thermometer is pointed straight down and not angled, otherwise you may be taking the cup’s temperature instead of the ice water. The thermometer should read about 32.0°F or 0°C.
ACCURACY CHECK REMINDER! The only way to check the accuracy of an IR thermometer is to verify it against a known temperature. Using a probebased thermometer will produce different results and should not be used to check the thermometer’s IR accuracy. COMPLETE ACCURACY CHECK For a more detailed accuracy check procedure for both hot and cold temperatures, please visit the ZippyYum knowledge base. You can access the knowledge base in the Help & Support area from the main menu of any ZippyYum app.
CLEANING The ZippyYum Thermometer’s sensors should always be kept free of dirt, dust, moisture, smoke, and debris. WARNING! Do not submerge the thermometer or wash in a dishwasher. To clean the body of the thermometer, moisten a cloth with a water-based mild detergent and wipe the device.
CLEANING A dirty infrared lens is the most common cause of inaccurate infrared temperatures. To clean the infrared lens, lightly moisten a cotton swab with water and insert and swirl it in the lens opening to clean any debris. Repeat with a clean cotton swab until it comes out clean. Finish with a dry cotton swab to dry the lens.
RESET PROCEDURE To reset the thermometer, simply use your finger to press the reset button located on the bottom area of the front of the thermometer. The LED indicator is also the reset button. The thermometer will blink orange 5 times to confirm the reset.
DISTANCE TO SPOT The field of view (distanceto-spot) is the area of where temperature is being measured via infrared. The distance you hold the thermometer away from the product determines the dimensions of this area. The further away from the product, the larger the area being measured. The laser helps indicate where the thermometer is measuring. Hold the thermometer about 6” away from the item you want to measure for accurate temperatures. Spot Diameter Distance 1” (25mm) 11.
04.
OTHER LASER BATTERY OPERATING CONDITIONS TECHNICAL SPECS Storage Temp 14°F to 113°F -10°C to 45°C Operating Temp 50°F to 104°F 10°C to 40°C 10% to 90% Humidity Charging Voltage ≤100mA 5V Bluetooth Power 0 dBM Capacity Voltage 400 mAH 3.
THERMOMETER TECHNICAL SPECS Temperature Unit °F and °C IR Measurement Range -94°F to 716°F -70°C to 380°C Probe Measurement Range -454°F to 2500°F -270°C to 1372°C Actual probe measurement may be limited by the range of the probe. Please refer to your probe’s documentation prior to use. Never use a probe to measure items outside the listed temperature range. Repeatability Within accuracy Response Time 1 second Probe Resolution 0.25°F or 0.
TECHNICAL SPECS THERMOMETER IR Accuracy at Room Temp (77°F or 25°C) 2°F or ±1°C ± when object is 32°F to 140°F ±4°F or ±2°C when object is <32°F or >140°F IR Emissivity 0.95 (preset, but adjustable) IR Measurement Distance 1” to 12” 2.
IP RATING The ZippyYum thermometer is rated IP67 (maximum depth of 1 meter up to 30 minutes) under IEC standard 60529. This rating is for the thermometer only. Please refer to the owner’s manual for your iOS or Android device for its waterproof rating. Complete protection is not guaranteed under all conditions. Read this guide for proper use of Scancase. Malfunctions due to improper handling by the user are not covered under warranty.
05.
WARRANTY ZippyYum warrants the ZippyYum Thermometer, at the time of its sale by ZippyYum, is free of defects in material, workmanship, and component failures under normal and proper use for a period of one (1) year from date of delivery. This warranty applies worldwide. ZippyYum’s only obligation is to correct such defects by repair or replacement, at its option, if within the warranty period and the product is returned prepaid by the customer.
WARRANTY ... or failure to perform this warranty obligation. ZippyYum’s liability on any claim for damages arising in connection with the manufacture, sale, installation, delivery, or use of the ZippyYum Thermometer shall never exceed the purchase price of the product. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort, or otherwise.
CERTIFICATIONS The ZippyYum thermometer conforms to the following standards: UL LISTED FOR UL2333 Infrared Thermometers - E1481655 UL EPH CLASSIFIED FOR ANSI/NSF 2 Food Service Equipment - SA44549 FCC CFR47 PART 15 SECTION 15.
FCC COMPLIANCE This device complies with Part 15 of the FCC rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or change to this equipment.
IC WARNING This device complies with Industry Canada licenseexempt RSS standard(s). Operation is subject to the following two conditions: 1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: 1.