ESC8000A-E11 4U 機架式伺服器 使用手冊
T22730 4.00 版 2023 年 11 月發行 版權說明 ©ASUSTeK Computer Inc. All rights reserved.
目錄 使用注意事項.................................................................................................................................... vi 用電安全............................................................................................................................................vii 電磁安全................................................................................................................................vii 靜電元件...............................................................................
目錄 2.6.3 安裝 HBA/RAID 卡..............................................................................................2-20 2.6.4 安裝擴充卡至後端左側 PCIe 轉接卡上(選配).................................2-21 2.6.5 安裝擴充卡至後端右側 PCIe 轉接卡上(選配).................................2-23 2.6.6 安裝 OCP 3.0 卡至後端右側 OCP 3.0 插槽面板(選配)................2-25 2.6.7 (選配)安裝 PFR 模組..................................................................................2-26 2.7 連接排線................................................................................
目錄 3.5.10 區域網路堆疊設定(Network Stack Configuration)........................3-52 3.5.11 CSM 設定.............................................................................................................3-53 3.5.12 NVMe 設定(NVMe Configuration)........................................................3-54 3.5.13 SATA 設定..........................................................................................................3-55 3.5.14 AMD 記憶體設定狀態.......................................................................
使用注意事項 操作伺服器之前請務必詳閱以下注意事項,避免因人為的疏失造成系統損傷甚至人 體本身的安全。 請勿使用非本產品配備的電源線,由於電路設計之不同,將有可能造成 內部零件的損壞。 ‧ 使用前,請檢查每一條連接線是否都已經依照使用手冊指示連接妥當,以及電源 線是否有任何破損,或是連接不正確的情形發生。如有任何破損情形,請儘速與 您的授權經銷商聯絡,更換良好的線路。 ‧ 伺服器安放的位置請遠離灰塵過多,溫度過高,太陽直射的地方。 ‧ 保持機器在乾燥的環境下使用,雨水、溼氣、液體等含有礦物質將會腐蝕電子線 路。 ‧ 使用伺服器時,務必保持周遭散熱空間,以利散熱。 ‧ 使用前,請檢查各項周邊設備是否都已經連接妥當再開機。 ‧ 避免邊吃東西邊使用伺服器,以免污染機件造成故障。 ‧ 請避免讓紙張碎片、螺絲及線頭等小東西靠近伺服器之連接器、插槽、孔位等 處,避免短路及接觸不良等情況發生。 ‧ 請勿將任何物品塞入伺服器機件內,以避免引起機件短路,或是電路損毀。 ‧ 伺服器開機一段時間之後,散熱片及部份IC表面可能會發熱、發燙,請勿用手觸 摸,並請檢查系統是否散熱不良。 ‧ 在安裝或是移除周邊產品時請先關閉電源。 ‧ 在
用電安全 電磁安全 ‧ 拆裝任何元件或是搬移伺服器之前,請先確定與其連接的所有電源都已經拔掉。 ‧ 拆裝任何元件上連接的訊號線之前,請先拔掉連接的電源線,或是先安裝訊號線 之後再安裝電源線。 ‧ 使用一隻手拆裝訊號線,以避免接觸到兩個不同電位表面造成不當的電流突波衝 擊產生。 ‧ 伺服器電源線請勿與其他事物機器共用同一個插座,儘量不要使用延長線,最好 能夠連接一台不斷電系統 UPS。 靜電元件 處理器、記憶體、主機板、介面卡、磁碟機、硬碟機等設備,是由許多精密的積體 電路與其它元件所構成,這些積體電路很容易因為遭受靜電的影響而損壞。因此,在 拆裝任何元件之前,請先做好以下的準備: ‧ 如果您有靜電環等防靜電設備,請先戴上。 ‧ 假如您所處的環境並沒有防靜電地板,開始拆裝伺服器之前,請您先將身體可能 帶的靜電消除。 ‧ 在尚未準備安裝前,請勿將元件由防靜電袋中取出。 ‧ 將元件由防靜電袋中取出時,請先將它與伺服器金屬平面部份碰觸,釋放靜電。 ‧ 拿持元件時儘可能不觸碰電路板,及有金屬接線的部份。 ‧ 請勿用手指接觸伺服器之連接器、IC 腳位、附加卡之金手指等地方。 ‧ 欲暫時置放元件時請放置在防靜電墊或是防靜
關於本使用手冊 本使用手冊主要是針對有經驗且具有個人電腦硬體組裝知識的使用者所撰寫的。本 手冊可以幫助您建立起最新、功能強大的 ESC8000A-E11、ESC8000A-E11S 華碩伺 服器。手冊內容介紹本產品各部份元件的拆裝、設定,因此,部份元件可能是選購配 備,並未包含在您的產品當中,假如您有需要選購該配備,請向本公司授權經銷商洽 詢。 章節說明 本使用手冊的內容結構如下: 第一章:系統導覽 本章以清楚的圖示帶您認識華碩伺服器的功能及特色,包括系統的前、後面板以及 內部功能的介紹。 第二章:硬體安裝 本章以逐步說明的方式,教您如何將系統所需的零組件正確地安裝至本伺服器裡 頭。 第三章:BIOS 程式設定 本章提供伺服器之 BIOS 的升級與管理及 BIOS 設定的相關訊息。 第四章:安裝驅動程式 本章提供主機板相關之驅動程式的安裝說明。 附錄 在本附錄裡將列出相關的聯絡資訊。 viii
提示符號 以下為本手冊所使用到的各式符號說明: 警告:提醒您在進行某一項工作時要注意您本身的安全。 小心:提醒您在進行某一項工作時要注意勿傷害到主機板元件。不當的 動作可能會對產品造成損害。 注意:重點提示,重要的注意事項。您必須遵照使用手冊所描述之方式 完成一項或多項軟硬體的安裝或設定。 說明:小祕訣,名詞解釋,或是進一步的資訊說明。提供有助於完成某 項工作的訣竅和其他額外的資訊。 哪裡可以找到更多的產品資訊 您可以經由下面所提供的兩個管道來獲得您所使用的華碩產品資訊以及軟硬體的升 級資訊等。 1. 華碩網站 您可以到 https://www.asus.com/tw/ 華碩電腦全球資訊網,來取得所有關於華碩軟硬 體產品的各項資訊。 2. ASUS Control Center(ACC)使用手冊 本使用手冊介紹如何設定並使用華碩伺服器管理工具,請至 asuscontrolcenter.asus.
產品之限用物質含有情況 「產品之限用物質含有情況」之相關資訊,請參考下表。 單元 鉛 (Pb) 汞 (Hg) 限用物質及其化學符號 六價鉻 鎘 (Cd) (Cr+6) 印刷電路板及其 - o o o 電子組件 外殼 o o o o 散熱設備 - o o o 電源供應器 - o o o 其他及其配件 - o o o 備考 1 "o" 係指該項限用物質之百分比含量未超出百分比含量基準值。 多溴聯苯 (PBB) 多溴二苯醚 (PBDE) o o o o o o o o o o 備考 2 "-" 係指該項限用物質為排除項目。 產品回收與處理 華碩與資源回收業者以最高標準相互配合,以保護我們的環境,確保工作者的安 全,以及遵從全球有關環境保護的法律規定。我們保證以資源回收的方式回收以往生 產的舊設備,透過多樣的方式保護環境。 如欲了解更多關於華碩產品資源回收資訊與聯絡方式,請連線上網至 CSR(Corporate Social Responsibility)網頁:http://csr.asus.com/english/Takeback.
第一章: 系統導覽 本章以清楚的圖示帶您認識華碩伺服器的功能及特色, 包括系統的前、後面板以及內部功能的介紹。 1
1.
1.
1.3 產品規格表 華碩 ESC8000A-E11 是一款精心打造的 4U 伺服器,內裝 KMPG-D32 系列伺服器 主機板,支援 AMD EPYC™ 7003 處理器,並包含最新的相關技術。 機種型號 ESC8000A-E11 中央處理器 / 系統匯流排 2 x 插槽 SP3(LGA 4094) AMD EPYC™ 7002 / 7003 系列 核心邏輯 系統單晶片(SoC) 總插槽數 32(每個 CPU 8 通道;每個 CPU 16 個記憶體模組) 擴充容量 最高可擴充達 4096GB 記憶體類型 * 請參考華碩官方網站 https://www.asus.com/tw/ 以查詢最新記 憶體 AVL 更新資訊 DDR4 3200 / 2933 RDIMM/LRDIMM/3DS LRDIMM 記憶體 記憶體大小 64GB、32GB、16GB(RDIMM) 64GB、128GB(LRDIMM) 64GB、128GB、256GB(LRDIMM 3DS / 3DS RDIMM) * 請參考華碩官方網站 https://www.asus.
