Solution & Interoperability Test Lab Application Notes
©2004 Avaya Inc. All Rights Reserved.
7 of 10
HP-PoE.doc
Steps Description
3.
• Connect several Avaya IP Telephones as shown in Figure 1 to Ethernet ports on the
switch. In this example, Avaya 4620, 4610SW, and 4602SW IP telephones were
connected to ports 1-3 respectively.
• Verify that the telephones are powered and booting by inspecting their displays.
• Check inline power status of the switch ports. In the example below, all three IP
telephones were in the idle state (no active calls).
HP ProCurve 2626-PWR#show power-management brief
Status and Counters - Port Power Status
| Power Configured Detection Power
Port | Enable Priority Type Status Class
----- + ------- -------- ---------------- ----------- ------
1 | Yes Critical Delivering 3
2 | Yes Critical Delivering 2
3 | Yes Critical Delivering 1
4 | Yes Low Searching 0
----- + ------- -------- ---------------- ----------- ------
HP ProCurve 2626-PWR#show power-management 1-3
Status and Counters - Port Power Status for port 1
Power Enable : Yes
Priority : Critical Configured Type :
Detection Status : Delivering Power Class : 3
Over Current Cnt : 0 MPS Absent Cnt : 1
Power Denied Cnt : 0 Short Cnt : 0
Voltage : 500 dV Current : 140 mA
Power : 7000 mW
Status and Counters - Port Power Status for port 2
Power Enable : Yes
Priority : Critical Configured Type :
Detection Status : Delivering Power Class : 2
Over Current Cnt : 0 MPS Absent Cnt : 1
Power Denied Cnt : 0 Short Cnt : 0
Voltage : 500 dV Current : 67 mA
Power : 3350 mW
Status and Counters - Port Power Status for port 3
Power Enable : Yes
Priority : Critical Configured Type :
Detection Status : Delivering Power Class : 1
Over Current Cnt : 0 MPS Absent Cnt : 0
Power Denied Cnt : 0 Short Cnt : 0
Voltage : 500 dV Current : 64 mA
Power : 3200 mW