Setting New Code for the AV-706, 707
To enter User Programming mode ‘Hold Down’ the '8' (program) key.
The three Rightmost LEDs start blinking; enter the Master User Code (factory default
1 2 3 4
) followed by # (Enter). The upper line displays 'User Programming', the lower
line is cleared and a blinking cursor appears.
The Leftmost two LEDs will start blinking indicating that a ‘location’ is expected. In
this case, location means ‘User Code’ index to be modified, erased or programmed.
User Index means User Number 1-8, as system contain eight different user codes.
Enter a two digits number from 01 to 08 (2 digits required). After the index had been
entered (the ‘location’), the upper line is
cleared, the blinking cursor moves to the
beginning of the line, three Rightmost LEDs
start blinking indicating that data is expected
(in this case the new User Code).
Enter a one to six digits code. Key '*'
corrects the input press, as backspace or
Hold Down key '9' (reset) to cancel the
input.
Press '#' key for confirm.
The control panel will verify that the new
code is not in use by other user (if that
happens you'll be notified) and respond by
displaying the code. At any time after the
control panel response, you can start typing a
new index (there is no need to wait for the
announcement to disappear).
To erase an existing code: Enter user index
number (01, 02, 03....), hold down
simultaneously keys '*' and ' #', followed by
#, E (erased) will be displayed.
The Master (code number 01) cannot be erased. Type ‘99’ followed by # to exit.
Setting Follow-Me Telephone at AV-706, 707
To display the Follow-Me telephone number; hold down '6' (type '#' for faster display)
and the control panel will display the number (or the 'empty' announcement if there is
no telephone number currently programmed).
To program the Follow Me telephone number Hold Down twice the '6' key. The three
Rightmost LEDs blink, indicating that the keypad waits for input.
*
7
4
1
0
8
5
2
#
9
6
3
Siren
Shunt
Display Status
Delay
Delete
Chime
Test Program Reset
Shunt
Telephne
ARMED STATUS
SHUNT FIRE
SYSTEM DISARMED
1 2 3 4 5 6 6 7 *
12:00