Owner's Manual Split type wall mounted air-conditioner read this owner's manual carefully and hly before operating the unit! of this manual for future reference.
Safety Precautions o-u. 1 Salesforce 6 Names of each part 8 Clearance 9 Troubleshooting o-u 10 Notices for installation 12 Install indoor unit 15 Install outdoor unit 18 Check after installation and test operation Note: All the pictures In this manual are Just schematic diagrams, the actual Is the standard.
Incorrect installation or operation by not following these instructions may cause harm or damage to people, properties, etc. | The seriousness is classified by the following indications. J WARNING 4 CAUTION & This symbol indicates This symbol indicates the the possibility of death possibility of injury or or serious injury. damage to properties.
The air conditioner must be grounded. Incomplete grounding may result in electric shocks. Si Do not connect the earth wire {o the gas pipeline, water pipeline, lightning rod, or telephone earth wire. Pull out the plug {or cut off the main power switch) when the unit is not in use for long time so as to ensure safety. 49 ® Before the connector Is plugged In, please make sure that there is no dust on it and that it is plugged fully in place.
~ Don't install air conditioner In a place where there Is flammable gas or liquid. The distance between them should above 1m. Don't use liquid or corrosive cleaning agent wipe the alr conditioner and sprinkle water or other liquid either. J] = Don't attempt to repair the alr conditioner by yourself. | QOD Incorrect repairs may cause _F od electric or fire. Contact a 7 Doing this may case electric qualified service technician It may cause fire. shock or damage to the unit. for all service requirement.
This product contains fluoridated greenhouse gases. Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to [2088]. This means that this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be [2088] times higher than 1 kg of COz, over a period of 100 years.
CAUTION & Don’t open the windows and doors for long time when the air conditioner is running. , or heating| capacity will be weakened. Don’t stand on the top of the outdoor unit or place heavy things on it. Don’t use the air conditioner for other purposes, such as drying clothes, preserving foods, etc. This cloud cause personal Injuries or damage the unit. Don't apply the cold air to the body for a long time. It will deteriorate your physical conditions and cause health problems.
e sons of unit can 1 * Within the temperature range provided in following table, the air conditioner may stop running and other anomalies may ares. misapply to T1) Cooling Outdoor misapply to T3) Indoor <18C >24T Heating Outdoor 27C # When the temperature is too high, the air conditioner may activate the automatic protection device, so that the air conditioner could be shut down.
Emergency operation * If the remote controller is lost or broken, use force switch button to operate the air conditioner. * If this button is pushed with the unit OFF, the air conditioner will operate in Auto mode. # If this button is pushed with the unit ON, the air conditioner will stop running. rfl i adjustment 1. Use up-down swing and left-right swing buttons on the remote controller to adjust the airflow direction. Refer to the operation manual of the remote controller for detail. 2.
Air inlet grille Power cable fi Pipe protection — or Air outlet Air inlet > Air outlet grille Connecting Drain hose Air outlet Note: All the pictures in this manual are just schematic diagrams, the actual is the standard. Plug, WIFI function, Negative-ion function, and Vertical and horizontal swing function both are optional,the actual unit shall prevail.
Warming ® Before the cleaning of the air conditioner, it must be shut down and the electricity must be cut off for more than 5 minutes, otherwise there might be the risk of electric shocks, # Do not wet the air conditioner, which can cause an electric shock. Make sure not to rinse the air conditioner with water under any circumstances.
lean the air fleeter H Mount the Liter 1. Reinstall the dried filter in reverse order of removal, then cover and lock the panel. Check before use 1. Check whether all the air inlets and outlets of the units are unblocked. 2. Check whether there is blocking in the water outlet of the drain pipe, and immediately clean it up if any. 3. Check the ground wire is reliably grounded. 4. Check whether the remote control batteries are installed, and whether the power is sufficient. 5.
Phenomenon # Has the power been shut down? © |s the wiring loose? Air conditioner can « |3 voltage too high or too low (measured by professionals) not operate at all.
