main PN and the System G, and configure the T1 (DS1) on the main PN using add ds1 command
via SAT, as follows:
add ds1 c15 Page 1 of 2
DS1 CIRCUIT PACK
Location: 01C15 Name: synch for main PN
Bit Rate: 1.544 Line Coding: b8zs
Line Compensation: 1 Framing Mode: esf
Signaling Mode: isdn-ext
Interface Companding: mulaw
Idle Code: 11111111
Slip Detection? n Near-end CSU Type: other
Here the T1 board in slot 01C15 is connected to a T1 board in another Avaya Media Gateway.
4.2.2. Remote PN Synchronization
As stated in Section 4.2, connect the External Clock port on the IPmux-14 to a T1 from public
network (a common source to the main PN).
To verify that the remote PN is deriving synchronization from the DS1-C facility on the DS1
Converter board, enter the test tone-clock x long command on SAT, where x is the location of the
tone-clock board on the remote PN. In the following example, the tone-clock board for remote PN is
11a. Verify that the test number 150 is passed.
test tone-clock 11a long
TEST RESULTS
Port maintenance Name Alt. Name Test No. Result Error Code
11AXX07 ETR-PT 42 PASS
11AXX07 ETR-PT 43 PASS
11AXX08 ETR-PT 42 PASS
11AXX08 ETR-PT 43 PASS
11A TDM-CLK 148 PASS
11A TDM-CLK 150 PASS
11A TDM-CLK 151 PASS
11A TDM-CLK 574 PASS
11A TONE-PT 90 PASS
11A TONE-PT 40 PASS