Technical information

46
Bay Form
Factor
Height Front
Access
Usage Part
Number
Description RPM Height Bays
Supported
Max.
Qty.
A
133 mm
(5.25”)
HH
1
Yes Open
Ultra2 Hard Disk Drives (HDD)
1
B
133 mm
(5.25”)
HH
1
Yes Open 36L9744
Netfinity 9.1 GB Wide Ultra2 SCSI
Hot-Swap SL HDD
7200 SL C...H 6
-
133 mm
(5.25”)
SL Yes
IDE CD-
ROM
36L9745
Netfinity 18.2 GB Wide Ultra2 SCSI
Hot-Swap SL HDD
7200 SL C...H 6
-
89 mm
(3.5”)
SL Yes Diskette 36L9748
Netfinity 9.1 GB 10K-3 Wide Ultra2
SCSI Hot-Swap SL HDD
10,000 SL C...H 6
C...H HS SL
2
Yes Open 36L9749
Netfinity 18.2 GB 10K-3 Wide
Ultra2 SCSI Hot-Swap SL HDD
10,000 SL C...H 6
1. Two half-high (HH) bays can be combined to support a single full-high
(FH) device. Installation of devices in Bays A or B requires Netfinity Hot-
Swap Power Supply Expansion Kit (P/N 37L6881) and at least one Netfinity
250 W Hot-Swap Redundant Power Supply (P/N 33L3760). Installation of
HDDs in Bays A and B also requires Netfinity Media Bay Conversion Kit (P/N
10K2340).
2. Two slim-line (SL) bays (C/D, E/F, G/H) can be combined to support a
single half-high (HH) device.
Ultra160 Hard Disk Drives (HDD)
1
37L7201
Netfinity 9.1 GB Ultra160 SCSI Hot-
Swap SL HDD
7200 SL C...H 6
37L7202
Netfinity 18.2 GB Ultra160 SCSI
Hot-Swap SL HDD
7200 SL C...H 6
37L7203
Netfinity 36.4 GB Ultra160 SCSI
Hot-Swap SL HDD
8
7200 SL C...H 6
37L7204
Netfinity 9.1 GB 10K-4 Ultra160
SCSI Hot-Swap SL HDD
9
10,000 SL C...H 6
37L7205 Netfinity 18.2 GB 10K-4 Ultra160
9
10,000 SL C...H 6
37L7206
Netfinity 36.4 GB 10-K Ultra160
SCSI Hot-Swap SL HDD
9
10,000 SL C...H 6
Non-Hot-Swap Internal Hard Disk Drives (HDDs)
20L0553 9.1 GB Wide Ultra2 SCSI HDD
2
7200 SL A, B
2
1
20L0554 18.2 GB Wide Ultra2 SCSI HDD
2
7200 SL A, B
2
2
Associated Options
10K2340
Netfinity Media Bay Conversion
Kit
3
- - A/B 1
33L3760
Netfinity 250 W Hot-Swap
Redundant Power Supply
- - - -
37L6881
Netfinity Hot-Swap Power Supply
Expansion Kit
- - - -
External Storage Expansion
Units
4
Form
Factor
35301RU
Netfinity EXP200 Storage
Expansion Unit
5
Rack
(3U)
37L5857
Netfinity EXP200 Rack-to-Tower
Conversion Kit
-
37L0075
Netfinity EXP200 350 W
Redundant Power Supply
-
35311RU
Netfinity EXP300 Storage
Expansion Unit
6, 9
Rack
(3U)
09N7296
Netfinity EXP300 Rack-to-Tower
Conversion Kit
-
35601RU
Netfinity FAStT EXP500 Storage
Expansion Unit
7
Rack
(3U)
1. Mixing Ultra2 and Ultra160 HDDs on a single Ultra160 SCSI channel will result in all HDDs operating at Ultra2
bus speeds.
2. Requires Netfinity Media Bay Conversion Kit (P/N 10K2340), Netfinity Hot-Swap Power Supply Expansion Kit
(P/N 37L6881) and Netfinity 250 W Hot-Swap Redundant Power Supply (P/N 33L3760).
3. Netfinity Media Bay Conversion Kit (P/N 10K2340) converts two half-high 5.25” removable media bay into two
non-hot-swap HDD bays. Requires installation of both Netfinity Hot-Swap Power Supply Expansion Kit (P/N
37L6881) and at least one Netfinity 250 W Hot-Swap Redundant Power Supply (P/N 33L3760).
4. Select an optional SCSI controller then refer to Appendix D: Cables-Storage Units-Controllers to confirm the
controller supports the desired External Storage Expansion Unit and to select a supported cable. For HDD or
other expansion unit options, see the specific expansion unit section.
5. Netfinity EXP200 includes a single 2 M Ultra2 SCSI cable and single hot-swap 350W power supply and power
cord. Optional hot-swap Netfinity EXP200 350W Redundant Power Supply (P/N 37L0075) includes an additional
power cord.
6. Netfinity EXP300 includes a single 2 M Ultra2 SCSI cable and dual hot-swap 500W redundant power supplies,
each with its own power cord.
7. Netfinity FAStT EXP500 Storage Expansion Unit (P/N 35601RU) includes dual hot-swap 350W power supplies,
each with its own power cord.
8. Planned availability of June 1, 2000.
9. Planned availablilty of June 30, 2000.
B
CD-ROM
Diskette
Hot-Swap
(HS)
A
Removable Media (RM)
E
C
FG
H
D
A
B
CD-ROM
Diskette
Removable Media (RM)
Tower Model View
Rack Model View
For clarity purposes, bay labels in
these diagrams are for reference by
the accompanying tables and are not
the actual labels. Refer to the
documentation shipped with the
system for further details on actual
labels.
C
D
E
F
G
H
Hot-Swap (HS)