CALIBRATION due 07 90 0- 09 08 0 Instruction Manual 4 5 3 40 2 20 1 0 60 10 2 0 lbf/in bar 07900-09080 Speed Fastening Applications B ro a c h L o a d Te s t P o w e r To o l 80 6 0 7
Contents Safety Rules 4 Tool Specifications 5 Intent of Use 5 Putting into Service Air Supply Loading the Tool Cursor Nose Equipment Operating Procedure 6 6 6 6 7 Air Pressure Graph vs Broach Load 8 Mandrel Life Table 9 Warranty Avdel UK Limited installation tools carry a 12 month warranty against defects caused by faulty materials or workmanship, the warranty period commencing from the date of delivery confirmed by invoice or delivery note.
Safety Rules This instruction manual must be read with particular attention to the following safety rules, by any person operating this tool. 1 Do not use outside the design intent. 2 Do not use equipment with this tool/machine other than that recommended and supplied by Avdel UK Limited. 3 Any modification undertaken by the customer to the tool/machine or any equipment supplied by Avdel UK Limited or their representatives, shall be the customer’s entire responsibility.
Specification Air Pressure Maximum 7 bar Free Air Volume Required @ 5.5 bar 1.72 litres Noise Level Less than 70 dB(A) Weight Without nose equipment 3.0 kg Vibration Less than 2.5 m/s2 Intent of Use This particular test tool is to be used solely with Avdel® speed fasteners supplied by Avdel®. The precise list of fasteners appears in the mandrel life table page 9.
Putting into Service Air Supply This tool operates with compressed air at a maximum pressure of 7 bar. We recommend that you temporarily make use of the air supply set up for your actual placing tool with precautions as described in the instruction manual for your placing tool. L o a d i n g t h e To o l The procedure for loading the tool with fasteners and for fitting the nose equipment to the tool are integral. Refer to the instruction manual for your specific placing tool EXCEPT FOR 1.
Putting into Service O p e r a t i n g P ro c e d u r e READ THE SAFETY INSTRUCTIONS page 4 carefully. • • • • • • • • • • Connect the test tool to the air supply. Set the gauge on the test tool to zero actuating the trigger to ensure a true reading. Fit the exact same nose equipment to the test tool as you intend to use on the tool you will be using to place the fasteners in your application and as recommended in the instruction manual for your specific tool.
A i r P re s s u re G r a p h v s B ro a c h L o a d 8
489 110 / 50000 2.5mm Avtronic 50000 42600 - 50000 - 50000 50000 50000 - 50000 - 3/32 Grovit 2.5mm Avsert 4-40 UNC Avsert 1/8 Avlug 2.8mm Avtronic 1/8 Chobert 1/4 Chobert 6mm Briv 3/16 Briv (St.Steel) 3/16 Grovit 3/16 Chobert 3/16 Briv 5/32 Briv (St.Steel) 5/32 Grovit 5/32 Chobert 4.8mm Rivscrew 4.0mm Rivscrew 5/32 Briv 3.5mm Rivscrew 1/8 Briv (St.
Notes 10
Declaration of Conformity We, Avdel UK Limited, Watchmead Industrial Estate, Welwyn Garden City, Herts, AL7 1LY declare under our sole responsibility that the product: Model: Broach Load Test Power Tool Serial No. ................................................
GERMANY SOUTH KOREA Acument Australia Pty Ltd. Avdel Deutschland GmbH Acument Korea Ltd. 891 Wellington Road Klusriede 24 212-4, Suyang-Ri, Rowville, Victoria 3178 30851 Langenhagen Silchon-Eup, Kwangju-City, Tel: +61 3 9765 6400 Tel: +49 (0) 511 7288 0 Kyunggi-Do, Korea, 464-874 Fax: +61 3 9765 6445 Fax: +49 (0) 511 7288 133 Tel: +82 31 798 6340 Email: info@acument.com.au Email: AvdelDeutschland@acument.