User's Manual

FAS; Reviewed:
RS 7/18/03
Solution & Interoperability Test Lab Application Notes
©2004 Avaya Inc. All Rights Reserved.
8 of 11
FoundryILP.doc
1.
Disable inline power to port 1 and verify that the telephone has lost power
FES2402 Switch(config)#interface eth 1
FES2402 Switch(config-if-e100-1)#no inline power
FES2402 Switch(config-if-e100-1)#show inline power
Power Supply: total capacity is 480000 of which 457600 is currently available
power has been successfully allocated 64 times and rejected 0 times
Port Detection Class Power Enable Power
-------------------------------------------------------------
01 Unknown Unknown OFF No
02 802.3AF-PD Class2 ON Good
03 802.3AF-PD Class3 ON Good
04 Unknown Unknown OFF No
05 Unknown Unknown OFF No
06 Unknown Unknown OFF No
07 Unknown Unknown OFF No
08 Unknown Unknown OFF No
09 Unknown Unknown OFF No
10 Unknown Unknown OFF No
11 Unknown Unknown OFF No
12 Unknown Unknown OFF No
13 Unknown Unknown OFF No
14 Unknown Unknown OFF No
15 Unknown Unknown OFF No
16 Unknown Unknown OFF No
17 Unknown Unknown OFF No
18 Unknown Unknown OFF No
19 Unknown Unknown OFF No
20 Unknown Unknown OFF No
21 Unknown Unknown OFF No
22 Unknown Unknown OFF No
23 Unknown Unknown OFF No
24 Unknown Unknown OFF No
FES2402 Switch(config-if-e100-1)#
Note that the Detection column indicates that inline powering is not configured for port 1.
2. Enable inline power for port 1 and verify that the telephone receives power.
FES2402 Switch(config-if-e100-1)#inline power
FES2402 Switch(config-if-e100-1)#exit
FES2402 Switch(config)#
Table 2 defines the column headings displayed as a result of the show inline power command.