機種型號 ESC8000A-E11 儲存裝置插槽 I = 內建 A 或 S 為可熱插拔 8 x 可熱抽換 3.5 吋儲存裝置插槽 - 背板支援 4 x SATA/SAS + 4 x SATA/SAS/NVMe 儲存裝置* -儲 存裝置插槽位置請參考 2.5 安裝儲存裝置 * SATA/SAS 儲存裝置需搭配選購的 HBA / RAID 卡 網路功能 網路 1 x 管理用網路埠 選配 OCP 適配器: 最高至 200GbE 或 HDR 無限頻寬適配器 顯示功能 顯示晶片 整合式 BMC(Aspeed AST2600) 前面板 I/O 連接埠 2 x USB 3.2 Gen 1 連接埠 1 x 顯示器連接埠 1 x 序列埠 後面板 I/O 連接埠 1 x RJ-45 管理網路埠 開關 / LED 指示燈 前面板: 1 x Q-Code/Port 80 指示燈 1 x 電源開關 / 指示燈 1 x Location 開關 / 指示燈 1 x 訊息指示燈 後面板: 1 x Location 指示燈 支援作業系統 請參考華碩官方網站 https://www.asus.
1.4 前端面板 本伺服器的前端面板提供了簡單的存取功能,包括電源按鈕、相關的 LED 指示燈 以及 USB 埠,可方便您隨時瞭解系統的狀況。 金屬握把 3.5 吋儲存裝置插槽 1-8 RESET 半長 / 全高擴充卡插槽 金屬握把 Q Code Q Code VGA 埠 USB 3.2 Gen 1 連接埠 Q-Code 指示燈 電源按鈕含指示燈 重置按鈕 Location 按鈕含指示燈 訊息指示燈 序列埠 Asset tag(財產標籤) 1.
1.6 基本單位 SKU 選項 ESC8000A-E11 伺服器配備擴充卡插槽,可設定 4 種基本單位 SKU 以符合各式各 樣的擴充需求,可額外支援 8 張雙槽 GPU 擴充卡。 1.6.1 支援 2 PCIe + 2NVMe PCIe x16(Gen4 x8 link)FHHL 插槽 RESET NVMe 插槽 PCIe x16(Gen4 x16 link)FHHL 插槽 Q Code Q Code 1.6.2 支援 1 PCIe + 1 OCP3.0 + 2NVMe PCIe x16(Gen4 x8 link)FHHL 插槽 RESET OCP3.0(Gen4 x16 link)NIC 插槽 NVMe 插槽 Q Code Q Code 1.6.3 支援 3 PCIe PCIe x16(Gen4 x8 link)FHHL 插槽 RESET PCIe x8(Gen4 x8 link)LPHL 插槽 OCP3.
1.6.
1.7 內部組件 下圖即為本伺服器的標準內部組件: 1. 備援式電源供應器 2. 華碩 KMPG-D32 伺服器主機板 3. 系統風扇 4. 8 x 可抽換之 3.5 吋儲存裝置插 槽 5. GPU SKU 面板含 8 個全高 / 全 長 PCIe 擴充卡插槽 6. Asset Tag(財產標籤,隱藏) 7. PCIe 擴充卡插槽的轉接卡支撐 架(Gen4 x8 link) 8.
1.8 LED 顯示燈號說明 1.8.
1.8.
1.8.
第二章: 硬體安裝 本章以逐步說明的方式,教您如何將系統所需的零組件 正確地安裝至本伺服器裡頭。 2
2.1 機殼上蓋 本章節圖示僅供參考。系統設計可能會依型號而異,但安裝步驟均相 同。 請依照以下步驟,打開後側機殼上蓋: 2-2 1. 使用螺絲起子鬆開機殼兩側的 2 顆螺絲。 2. 按下機殼上的按鈕。 3.
請依照以下步驟,打開前端機殼上蓋: 1. 使用螺絲起子鬆開機殼兩側的 2 顆螺絲。 2. 鬆開 2 顆固定機箱上蓋的指旋螺絲。 3.
2.2 導風罩 本章節圖示僅供參考。系統設計可能會依型號而異,但安裝步驟均相 同。 請依照以下步驟,移除導風罩: 2-4 1. 鬆開固定導風罩通風口處的指旋螺絲。 2.
請依照以下步驟,重新安裝導風罩: 1. 找到先前移除導風罩的位置,將通風口處的螺絲孔位對準。 2.
2.
安裝中央處理器 請依照以下步驟安裝處理器: 1. 依照 2.1 機殼上蓋 的說明移除前端上蓋板。 2. 依照 2.2 導風罩 的說明移除導風罩。 3. 鬆開固定安裝盒上蓋的螺絲。 4. 輕輕向上掀起邊框。 安裝盒上蓋 邊框 外蓋 5.
6. 將裝有 C P U 的托架安裝至邊框 內,並移除保護蓋。 裝有 CPU 的托架只能以 單一方向正確地安裝到邊 框。切記請勿用力地將裝 有 CPU 的托架以錯誤的 方向進行安裝。 7. 裝有 CPU 的托架 外蓋 保護蓋 對齊 CPU 插槽蓋上邊框。 裝有 CPU 的托架 8. 將安裝盒上蓋的三個螺絲使用螺絲起子 分別鎖上。 安裝盒上蓋螺絲規格為 T20, 扭矩值建議為 16.1±1.2 kgf-cm (14.0±1.
9. 將散熱器上的四個螺絲,使用十字螺絲 起子分別鎖上,使散熱器固定於主機板 上。將四個螺絲使用螺絲起子依對角的 鎖定方式分別鎖上,使散熱器穩固於主 機板上。 安裝盒上蓋螺絲規格為 T20, 扭矩值建議為 16.1±1.2 kgf-cm (14.0±1.0 lbf-in)。 10. 依照 2.
2.4 系統記憶體 2.4.
2.4.
2.4.3 安裝記憶體模組 安裝記憶體模組前,請確認已安裝中央處理器、散熱器與導風罩。 請依照下面步驟安裝記憶體模組: 1. 先將記憶體模組插槽的固定卡榫扳 開。 2. 將記憶體模組的金手指對齊記憶體模 組插槽的溝槽,並且在方向上要注意 金手指的缺口要對準插槽的凸起點。 記憶體模組缺口 插槽凸起點 往外扳開記憶體模 組插槽的卡榫 記憶體插槽上的凹槽為設計僅一個方向供記憶體模組插入,請在裝入 前,確定記憶體模組與記憶體插槽上的安裝方向是契合的。 3. 最後緩緩將記憶體模組插入插槽中, 若無錯誤,插槽的卡榫會因記憶體模 組置入而自動扣到記憶體模組的凹孔 中。 卡榫會在記憶體模組 正確置入後自動扣上 請將記憶體模組缺口對準插槽的凸起點並垂直插入,以免造成記憶體模 組缺口損壞。 2.4.4 取出記憶體模組 請依照以下步驟取出記憶體模組: 1. 依照 2.1 機殼上蓋 的說明移除後端上 蓋板。 2. 壓下記憶體模組插槽的固定卡榫以鬆開 記憶體模組。 3.
2.5 安裝儲存裝置 ESC8000A-E11 伺服器支援 8 個 3.5 吋 SATA/SAS 或 8 個 NVMe 熱抽換儲存裝置 裝置。儲存裝置安裝的方式,為裝入模組式儲存裝置擴充槽後經由 SATA/SAS/NVME 背板連接主機板或 HBA/RAID 卡。 插槽 7 插槽 5 插槽 3 插槽 1 插槽 8 插槽 6 插槽 4 插槽 2 • 插槽 1 至 4 支援 NVMe/SATA/SAS。SATA/SAS 支援需使用選配 HBA/RAID 卡(支援 tri-mode 卡)。 • 所有插槽均支援 3.5 / 2.5 吋儲存裝置。 2.5.1 安裝 3.5 吋儲存裝置 請按照以下的步驟來安裝 3.5 吋儲存裝置: 1. 朝右方撥開固定扣。 2.
3. 將儲存裝置擴充槽放置在平坦的桌面 上,置入 3.5 吋儲存裝置。 4. 當儲存裝置安裝完畢後,請以手緊握 住儲存裝置槽握把置入系統的插槽 中,將其輕推至機殼底部。請將握把 輕輕地推回原位並輕扣固定,使儲存 裝置槽能夠緊密地固定在機殼中。 5. 若要安裝其他 3.
2.5.2 安裝 2.5 吋儲存裝置 請按照以下的步驟來安裝 2.5 吋儲存裝置: 1. 依照 2.5.1 安裝 3.5 吋儲存裝置 的步驟 1-2 由機殼中取出儲存裝置擴充槽。 2. 取出準備安裝的儲存裝置與螺絲配件。 3. 置入儲存裝置,再使用 4 顆螺絲將儲 存裝置鎖緊固定在儲存裝置槽內。 4. 依照 2.5.1 安裝 3.5 吋儲存裝置 的步驟 4 由裝回儲存裝置擴充槽。 ‧ 置入儲存裝置模組後,儲存裝置擴充槽上的 SATA/SAS/NVME 接頭會 完全與 SATA/SAS/NVME 背板上的接孔契合。 ‧ 如果儲存裝置槽有正確地安裝,您將會看到儲存裝置槽外緣與機殼呈 現切齊的狀態。 5. 若要安裝其他 2.
