User's Manual

Table Of Contents
8 Programming
- 25 -
LIMM&SA0-00.fm
8PROGRAMMING
The dip switches can only be programmed by authorised personnel; program-
ming is only possible when the receiving unit is not powered and the battery has
been removed from the transmitting unit.
The incorrect closure of the transmitting and the receiving unit can compromise
the seal between the casings and thereby the protection degree from dust and
water.
8.1 Programming the transmitting module
To change the programming set in the radio module, it is necessary to open the transmitting
unit.
The group of eight dip switches located on the radio modules is used to program some functions
and set the working frequency. The programming set in the other group of four dip switches
must never be modified.
For the correct functioning (see paragraph 1.7), the group of 8 dip switches (ex-
cluding DIP 1) for the radio modules E16STXEU_ and E16SRXEU_ must be set in
the same way.
Set the group of 8 dip switches as described below:
Group of
8 dip switches
Pay particular attention when closing the unit at the end of the operation.
MK transmitting unit MJ transmitting unit
DIP MODULE STATE FUNCTION
1E16STXEU_
ON
The transmitting unit never switches off automatically
OFF
If the transmitting unit stays switched on without any movement
commands activated, it switches off after approx. 3.5 minutes.
2
a
a. With MK12 transmitting units this dip switch must be at ON.
E16STXEU_
ON
Deactivation of low battery warning from horn on machine
OFF
Activation of low battery warning from horn on machine
3-7 E16STXEU_ ON/OFF
See paragraph 1.7 and paragraph 8.5
8E16STXEU_
ON
Manual selection mode of the frequencies using DIP 3 - DIP 7
(see paragraph 8.5)
OFF
DO NOT USE