- Notices
- Chapter 1: Product Introduction
- Chapter 2: Getting Started
- Chapter 3: Web-based User Interface
- 3.1 Web-based user interface
- 3.2 Dashboard
- 3.3 Sensor
- 3.4 System Inventory
- 3.5 FRU Information
- 3.6 Logs & Reports
- 3.7 Settings
- 3.7.1 Captured BSOD
- 3.7.2 Date & Time
- 3.7.3 External User Services
- 3.7.4 KVM Mouse Setting
- 3.7.5 Log Settings
- 3.7.6 Manage Licenses
- 3.7.7 Media Redirection Settings
- 3.7.8 Network Settings
- 3.7.9 PAM Order Settings
- 3.7.10 Platform Event Filters
- 3.7.11 NIC Management
- 3.7.12 Services
- 3.7.13 SMTP Settings
- 3.7.14 SSL Settings
- 3.7.15 System Firewall
- 3.7.16 User Management
- 3.7.17 Video Recording
- 3.7.18 IPMI Interfaces
- 3.7.19 Fan Control
- 3.7.20 PSU Cold Redundancy
- 3.8 Remote Control
- 3.9 Image Redirection
- 3.10 Power Control
- 3.11 Locator LED
- 3.12 Maintenance
- Appendix
ASUS ASMB11-iKVM
A-9
Sensor No. Sensor Name Sensor Type Sensor Type Code Sensor Value or Event Type
0xEB(235) PSU3 AC Lost 0x08 Power Supply Discrete(0x6F)
0x01: Presence Detected
0x08: Power Supply input lost (AC/DC)
0xEC(236) PSU3 Slow FAN1 0x04 FAN Discrete(0x07)
0x01: Transition to OK
0x10: Transition to Non-Critical from more severe
0x40: Transition to Non-Recoverable
0xED(237) PSU3 PWR Detect 0x08 Power Supply Discrete(0x6F)
0x01: Presence Detected
0x02: Power Supply Failure Detected
0x58(88) PSU3 Power Out 0x08 Power Supply Threshold(0x01)
Upper Non-Critical - going high
Upper Critical - going high
0x59(89) PSU3 Over Curr 0x03 Current Discrete(0x07)
0x01: Transition to OK
0x10: Transition to Non-Critical from more severe
0x40: Transition to Non-Recoverable
0xEE(238) PSU4 Power In 0x08 Power Supply Threshold(0x01)
Upper Non-Critical - going high
Upper Critical - going high
Lower Non-critical - going low
Lower Critical - going low
0xEF(239) PSU4 Over Temp 0x01 Temperature Discrete(0x07)
0x01: Transition to OK
0x10: Transition to Non-Critical from more severe
0x40: Transition to Non-Recoverable
0xF0(240) PSU4 AC Lost 0x08 Power Supply Discrete(0x6F)
0x01: Presence Detected
0x08: Power Supply input lost (AC/DC)
0xF1(241) PSU4 Slow FAN1 0x04 FAN Discrete(0x07)
0x01: Transition to OK
0x10: Transition to Non-Critical from more severe
0x40: Transition to Non-Recoverable
0xF2(242) PSU4 PWR Detect 0x08 Power Supply Discrete(0x6F)
0x01: Presence Detected
0x02: Power Supply Failure Detected
0x63(99) PSU4 Power Out 0x08 Power Supply Threshold(0x01)
Upper Non-Critical - going high
Upper Critical - going high
0x64(100) PSU4 Over Curr 0x03 Current Discrete(0x07)
0x01: Transition to OK
0x10: Transition to Non-Critical from more severe
0x40: Transition to Non-Recoverable