2.6 擴充插槽 在安裝或移除擴充卡之前,請先拔除電源線。如不這麼做可能會導致人 身傷害與損壞主機板上的元件。 2.6.1 安裝擴充卡至前端 PCIe 轉接卡上(選配) 本伺服器內建的 PCI Express 插槽已經預先安裝一個特殊設計的轉接卡,上面提供 一個 x16 插槽(Gen4 x8 link),可以安裝一張全高、半長的 PCIe 擴充卡。 請依照以下步驟安裝 PCIe 擴充卡至前端 PCIe 轉接卡上: 1. 從機殼上面移除固定轉接卡的螺絲。 2.
3. 將轉接卡放置於平坦的桌面。 4. 以逆時針方向撥開金屬托架鎖(A),取下金屬托架鎖後再將金屬擋板從轉接卡 上面移除(B)。 5. 將擴充卡插入轉接卡上的 PCIe 插槽,請確認卡上的金手指部分已經完全沒入插 槽中(A),將回金屬托架鎖並以順時針方向鎖緊(B)。 在安裝擴充卡之前,請先閱讀使用說明文件,以確認是否需要在安裝前 先做必要的硬體設定。 6.
2.6.2 安裝華碩 PIKE II 卡 請依照以下步驟安裝華碩 PIKE II 卡: 1. 取出準備安裝的華碩 PIKE II 卡。 2. 依照 2.6.1 安裝擴充卡至前端 PCIe 轉接卡上(選配) 的說明安裝華碩 PIKE II 卡 至轉接卡。 3. 連接華碩 PIKE II 卡上的 mini-SAS HD 排線(A)至 NVMe/SATA/SAS 背板 (B)。請參考 2.7.1 NVMe/SATA/SAS 背板 的說明。 4.
5. 將暫存電源模組墊片上的螺絲孔對齊暫存電源模組支架上的螺絲孔,鎖上隨附的 螺絲固定。 6. 將鎖上墊片的暫存電源模組支架安裝至機殼,並鎖上步驟 4 移除的螺絲固定 (A),接著將暫存電源模組對齊並裝入暫存電源模組支架(B)。 7.
2.6.3 安裝 HBA/RAID 卡 請依照以下步驟安裝 HBA/RAID 卡: 1. 取出準備安裝的 HBA/RAID 卡。 2. 依照 2.6.1 安裝擴充卡至前端 PCIe 轉接卡上(選配) 的說明安裝 HBA/RAID 卡 至轉接卡。 3. 連接華碩 HBA/RAID 卡上的 Slimline SAS 排線(A)至 NVMe/SATA/SAS 背板 (B)。請參考 2.7.1 NVMe/SATA/SAS 背板 的說明。 ‧ 圖示僅供參考。 ‧ 詳細說明請參考華碩官方網站 https://www.asus.
2.6.4 安裝擴充卡至後端左側 PCIe 轉接卡上(選配) 請依照以下步驟安裝 PCIe 擴充卡至後端左側 PCIe 轉接卡上: 1. 鬆開將轉接卡固定於機殼上的指旋螺絲(A),將轉接卡朝外拉出,使之鬆開脫 離機殼,再將轉接卡取出(B)。 2.
3. 將擴充卡安裝至左側 PCIe 轉接卡上的 PCIe x8 插槽。 4. 鎖上金屬托架鎖以固定擴充卡。 5.
2.6.5 安裝擴充卡至後端右側 PCIe 轉接卡上(選配) 請依照以下步驟安裝 PCIe 擴充卡至後端右側 PCIe 轉接卡上: 1. 鬆開將轉接卡固定於機殼上的 2 顆指旋螺絲(A),將轉接卡朝外拉出,使之鬆 開脫離機殼,再將轉接卡取出(B)。 2.
3. 將擴充卡安裝至右側轉接卡上的 PCIe 插槽(A),鎖上金屬托架鎖以固定擴充卡 (B)。 4.
2.6.6 安裝 OCP 3.0 卡至後端右側 OCP 3.0 插槽面板(選配) 請依照以下步驟安裝 OCP 3.0 卡至後端右側 OCP 3.0 插槽面板: 1. 將 OCP 3.
2.6.7 (選配)安裝 PFR 模組 選配的 PFR 模組將會預先安裝於主機板上並連接 PFR 模組插槽。 ‧ 圖示僅供參考。 ‧ 詳細說明請參考華碩官方網站 https://www.asus.com/tw/。 1. 找到主機板上 PFR 模組插槽。 2.
3.
2.7 連接排線 系統內的排線在出廠前都已經預先連接妥當。您不需再另外安裝,除非 您需要更換或安裝增加的硬體,才需要重新連接/移除。 2.7.
2.7.
2.8 移除/選配系統組件 當您在安裝或移除系統裝置或是替換損壞的零組件時,或許需要移除先前所安裝的 系統組件。而本章節的內容就是要告訴大家如何移除與重新安裝下列各項系統組件。 1. GPU 風扇 2. 備援式電源供應器模組 請在移除各項系統組件前,先確認已關閉系統電源。 • 您可能需要在安裝組件前,先移除先前安裝的組件或出廠組件。 • 備援式電源供應器模組支援熱抽換功能。 2.8.1 GPU 風扇 請依照以下的步驟,移除 GPU 風扇: 1. 按住風扇缺口(A),鬆開卡榫 (B)。 2. 用手指握住風扇左右兩側,將風扇向 上取出,並放至於一旁。 3. 重覆步驟 1-2,即可移除其他系統風 扇 依照以下的步驟,安裝 GPU 風扇: 1.
2.8.2 更換電源供應器 請依照以下的步驟,更換損壞的電源供應器。 • 如要啟用熱抽換功能(備援模式),請確認已連接至少 2 個功能正 常的電源供應器模組。 • 建議您使用雙手進行以下的步驟。 • 請使用相同瓦數與規格的電源供應器模組。若使用不同瓦數的電源供 應器模組作為組合則可能會發生不穩定的情況與造成系統的損壞。 • 為了穩定的執行環境,在開啟伺服器電源前請確認已連接至少 2 個 功能正常的電源供應器模組。 • 為了保有穩定的電源輸出,請使用本伺服器產品包裝內提供的電源線 來連接伺服器。 1. 請拔除電源線後,將電源供應器上的握把往上扳。 2.
3. 取出要更換的電源供應器模組。 4.
2.9 安裝 GPU 卡 ‧ 請使用雙手進行以下的步驟。 ‧ 在安裝前請先閱讀顯示卡所附的說明書。 ‧ 當安裝超過一個以上的顯示卡時,建議依以下順序進行安裝:PCIE1 > PCIE4 > PCIE2 > PCIE3 > PCIE5 > PCIE8 > PCIE6 > PCIE7。請參考 2.7.2 PCIe SKU 面板 的說明。 請依照以下步驟,將顯示卡安裝至系統中: 1.
2. (選配)使用 Nvidia CPU-12V 或更高瓦數的圖形顯示卡。請準備好顯示卡轉接 線或電源線。 或 Nvidia CPU-12V 顯示卡轉接線 需要先連接 Nvidia 所附的轉接線至顯示卡,再透過 Nvidia 轉接線連接華碩系統所附的顯示卡電源線。若未 使用 Nvidia 轉接線,則 Nvidia CPU-12V GPU 卡可能會 無法運作,甚至損壞系統。 華碩 CPU 8-pin 電源線 華碩 CPU 8-pin 電源線需連接至顯示卡及 6-pin 電源線。 這條 N v i d i a 轉接線會隨附在 Nvidia CPU-12V 顯示卡的配件 裡。如有遺失,請向您的供應商 或經銷商諮詢。 3.
Nvidia® CPU-12V 或更高瓦數顯示卡之電源線與 Nvidia® CPU-12V 顯示卡 轉接線 電源線 Nvidia CPU-12V 顯示卡轉接線 Nvidia® CPU-12V 或更高瓦數顯示卡之華碩 CPU 8-pin 電源線 華碩 CPU 8-pin 電源線 4.
5. 在導風罩內部鎖上 2 顆螺絲,將導風罩固定到顯示卡上面。 供穿過纜線的凹口 6.
7. 將電源線另一端(6-pin 電源接頭)連接至伺服器中間的 6-pin 電源插座,,鎖上 步驟 1 移除的 2 顆螺絲以完成固定。 8. 若要安裝其他 GPU 卡時,請參考前面的步驟 1-7 進行。 9.
2.
第三章: BIOS 程式設定 本章提供伺服器之 BIOS 的升級與管理及 BIOS 設定的 相關訊息。 3
3.1 管理、更新您的 BIOS 程式 下列軟體讓您可以管理與更新主機板上的 BIOS 設定。 1. ASUS CrashFree BIOS 3 當 BIOS 程式毀損時,使用可開機的 USB 隨身碟來更新 BIOS 程式。 2. ASUS EzFlash 3. BUPDATER 使用 USB 隨身碟更新 BIOS。 使用可開機的 USB 隨身碟在 DOS 環境下更新 BIOS 程式。 上述軟體請參考相關章節的詳細使用說明。 建議您先將主機板原始的 BIOS 程式備份到可開機的 USB 隨身碟中, 以備您往後需要再度安裝原始的 BIOS 程式。使用華碩線上更新(ASUS Update)程式來拷貝主機板原始的 BIOS 程式。 3.1.
