Instruction Manual

ASUS P5BV-C Series 5-15
5.3.8 Rebuilding the RAID
This option is only for the RAID 1, RAID 5 and RAID 10 sets.
Rebuilding the RAID with other non-RAID disk
If any of the SATA hard disk drives included in the RAID array failed, the system
displays the status of the RAID volume as “Degraded” during POST. You can rebuild
the RAID array with other installed non-RAID disks.
To rebuild the RAID with other non-RAID disk:
1. At the prompt, press <Ctrl> + <I> to enter the Intel Matrix Storage Manager
RAID conguration.
2. If there is a non-RAID SATA Hard Disk available, the utility will prompt to rebuild
the RAID. Press <Enter>, then use up/down arrow keys to select the destination
disk or press <ESC> to exit.
Select a destination disk with the same size as the original hard disk.
3. The utilty immediately starts rebuilding after the disk is selected. The status of
the degraded RAID volume is changed to “Rebuild”.
DEGRADED VOLUME DETECTED
“Degraded“ volume and disk available for rebuilding detected.
Selecting a disk initiates a rebuild. Rebuild completes in the
operating system.
Select the port of destination disk for rebuilding (ESC to exit):
Port Drive Model Serial# Size
3HDS722580VLSA80 VN6Bxxxx 76.7GB
[ ]- Previous/Next [Enter]- Selects [ESC]- Exit