01] nt Notices um Before installation, please contact with local authorized maintenance center, if units not installed by the authorized maintenance center, the malfunction may not solved,due to dis commodious contact. H The air conditioner must be installed by professionals according to the national wiring rules and this manual. | To move and install air conditioner to another place, please contact our local special service center.
afe retirements ® Be sure to use the rated voltage and air conditioners dedicated circuit for the power supply, and the power cord diameter must meet the national requirements. ® When the maximum current of air conditioner is 216A, it must use the air switch or leakage protection switch equipped with protection devices.
requirements for operations al raised height ™ When carrying out installation at 2m or higher above the base level, safety belts must be worn and ropes of sufficient strength be securely fasten to the outdoor unit, to prevent falling that could cause personal injury or death as well as property loss. ing Requirements ® The air conditioner is the type I electrical appliance and must ensure a reliable grounding.
Space to the wall the wall 20¢m above aboveboard Mounting plate 1. The wall for installation of the indoor unit shall be hard and firm, se as to prevent vibration. 2. Use the type screw to fasten the peg board, horizontally mount the peg board on the wall, and ensure the lateral horizontal and longitudinal vertical. 3. Pull the peg board by hand after the Installation, to confirm whether It Is solid. \. Wall through Hole 1.
Route of Pipeline 1. Depending on the position of the unit, the piping may be routed sideways from the left or the right { Fig 1 ), or vertically farm the back( Fig 2 }{depending on the pipe length of the indoor unit). In the case of sideways routing, cut off the outlet cutting stack of the opposite side. 2. The power cord may be routed separately from the piping. Cut off the outlet cutting stock and then run the power cord through the hole, keeping the remaining part as a protection from rodents.
1. Hang the indoor unit on the peg board, and move the unit from left to right to ensure that the hook Is properly positioned In the peg board. 2. Push toward the lower left side and the = upper right side of the unit toward the peg a= board, until the hook is embedded in the wp Hg slot and makes a click” sound. ring diagram # If your air conditioner is provided with interconnection cord, the wiring of the indoor unit Is connected In the factory, there Is no need of connection.
ANSI wing utd nit install ~ Space to the obstruction Air in side stem Above Space to the obstruction E Installation outdoor unit bolt Ones | Space to the abstraction mn Oa pope A(mm) | B(mm) : 430 280 T(E 400 200 TER he 500 260 | 460 260 wz 540 280 Loft Installation foot Installation fest 540 280 \ _Triennial , 545 300 hO 545 35 ' 540 325 AT A 540 335 TT + 630 350 Aleutian | 675 408 4 Install the connection pipe Connect the Outdoor Unit with Connecting Pipe: fs Aim the counter-bore of the connecting pipe at
= 1.Loosen the screws and remove E-parts cover from the unit. 2.Connect the cables respectively to the corresponding terminals E-parts cover of the terminal board of the outdoor unit (see the wiring diagram), and If there are signals connected to the plug, Just conduct butt joint. = 3.Ground wire: Remove the grounding screw out of the electric L HB bracket, cover the grounding wire end onto the grounding screw and screw It Into the grounding hole. 4.Fix the cable reliably with fasteners (Pressing board).
— expelling the alr ] . Y Outdoor ult refrigerant discharging method After the pipe side connection Is complete, proceed as follows. me 7 RRR tle temporary fastened The reinstalling tore nut by half urn. by fate same aa tat Fulfillment Check that all Indoor Tho door uh. Spindles of rp | Quid end and of oath ar faa Y the other two ends. of air leavings.
Check after installation % Electrical Safety Check 1. If the supply voltage is as required. 2. If there is any faulty or miss connection in each of the power, signal and grounding wires. 3. If the grounding wire of the air conditioner is securely grounded. Y Installation Safety Check 1. If the Installation Is secure. 2. If the water drain Is smooth. 3. If the wiring and piping are correctly Installed. 4. Check that no foreign matter or tools are left Inside the unit.