3.1.2 使用華碩 EzFlash 更新程式 華碩 EzFlash 程式讓您能輕鬆的更新 BIOS 程式,可以不必再透過開機片的冗長程 序或是到 DOS 模式下執行。 請至華碩網站 https://www.asus.com/tw/ 下載最新的 BIOS 程式檔案。 請依照下列步驟,使用 EzFlash 來更新 BIOS: 1. 將已存好最新版 BIOS 檔案的 USB 隨身碟插入 USB 連接埠。 2. 進入 BIOS 設定程式。來到 Tools 選單,選擇 Start ASUS EzFlash 後並按下 鍵將其開啟。 ASUSTek.
3.1.3 BUPDATER 工具程式 以下的 BIOS 畫面僅供參考,請依您所見的實際 BIOS 畫面為準。 BUPDATER 工具程式可以提供您在 DOS 環境下,使用儲存有更新的 BIOS 檔案的 USB 隨身碟來更新 BIOS 檔案。 更新 BIOS 檔案 請依照以下的步驟,使用BUPDATER 工具程式來更新 BIOS 檔案: 1. 請先造訪華碩網站(https://www.asus.com/tw/)下載最新主機板的 BIOS 檔案。並 將檔案儲存至可開機的 USB 隨身碟內。 2. 然後將華碩支援網站(support.asus.com)上的 BUPDATER 工具程式(BUPDATER. exe),下載並儲存至同一個可開機的 USB 隨身碟內。 3. 將系統開機至 DOS 環境下,然後使用鍵盤輸入指令: BUPDATER /i [filename].CAP [ filename] 這裡的意思就是輸入存放在 USB 隨身碟裡頭的最新或原本 BIOS 檔案名 稱,然後按 鍵。 A:\>BUPDATER /i[file name].
4. 程式會進行檢查檔案,然後開始更新 BIOS 檔案。 ASUSTek. EzFlash Utility Current Platform Platform : KMPG-D32 Version : 0402 Build date: 10/20/2021 Start Programming Flash. New Platform Platform : KMPG-D32 Version : 0403 Build date: 11/09/2021 DO NOT SHUTDOWN THE SYSTEM!!! Write 75% 請勿在更新 BIOS 程式檔案時關閉或重新啟動系統,此舉將會導致系統損 毀! 5. 完成更新後,程式會回到 DOS 畫面,請重新啟動系統,透過硬碟開機。 The BIOS update is finished! Please restart your system. C:\> 華碩 ESC8000A-E11 使用手冊 3-5
3.2 BIOS 程式設定 主機板擁有一片可編輯的韌體晶片,您可以依照 3.
3.2.1 BIOS 程式選單介紹 選單項目 功能表列 設定值 一般說明 操作功能鍵 3.2.
3.2.3 選單項目 於功能表列選定選項時,被選擇的功能將會反白,假設您選擇 Main 功能,則會顯 示 Main 選單的項目。 點選選單中的其他項目(如:Event Logs、Advanced、Monitor、Boot、Tool 與 Exit 等)也會出現該項目不同的選項。 3.2.4 子選單 在選單畫面中,若功能選項的前面有一個小三角形標記,代表此為子選單,您可以 利用方向鍵來選擇,並且按下 鍵來進入子選單。 3.2.5 操作功能鍵說明 在選單畫面的右下方為操作功能鍵說明,請參照功能鍵說明來選擇及改變各項功 能。 3.2.6 一般說明 在選單畫面的右上方為目前所選擇的作用選項的功能說明,此說明會依選項的不同 而自動變更。 3.2.7 設定值 這些存在於選單中的設定值是提供給使用者選擇與設定之用。這些項目中,有的 功能選項僅為告知使用者目前運作狀態,並無法更改,那麼此類項目就會以淡灰色顯 示。而可更改的項目,當您使用方向鍵移動項目時,被選擇的項目以反白顯示,代表 這是可更改的項目。 3.2.
3.3 主選單(Main) 當您進入 BIOS 設定程式時,首先出現的第一個畫面即為主選單,內容如下圖。 3.3.1 System Language [English] 設定系統使用語言。 3.3.2 System Date [Day xx/xx/xxxx] 設定系統日期。 3.3.
3.
3.5 進階選單(Advanced menu) 在進階選單(Advanced menu)裡的項目,為提供您變更 CPU 與其他系統裝置的設 定。 請注意當變更進階選單(Advanced menu)裡的項目時,在欄位中輸入不 正確的數值將會導致系統運作不正常。 3.5.
3.5.2 PSP 韌體版本 本選單顯示 PSP 韌體版本。 3.5.
3.5.
以下項目僅當 Custom Core Pstates 項目選擇 [Accept] 時才會出現。 Custom Pstate0 [Auto] 設定值有:[Auto] [Custom] 以下項目僅當 Custom Pstate0 設定為 [Custom] 時才會出現。 Pstate0 Freq (MHz) [0] 本項目可以指定核心頻率(MHz)。 CCD/Core/Thread Enablement 本項目可以啟用 CCD/Core/Thread Enablement。 S3 不支援 cores/threads 已被移除或關閉的系統。 CCD Control [Auto] 設定使用的 CCD 數量。設定值有:[Auto] [2 CCDs] [3 CCDs] [4 CCDs] [6 CCDs] Core Control [Auto] 設定使用的核心數量。設定值有:[Auto] [ONE (1 + 0)] [TWO (2 + 0)] [THREE (3 + 0)] [FOUR (4 + 0)] [FIVE (5 + 0)] [SIX (6 + 0)] [SEVEN (7 + 0)] SMT Control [A
Core Watchdog Core Watchdog Timer Enable [Auto] 本項目可以啟用或關閉 CPU Watchdog Timer。設定值有:[Disable] [Enable] [Auto] 以下項目僅當 Core Watchdog Timer Enable 設定為 [Enabled] 時才會出 現。 Core Watchdog Timer Interval [Auto] 設定值有:[21.461s] [10.730s] [3.364s] [2.681s] [1.340s] [669.41m s] [334.05ms] [166.37ms] [82.53ms] [40.61ms] [20.970ms] [10.484ms] [3.241ms] [2.620ms] [1.309ms] [654.08us] [326.4us] [162.56us] [80.64us] [39.
