6.2.8 Enabling WriteCache
You may manually enable the RAID controller’s WriteCache option after creating a RAID set
to improve the data transmission performance.
When you enable WriteCache, you may lose data when a power interruption occurs while
transmitting or exchanging data among the drives.
The WriteCache function is recommended for RAID 1 and RAID 10 sets.
To enable WriteCachea
1. From the
Management Menu, select Objects > Adapter, select an existing adapter,
and then press <Enter> to display the adapter properties.
2. Select
Disk WC, and then press <Enter> to turn on the option.
3. From the Management Menu, select Objects > Virtual Drive, select an existing
adapter and press <Enter>. Select View/Update Parameters and press <Enter> to
display the adapter properties.
Management
Congure
Initialize
Objects
Rebuild
Check Consistency
Disk Write Cache - Off(Write Through) or On(Write Back)
Objects
Adapter
Virtual Drive
Physical Drive
Adapter 0
Rebuild Rate = 30
Chk Const Rate = 30
FGI Rate = 30
BGI Rate = 30
Disk WC = Off
Read Ahead = On
Bios State = Enable
Cont On Error = Yes
Fast Init = Enable
Auto Rebuild = On
Auto Resume = Enable
Disk Coercion = 1GB
Factory Default
LSI Software RAID Conguration Utility Ver C.05 Feb 17, 2012
BIOS Version A.10.09231523R
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option