以下項目僅當 SEV-ES ASID Space Limit Control 設定為 [Manual] 時才會 出現。 SEV-ES ASID Space Limit [1] 本項目可以設定 SEV-ES ASID 的空間限制。 Streaming Stores Control [Auto] 本項目可以啟用或關閉 Streaming Stores 功能。設定值有:[Disabled] [Enabled] [Auto] Local APIC Mode [Auto] 設定值有:[Compatibility] [XAPIC] [X2APIC] [Auto] ACPI _CST C1 Operation [Auto] 決定是否向作業系統宣布 C1 狀態。設定值有:[Disabled] [Enabled] [Auto] MCA error thresh enable [Auto] 本項目可以啟用或關閉 MCA 錯誤臨界值。設定值有:[False] [True] [Auto] 以下項目僅當 MCA error thresh enable 設定為 [True] 時才會出現。 MCA error thresh c
Amount of Memory to Cover [0] 本項目可以十六進位指定主機板的系統記憶體。 SMEE [Auto] 本項目可以啟用或關閉 SMEE。設定值有:[Disabled] [Enabled] [Auto] Action on BIST Failure [Auto] 本項目可以設定偵測到 CCD BIST 失敗時的動作。設定值有:[Do Nothing] [DownCCD] [Auto] Fast Short REP MOVSB [Auto] 預設值為 1,作業系統支援時可作為分析目的設為 0。設定值有:[D i s a b l e d] [Enabled] Enhanced REP MOVSB/STOSB [Auto] 預設值為 1,作業系統支援時可作為分析目的設為 0。設定值有:[D i s a b l e d] [Enabled] REP-MOV/STOS Streaming [Disabled] 設定值有:[Disabled] [Enabled] IBS hardware workaround [Auto] 設定值有:[Auto] [Enabled] DF Common
Memory Addressing NUMA nodes per socket [Auto] 本項目可指定每個插槽的 NUMA 節點數量。設定值有:[NPS1] [NPS2] [NPS4] [Auto] Memory interleaving [Auto] 本項目可設定記憶體交插存取。設定值有:[Disabled] [Auto] Memory interleaving size [Auto] 本項目可設定記憶體交插存取容量。設定值有:[256 Bytes] [512 Bytes] [1 KB] [2 KB] [Auto] 1TB remap [Auto] 本項目用以嘗試重新映射 1TB。設定值有:[Do not remap] [Attempt to remap] [Auto] DRAM map inversion [Auto] 本項目可以啟用或關閉 DRAM 映射反轉。設定值有:[Disabled] [Enabled] [Auto] Location of private memory regions [Auto] 本項目可以控制私有記憶體區域(PSP、SMU 與 CC6)是否在記憶體上端或是 被分
ACPI SLIT same socket distance [C] 本項目可以指定在相同插槽內與其他實體區域的距離。 ACPI SLIT remote socket distance [20] 本項目可以指定與遠端插槽的距離。 ACPI SLIT local SLink distance [32] 本項目可以指定在相同插槽內與 SLink 區域的距離。 ACPI SLIT remote SLink distance [3C] 本項目可以指定在其他插槽內與 SLink 區域的距離。 ACPI SLIT local inter-SLink distance [FF] 本項目可以指定在相同插槽內兩個 SLink 區域的距離。 ACPI SLIT remote inter-SLink distance [FF] 本項目可以指定在不同插槽內兩個 SLink 區域的距離。 Link GMI encryption control [Auto] 本項目可以用來設定 GMI 加密控制。設定值有:[Disabled] [Enabled] [Auto] xGMI encryption control [Auto]
xGMI TXEQ Mode [Auto] 本項目可以選擇 XGMI TXEQ/RX 模式。設定值有:[TXEQ_Disabled] [TXEQ_ Lane] [TXEQ_Link] [TXEQ_RX_Vet] [Auto] xGMI 18GACOFC [Auto] 本項目可以啟用或關閉 18GACOFC 控制。設定值有:[Auto] [Enable] [Disable] Disable DF to external IP SyncFloodPropagation [Auto] 本項目可以啟用或關閉禁止 DF 到外部 IP 同步 SYN 洪水攻擊。設定值有:[Sync Flood disabled] [Sync Flood enabled] [Auto] Disable DF sync flood propagation [Auto] 本項目可以啟用或關閉 DF 同步 SYN 洪水攻擊。設定值有:[Sync Flood disabled] [Sync Flood enabled] [Auto] Freeze DF module queues on error [Auto] 本項目可以啟用或關閉發生錯誤
以下項目僅當 Overclock 設定為 [Enabled] 時才會出現。 Memory Clock Speed [Auto] 指定記憶體時鐘頻率。設定值有:[Auto] [667MHz] [800MHz] [933MHz] [1067M H z] [1200M H z] [1333M H z] [1467M H z] [1600M H z] [1633M H z] [1667MHz] [1700MHz] [1733MHz] [1767MHz] [1800MHz] [400MHz] Tcl [Auto] 指定 CAS 延遲。設定值有:[Auto] [8 Clk] [9 Clk] [0Ah Clk] [0Bh Clk] [0Ch Clk] [0Dh Clk] [0Eh Clk] [0Fh Clk] [10h Clk] [11h Clk] [12h Clk] [13h Clk] [14h Clk] [15h Clk] [16h Clk] [17h Clk] [18h Clk] [19h Clk] [1Ah Clk] [1Bh Clk] [1Ch Clk] [1Dh Clk] [1Eh Clk] [1Fh Clk]
以下項目僅當 Trc Ctrl 設定為 [Manual] 時才會出現。 Trc [39] 指定 Active to Active/Refresh Delay Time。有效數值 87h-1Dh。 TrrdS [Auto] 指定 Activate to Activate Delay Time,不同分組架構(tRRD_S)。設定值 有:[Auto] [4 Clk] [5 Clk] [6 Clk] [7 Clk] [8 Clk] [9 Clk] [0Ah Clk] [0Bh Clk] [0Ch Clk] TrrdL [Auto] 指定 Activate to Activate Delay Time,相同分組架構(tRRD_L)。設定值 有:[Auto] [4 Clk] [5 Clk] [6 Clk] [7 Clk] [8 Clk] [9 Clk] [0Ah Clk] [0Bh Clk] [0Ch Clk] Tfaw Ctrl [Auto] 指定 Tfaw。設定值有:[Auto] [Manual] 以下項目僅當 Tfaw Ctrl 設定為 [Manual] 時才會出現。 Tfaw [1] 指定 Four Activa
TrdrdScL Ctrl [Auto] 指定 TrdrdScL。設定值有:[Auto] [Manual] 以下項目僅當 TrdrdScL Ctrl 設定為 [Manual] 時才會出現。 TrdrdScL [3] 指定 CAS to CAS Delay Time,相同分組架構。有效數值 Fh-1h。 TwrwrScL Ctrl [Auto] 指定 TwrwrScL。設定值有:[Auto] [Manual] 以下項目僅當 TwrwrScL Ctrl 設定為 [Manual] 時才會出現。 TwrwrScL [3] 指定 CAS to CAS Delay Time,相同分組架構。有效數值 3Fh-1h。 Trfc Ctrl [Auto] 指定 Trfc。設定值有:[Auto] [Manual] 以下項目僅當 Trfc Ctrl 設定為 [Manual] 時才會出現。 Trfc [138] 指定 Refresh Recovery Delay Time(tRFC1)。有效數值 3DEh-3Ch。 Trfc2 Ctrl [Auto] 指定 Trfc2。設定值有:[Auto] [Manual] 以下項目僅當 Trfc2
Trtp [Auto] 指定 Read CAS# to Precharge Delay Time。設定值有:[Auto] [5 Clk] [6 Clk] [7 Clk] [8 Clk] [9 Clk] [0Ah Clk] [0Bh Clk] [0Ch Clk] [0Dh Clk] [0Eh Clk] Tcke [Auto] 在記憶體時脈循環裡指定 CKE 最小值的高低脈寬調變。設定值有:[Auto] [1 Clk] [2 Clk] [3 Clk] [4 Clk] [5 Clk] [6 Clk] [7 Clk] [8 Clk] [9 Clk] [0Ah Clk] [0Bh Clk] [0Ch Clk] [0Dh Clk] [0Eh Clk] [0Fh Clk] [10h Clk] [11h Clk] [12h Clk] [13h Clk] [14h Clk] [15h Clk] [16h Clk] [17h Clk] [18h Clk] [19h Clk] [1Ah Clk] [1Bh Clk] [1Ch Clk] [1Dh Clk] [1Eh Clk] [1Fh Clk] Trdwr [Auto] 指定讀取至
TrdrdDd [Auto] 指定不同記憶體間讀取至讀取的周轉時間。設定值有:[Auto] [1 Clk] [2 Clk] [3 Clk] [4 Clk] [5 Clk] [6 Clk] [7 Clk] [8 Clk] [9 Clk] [0Ah Clk] [0Bh Clk] [0Ch Clk] [0Dh Clk] [0Eh Clk] [0Fh Clk] ProcODT [Auto] 指定 Processor ODT。設定值有:[Auto] [High Impedance] [480 ohm] [240 ohm] [160 ohm] [120 ohm] [96 ohm] [80 ohm] [68.6 ohm] [60 ohm] [53.3 ohm] [48 ohm] [43.6 ohm] [40 ohm] [36.9 ohm] [34.3 ohm] [32 ohm] [30 ohm] [28.
以下項目僅當 CAD Bus Timing User Controls 設定為 [Manual] 時才會出 現。 AddrCmdSetup [0] 本項目可以設定 CAD 匯流排訊號的運作時間。設定值有:[0] – [39] CsOdtSetup [0] 本項目可以設定 CAD 匯流排訊號的運作時間。設定值有:[0] – [39] CkeSetup [0] 本項目可以設定 CAD 匯流排訊號的運作時間。設定值有:[0] – [39] CAD Bus Drive Strength User Controls [Auto] 本項目可以設定 C A D 匯流排訊號為自動或手動。設定值有:[A u t o] [Manual] 以下項目僅當 CAD Bus Drive Strength User Controls 設定為 [Manual] 時 才會出現。 ClkDrvStren [Auto] 設定值有:[Auto] [120.0 Ohm] [60.0 Ohm] [40.0 Ohm] [30.0 Ohm] [24.0 Ohm] [20.
Common RAS Data Poisoning [Auto] 設定值有:[Enabled] [Disabled] [Auto] DRAM Post Package Repair [Disable] 本項目可以啟用或關閉 DRAM POST Package Repair。設定值有:[Enable] [Disable] RCD Parity [Auto] 設定值有:[Enabled] [Disabled] [Auto] DRAM Address Command Parity Retry [Auto] 設定值有:[Enabled] [Disabled] [Auto] Max Parity Error Replay [8] 十六進位的數值 1、2 或 3 為無效。設定值有:[0] – [39] Write CRC Enable [Auto] 設定值有:[Enabled] [Disabled] [Auto] DRAM Write CRC Enable and Retry Limit [Auto] 設定值有:[Enabled] [Disabled] [Auto] Max Write CRC Error Replay
Phy Configuration PMU Training DFE Read Training [Auto] 開啟 DFE 並執行 2D Read Training。設定值有:[Disabled] [Enabled] [Auto] FFE Write Training [Auto] 開啟 FFE 並執行 2D Read WriteTraining。設定值有:[Disabled] [Enabled] [Auto] PMU Pattern Bits Control [Auto] 設定值有:[Auto] [Manual] 以下項目僅當 PMU Pattern Bits Control 設定為 [Manual] 時才會出現。 PMU Pattern Bits [0] 設定值有:[0] - [9] DRAM Memory Mapping Chipselect Interleaving [Auto] 本項目可開啟或關閉經由記憶體晶片選擇交插存取存儲區。設定值有: [Disabled] [Auto] BankGroupSwap [Auto] 設定值有:[Enabled] [Disabled] [Auto] Bank
Memory MBIST MBIST Enable [Disabled] 本項目可以啟用或關閉 Memory MBIST。設定值有:[Enabled] [Disabled] 以下項目僅當 MBIST Enable 設定為 [Enabled] 時才會出現。 MBIST Test Mode [Auto] 本項目可以選擇 MBIST 測試模式,包括 Interface 模式或 Data Eye 模式。設定 值有:[Interface Mode] [Data Eye Mode] [Both] [Auto] MBIST Aggressors [Auto] 本項目可以啟用或關閉 M e m o r y A g g r e s s o r 測試。設定值有:[E n a b l e d] [Disabled] [Auto] MBIST Per Bit Slave Die Reporting [Auto] 設定值有:[Enabled] [Disabled] [Auto] Data Eye Pattern Select [PRBS] 設定值有:[PRBS] [SS0] [Both] Pattern Length [3]
以下項目僅當 Target Static Lane Control 設定為 [Enabled] 時才會出現。 Target Static Lane Select Upper 32 bits [0] 設定值有:[0] - [99999999] Target Static Lane Select Lower 32 bits [0] 設定值有:[0] - [99999999] Target Static Lane Select ECC [0] 設定值有:[0] - [9] Target Static Lane Value [0] 設定值有:[0] - [9] Worst Case Margin Granularity [Per Chip Select] 設定值有:[Per Chip Select] [Per Nibble] Read Voltage Sweep Step Size [1] 設定值有:[1] [2] [4] Read Timing Sweep Step Size [1] 設定值有:[1] [2] [4] Write Voltage Sweep Step Size [1] 設定值有:[1] [2] [4
以下項目僅當 Memory Healing BIST 設定為 [PMU Mem BIST]、[BIOS and PMU Mem BIST]、[PMU and Self-Healing Mem BIST] 或 [BIOS and PMU and Self-Healing Mem BIST] 時才會出現。 PMU Mem BIST Test Select [Algorithm #1, #2, #3] 本項目可以設定 PMU Mem BIST。 Algorithm #1: Simple Write-Read Static Refresh test; Algorithm #2: Write/ Read/Write data test; Algorithm #3: Agressor Row stress test 設定值有:[Algorithm #1] [Algorithm #2] [Algorithm #1, #2] [Algorithm #1, #3] [Algorithm #2, #3] [Algorithm #1, #2, #3] NBIO Common Options IOMMU [Auto] 本項目可以啟
Fan Control Fan Table Control [Auto] [Auto] 使用預設值。 [Manual] 可進行自訂。 以下項目僅當 Fan Table Control 設定為 [Manual] 時才會出現。 Low Temperature [0] 本項目可以 ℃ 為單位設定低溫。 Medium Temperature [0] 本項目可以 ℃ 為單位設定中間溫度。 High Temperature [0] 本項目可以 ℃ 為單位設定高溫。 Critical Temperature [0] 本項目可以 ℃ 為單位設定臨界溫度。 Low Pwm [0] 本項目可以在 0-100 間設定低 Pwm。 Medium Pwm [0] 本項目可以在 0-100 間設定中間 Pwm。 High Pwm [0] 本項目可以在 0-100 間設定高 Pwm。 Temperature Hysteresis [0] 本項目可以 ℃ 為單位設定溫度遲滯。 Pwm Frequency [25kHz] 設定值有:[100Hz] [25kHz] Fan Polarity [Negative] 設定值有:[Negative
以下項目僅當 Power Package Limit Control 設定為 [Manual] 時才會出 現。 Power Package Limit [280] 本項目可以自訂 PPT。 xGMI Link Width Control [Auto] [Auto] 使用預設 xGMI 鏈接寬度控制器設定。 [Manual] 可以自訂 xGMI 鏈接寬度控制器設定。 以下項目僅當 xGMI Link Width Control 設定為 [Manual] 時才會出現。 xGMI Force Link Width Control [Unforce] [Unforce] 不迫使 xGMI 至固定寬度。 [Force] 迫使 xGMI 至指定寬度。 以下項目僅當 xGMI Force Link Width Control 設定為 [Force] 時才會出 現。 xGMI Force Link Width [2] [0] 迫使 xGMI 鏈接寬度為 x2。 [1] 迫使 xGMI 鏈接寬度為 x8。 [2] 迫使 xGMI 鏈接寬度為 x16。 xGMI Max Link Width C
DLWM Support [Auto] 本項目可以啟用或關閉 DLWM 支援。設定值有:[Disabled] [Enabled] [Auto] Boost FmaxEn [Auto] [Auto] 使用預設 Fmax。 [Manual] 可設定開機 Fmax。 以下項目僅當 Boost FmaxEn 設定為 [Manual] 時才會出現。 BoostFmax [0] 本項目可以用來指定 開機 Fmax 頻率限制並套用至所有核心(MHz)。 EDC Current Tracking [Disable] 設定值有:[Disable] [Enable] 以下項目僅當 EDC Current Tracking 設定為 [Enable] 時才會出現。 EDC Tracking Current Threshold [0] 目前 AMP 的臨界值供 EDC Current Tracking 功能。 EDC Tracking Report Interval [1] 回報間隔。在 SMU 裡每 N 個觀察結果記錄為可修正 MCE。 LCLK Frequency Control Root Complex 0x
Root Complex 0x80 LCLK Frequency [Auto] 設定 Root Complex LCLK 頻率(匯流排範圍 0x80-0x9F)。 [Auto] 動態頻率控制(增強 PIO 設定將會生效)。 [593MHz] 設定 LCLK 頻率為 593MHz(覆蓋增強 PIO 設定)。 Root Complex 0xA0 LCLK Frequency [Auto] 設定 Root Complex LCLK 頻率(匯流排範圍 0xA0-0xBF)。 [Auto] 動態頻率控制(增強 PIO 設定將會生效)。 [593MHz] 設定 LCLK 頻率為 593MHz(覆蓋增強 PIO 設定)。 Root Complex 0xC0 LCLK Frequency [Auto] 設定 Root Complex LCLK 頻率(匯流排範圍 0xC0-0xDF)。 [Auto] 動態頻率控制(增強 PIO 設定將會生效)。 [593MHz] 設定 LCLK 頻率為 593MHz(覆蓋增強 PIO 設定)。 Root Complex 0xE0 LCLK Frequency [Auto]
NBIO RAS Common Options NBIO RAS Control [Auto] 設定值有:[Disabled] [MCA] [Legacy] [Auto] Egress Poison Severity High [30011] 每個位元設定為 1 表示關聯的出口埠為高嚴重度。1 個位元設定為 0 表示低嚴 重度。 Egress Poison Severity Low [4] 每個位元設定為 1 表示關聯的出口埠為高嚴重度。1 個位元設定為 0 表示低嚴 重度。 NBIO SyncFlood Generation [Auto] 此數值用以遮蔽 NBIO RAS 選項造成的 SYN 洪水。設定值有:[Disabled] [Enabled] [Auto] NBIO SyncFlood Reporting [Auto] 此數值用以啟用 SYN 洪水報告至 APML。設定值有:[Disabled] [Enabled] [Auto] Egress Poison Mask High [FFFCFFFF] 本項目用以遮蔽 EGRESS_POISON_STATUS 的錯誤記錄。每個位元設定為 1 時,
SLink Read Response OK [Disabled] 此數值可以指定 S L I N K 讀取回應錯誤是否轉換為 O k a y 回應。設定值有: [Disabled] [Enabled] SLink Read Response Error Handling [Log Errors in MCA] 此數值可以指定 SLINK 寫入回應錯誤是否轉換為 Okay 回應。當設定為 0 時, 寫入回應錯誤將被記錄於 MCA。當設定為 1,寫入回應錯誤將觸發 MCOMMIT 錯誤。當設定為 2,寫入回應錯誤將被轉換。設定值有:[E n a b l e d] [T r i g g e r MCOMMIT Error] [Log Errors in MCA] Log Poison Data from SLINK [Disabled] 此數值可以指定由 SLINK 傳播的中毒資料是否會產生延遲錯誤。設定值有: [Disabled] [Enabled] PCIe Aer Reporting Mechanism [Auto] 此數值可以選擇 PCI Express 報告 AER 錯誤的方式。當設定為 0 時,
Presence Detect Select mode [Auto] 本項目可以用來控制 Presence Detect 選擇模式。設定值有:[OR] [AND] [Auto] Preferred IO [Auto] 本項目可以選擇偏好的 IO 選擇類型。設定值有:[Bus] [Auto] Data Link Feature Cap [Auto] 本項目可以設定 Data Link Feature Capability。設定值有:[Enabled] [Disabled] [Auto]] CV test [Auto] 將本項目設定為 [Enabled] 以支援執行 PCIECV 工具。選擇 [Auto] 會保留 h/w 預設 值。設定值有:[Auto] [Disabled] [Enabled] SEV-SNP Support [Disable] 設定值有:[Disabled] [Enabled] SRIS [Auto] 設定值有:[Auto] [Disable] [Enable] FCH Common Options 以下項目僅適用於 AMD EPYC™ 7003 系列處理器。 SATA Conf
DevSleep0 Port Number [0] 本項目可以設定 DEVSLP port 0。設定值有:[0] - [7] Aggressive SATA Device Sleep Port 1 [Auto] 設定值有:[Disabled] [Enabled] [Auto] 以下項目僅當 Aggressive SATA Device Sleep Port 1 設定為 [Enabled] 時 才會出現。 DevSleep1 Port Number [0] 本項目可以設定 DEVSLP port 1。設定值有:[0] - [7] SATA Controller options SATA Controller Enable Sata0 Enable [Auto] 本項目可以啟用或關閉 Sata0。每個 IOD 有 4 Sata 控制器。設定值有: [Disabled] [Enabled] [Auto] Sata1 Enable [Auto] 本項目可以啟用或關閉 Sata1。每個 IOD 有 4 Sata 控制器。設定值有: [Disabled] [Enabled] [Auto] Sata2 Enable
以下項目僅當 Socket1 DevSlp0 Enable 設定為 [Enabled] 時才會出現。 DevSleep0 Port Number [0] 本項目可以設定 DEVSLP port 0。設定值有:[0] - [7] Socket1 DevSlp1 Enable [Auto] 僅每個 IOD/socket 的 Sata0 支援 DevSlp。設定值有:[Disabled] [Enabled] [Auto] 以下項目僅當 Socket1 DevSlp1 Enable 設定為 [Enabled] 時才會出現。 DevSleep0 Port Number [1] 本項目可以設定 DEVSLP port 1。設定值有:[0] - [7] SATA Controller SGPIO Sata0 SGPIO [Auto] 本項目可以啟用或關閉 S a t a0 的 S a t a S g p i o。設定值有:[D i s a b l e d] [Enabled] [Auto] Sata1 SGPIO [Auto] 本項目可以啟用或關閉 S a t a1 的 S a t a S g p i o。設定值有:[D
Sata7 SGPIO [Auto] 本項目可以啟用或關閉 S a t a7 的 S a t a S g p i o。設定值有:[D i s a b l e d] [Enabled] [Auto] USB Configuration Options XHCI Controller0 enable [Auto] 本項目可以啟用或關閉 USB3 控制器。設定值有:[Enabled] [Disabled] [Auto] XHCI Controller1 enable [Auto] 本項目可以啟用或關閉 USB3 控制器。設定值有:[Enabled] [Disabled] [Auto] USB ecc SMI Enable [Auto] MCM USB enable XHCI2 enable (Socket1) [Auto] 本項目可以啟用或關閉 USB3 控制器。設定值有:[Disabled] [Enabled] [Auto] XHCI3 enable (Socket1) [Auto] 本項目可以啟用或關閉 USB3 控制器。設定值有:[Disabled] [Enabled] [Auto] SD Dump
Uart Configuration Options Uart 0 Enable [Auto] Uart 0 無任何 Uart 2 啟用的 HW FC。設定值有:[Disabled] [Enabled] [Auto] 以下項目僅當 Uart 0 Enable 設定為 [Enabled] 時才會出現。 Uart 0 Legacy Options [Auto] 設定值有:[Disabled] [0x2E8] [0x2F8] [0x3E8] [0x3F8] [Auto] Uart 1 Enable [Auto] Uart 1 無任何 Uart 3 啟用的 HW FC。設定值有:[Disabled] [Enabled] [Auto] 以下項目僅當 Uart 1 Enable 設定為 [Enabled] 時才會出現。 Uart 1 Legacy Options [Auto] 設定值有:[Disabled] [0x2E8] [0x2F8] [0x3E8] [0x3F8] [Auto] Uart 2 Enable (no HW FC) [Auto] 設定值有:[Disabled] [Enabled] [Auto]
Miscellaneous Options Boot Timer Enable [Auto] [Disabled] 迫使 PMx44 bit 27 = 1。 [Enabled] 迫使 PMx44 bit 27 = 0。 [Auto] PMx44 bit 27 = PcdBootTimerEnable。 Soc Miscellaneous Control 以下項目僅適用於 AMD EPYC™ 7003 系列處理器。 ABL Console Out Control [Auto] [Disable] 關閉 ABL Console Out Control。 [Enable] 啟用 ABL Console Out Control。 [Auto] 維持預設值。 以下項目僅當 ABL Console Out Control 設定為 [Enable] 時才會出現。 ABL Basic Console Out Control [Auto] [Disable] 關閉 ABL Basic Console Out Control。 [Enable] 啟用 ABL Basic Console Out C
[Power Efficiency] 調整為最佳功率效率。 [Memory Throughput Intensive] 調整為最高記憶體流通量。 [Storage IO Intensive] 調整最高儲存 IO 頻寬。 [NIC Throughput Intensive] 調整為最大 TCP/IP 與 RDMA 網路流通量。 [NIC Latency Intensive] 調整校心執行 L3 封包的網路效能。 [Accelerator Throughput] 利用加速器,如 GPU 調整為對等網路 PCIe 流通量。 [VMware vSphere Optimized] 調整為一般 virt+P3+Q4。 [Linux KVM Optimized] 使用 Linux KVM 時調整為一般虛擬化效能。 [Container Optimized] 調整為容器效能最佳化。 [RDBMS Optimized] 調整為關聯式資料庫。 [Big Data Analytics Optimized] 調整為大資料分析。 [IOT Gat
3.5.
Parity [None] 一個 p a r i t y(同位)位元能發送資料位元來檢測一些傳輸錯誤,[M a r k] 與 [Space] parity 則不允許錯誤檢測。 [None] None。 [Even] 同位位元為 0,表示 N 個位元裡,1 出現的總次數為偶數。 [Odd] 同位位元為 0,表示 N 個位元裡,1 出現的總次數為奇數。 [Mark] 同位位元總是 1。 [Space] 同位位元總是 0。 Stop Bits [1] Stop bits 為序列資料封包的終點(開始位元表示起始)。標準設定是 1 Stop bit。使用較慢的裝置通訊可能會需要超過 1 stop bit。設定值有:[1] [2] Flow Control [None] Flow control(流量控制)能預防在緩衝區溢滿時的資料流失。當傳送資料時, 若接收的緩衝區已經滿了,此時會送出“stop”(停止)訊號來停止傳送資料流 (data flow)。當緩衝區空出時,會再送出“start”(開始)訊號以重新開始傳 送資料流。硬體流量控制使用兩條金屬線來傳送 start/stop(開始/停止)訊號。
以下選項僅當 Consloe Redirection 項目設定為 [Enabled] 時才會顯示。 Console Redirection Settings 本項目僅當 Console Redirection 設為 [Enabled] 時才能設定。這項設定說明如 何把主電腦與遠端遙控電腦(例如使用者使用的)進行檔案交換。兩部電腦都應 具備同樣或相容的設定。 Terminal Type [ANSI] 提供您設定終端類型。 [VT100] ASCII 字元設定。 [VT100+] 延伸 VT100 支援顏色、功能鍵等等。 [VT-UTF8] 使用 UTF8 加密以映像 Unicode(萬國碼)字元在 1 或更多位元 組以上。 [ANSI] 延伸 ASCII 字元設定。 Bits per second [57600] 提供您選擇序列埠傳輸速度,這速度必須與另一邊符合,過長或過多都可能會 導致速度變慢。設定值有:[9600] [19200] [38400] [57600] [115200] Data Bits [8] 設定值有:[7] [8] Parity [None] 一個 p a r i t
VT-UTF8 Combo Key Support [Enabled] 當 Terminal Type 項目設定為 [ANSI] 或 [VT100] 時,本項目才會顯示,並可以 讓您啟動或關閉在 ANSI 或 VT100 終端器下所支援的 VT-UTF8 組合碼。設定值 有:[Disabled] [Enabled]。 Recorder Mode [Disabled] 若啟用此模式則僅會傳送文字,此為擷取終端資料。設定值有:[D i s a b l e d] [Enabled] Resolution 100x31 [Enabled] 本項目用來開啟或關閉延伸終端的解析度。設定值有:[Disabled] [Enabled] Putty Keypad [VT100] 本項目提供您選擇 FunctionKey 與在 Putty 上面的 Keypad。設定值有:[VT100] [LINUX] [XTERMR6] [SCO] [ESCN] [VT400] Legacy Console Redirection Settings Legacy Console Redirection Port [COM1] 可讓您選擇
Bits per second [115200] 此為微軟 Windows Emergency Management Services (EMS) 提供 Windows Server 作業系統可以透過序列埠來採用遠端遙控管理。設定值有:[9600] [19200] [38400] [57600] [115200] Flow Control [None] 此為微軟 Windows Emergency Management Services (EMS) 提供 Windows Server 作業系統可以透過序列埠來採用遠端遙控管理。設定值有:[N o n e] [H a r d w a r e RTS/CTS] [Software Xon/Xoff] 3.5.
3.5.
SR-IOV Support [Disabled] 若系統有具備 SR-IOV 的 PCIe 裝置,本項目可以啟用或關閉支援 SIngle Root IO Virtualization 功能。設定值有:[Disabled] [Enabled] 3.5.
3.5.
3.5.
3.5.
3.5.13 SATA 設定 本選單提供 SATA 控制器及驅動程式資訊。 3.5.
3.5.
3.
SATA Partial State Capability [Enabled] 指示 HBA 是否支援轉換為局部狀態。設定值有:[Disabled] [Enabled] SATA FIS Based Switching [Enabled] 指示 HBA 是否支援埠倍增器 FIS-based switching。設定值有:[Disabled] [Enabled] SATA Command Completion Coalescing Support [Disabled] 指示 H B A 是否支援 C o m m a n d C o m p l e t i o n C o a l e s c i n g。設定值有: [Disabled] [Enabled] SATA Slumber State Capability [Enabled] 指示 HBA 是否支援轉換為睡眠狀態。設定值有:[Disabled] [Enabled] SATA Target Support 8 Devices [Disabled] 指示 SATA 目標裝置是否支援 8 個裝置。設定值有:[Disabled] [Enabled] Generi
North Bridge Socket 0 Information 本項目顯示安裝於 Socket 0 的記憶體資訊。 Socket 1 Information 本項目顯示安裝於 Socket 1 的記憶體資訊。 華碩 ESC8000A-E11 使用手冊 3-59
3.7 安全性選單(Security menu) 本選單可以讓您變更系統安全設定,並且提供您啟用或關閉安全開機(S e c u r e Boot)狀態與讓使用者設定系統模式(System Mode)狀態。 Administrator Password(設定系統管理員密碼) 請依照以下步驟設定系統管理員密碼(Administrator Password): 1. 請選擇 Administrator Password 項目並按下 。 2. 由 Create New Password 視窗輸入欲設定的密碼,輸入完成時,請按下 。 3. 請再一次輸入密碼以確認密碼正確。 請依照以下步驟變更系統管理員密碼(Administrator Password): 1. 請選擇 Administrator Password 項目並按下 。 2. 由 Enter Current Password 視窗輸入密碼並按下 。 3. 由 Create New Password 視窗輸入新密碼,輸入完成按下 。 4.
User Password(設定使用者密碼) 請依照以下步驟設定使用者密碼(User Password): 1. 請選擇 User Password 項目並按下 。 2. 由 Create New Password 視窗輸入欲設定的密碼,輸入完成時,請按下 。 3. 請再一次輸入密碼以確認密碼正確。 請依照以下步驟變更使用者密碼(User Password): 1. 請選擇 User Password 項目並按下 。 2. 由 Enter Current Password 視窗輸入密碼並按下 。 3. 由 Create New Password 視窗輸入新密碼,輸入完成按下 。 4. 請再一次輸入密碼以確認密碼正確。 請依照以下步驟刪除使用者密碼(User Password): 1. 請選擇 Clear User Password 項目並按下 。 2.
Restore Factory Keys 此項目將強迫系統進入 User Mode,並安裝出廠預設安全開機金鑰資料。 Reset to Setup Mode 此項目將會刪除 NVRAM 中的所有開機金鑰資料。 Key Management 本項目僅當 Secure Boot Mode 設定為 [Custom] 時才會顯示,提供您修改 Secure Boot(安全開機)變量與設定 Key Management(密鑰管理)頁面。 Factory Key Provision [Disabled] 本項目可以在系統為 S e t u p M o d e 時提供您系統預設安全啟動變量。設定值 有:[Disabled] [Enabled] Restore Factory keys 本項目會安裝所有系統預設安全變量。 Reset to Setup Mode 本項目僅當您設定原廠預設金鑰時才會出現。本項目可以讓您刪除所有金鑰回 復 Setup Mode。 Export Secure Boot Variables 本項目會詢問您是否要儲存所有安全啟動變量。選擇 Y e s 以儲存,或是選擇 No 放棄。 Enro
Restore DB defaults 將 DB variable 還原為出廠預設值。 Platform Key (PK) 設定值有:[Details] [Export] [Update] [Delete] Key Exchange Keys (KEK) / Authorized Signatures (DB) / Forbidden Signatures (DBX) 設定值有:[Details] [Export] [Update] [Append] [Delete] Authorized TimeStamps (DBT) / OsRecovery Signatures 設定值有:[Update] [Append] 3.
Boot Option Priorities 這些項目為列出目前可用的開機裝置優先順序。螢幕上顯示的裝置數量即為根據您 在系統中所安裝的裝置數量。 • 若要在開機過程中選擇開機裝置,請於開機看到 ASUS 圖示時按下 鍵 • 您可以在 POST(開機自我測試)時,按下 鍵進入 Windows 作 業系統的安全模式(Safe Mode)。 POST Report [5 sec] 提供您設定想要的 POST(開機自我測試)回報等待時間,可選擇從 1 至 10 秒。設定值有:[1 sec] ~ [10 sec] [Until Press ESC] 3.
3.
3.11 事件記錄選單(Event Logs menu) 3.11.
Smbios Event Log Standard Settings Log System Boot Event [Disabled] 本項目可開啟或關閉記錄系統啟動事件。設定值有:[Disabled] [Enabled] MECI [1] 允許您調整 MECI 的設定值。使用 <+> 或 <-> 鍵調整數值。設定值有:[1] - [255] METW [60] 允許您調整 METW 的設定值。使用 <+> 或 <-> 鍵調整數值。設定值有:[0] - [99] Custom Options Log EFI Status Code [Enabled] 允許您開啟或關閉 EFI 狀態編碼記錄。設定值有:[Disabled] [Enabled] 以下的項目僅當 Log EFI Status Code 設定為 [Enabled] 時才會出現。 Convert EFI Status Codes to Standard Smbios Type [Disabled] 允許您開啟或關閉 EFI 狀態編碼轉變為標準 Smbios 編碼(不是所有都可以轉換) 。設定值有:[Disabled] [Enabled]。 3
3.
System Event Log 提供您變更 SEL 事件記錄設定。 Erase SEL [No] 提供您選擇清除 SEL 的選項。設定值有:[No] [Yes, On next reset] [Yes, On every reset] 所有變更的數值需電腦重新開機會才會生效。 BMC network configuration 在此子選單裡的項目可以提供您設定 BMC 區域網路參數。 Configure IPV4 support DM_LAN1/Shared LAN Configuration Address source [Previous State] 選擇設定的網路通道的參數為靜態或動態(透過 BIOS 或 BMC)。未指定選項 將不會修改在 BIOS 裡的任何 BMC 網路參數。設定值有:[Previous State] [Static] [DynamicBmcDhcp] 以下項目僅當 Configuration Address source 設為 [Static] 時才會顯示。 Station IP address 本項目可以設定站台 IP 位址。 Subnet mask 本項目可以設定
Configuration Address source [Previous State] 選擇設定的網路通道的參數為靜態或動態(透過 BIOS 或 BMC)。未指定選項 將不會修改在 BIOS 裡的任何 BMC 網路參數。設定值有:[Previous State] [Static] [DynamicBmcDhcp] 以下項目僅當 Configuration Address source 設為 [Static] 時才會顯示。 Station IPV6 address 本項目可以設定站台 IPV6 位址。 Prefix Length 本項目可以設定前置位元長度(最多為 128)。 Configuration Router LAN1 Address [Previous State] 選擇設定的網路通道的參數為靜態或動態。 View System Event Log 可以檢視系統事件記錄。 3-70 第三章:BIOS 程式設定
安裝驅動程式 本章提供主機板相關之驅動程式的安裝說明。 4
4.1 安裝應用程式與工具程式 驅動及公用程式光碟裡提供您主機板相關的驅動程式、管理應用程式與工具程式, 可以讓您將主機板功能最佳化。 驅動及公用程式 DVD 光碟裡的內容如有變更,恕不另行通知。請造訪華 碩網站(https://www.asus.com/tw/)以更新最新的軟體與工具程式。 在驅動及公用程式 DVD 光碟的主選單裡有以下幾個標籤頁: 1. Drivers - 驅動程式主選單提供了您目前需要安裝的一些硬體驅動程式。 2. Utilities - 工具軟體選單顯示了可安裝於此系統的應用軟體與工具。 3. Manual - 使用手冊選單提供您使用手冊的開啟連結。 您需要在作業系統中使用網路瀏覽器軟體才能開啟使用手冊。 4.
附錄 在本附錄裡將列出相關的聯絡資訊。
ESC8000A-E11 架構圖 A-2
Q-Code 列表 Code 00 02 03 04 06 10 11 – 15 – 19 – 2B – 30 31 32 – 37 – 3B – 4F 50 – 14 18 1C 2F 36 3A 3E 53 4F 54 55 56 57 58 59 5A 5B 5C – 5F E0 E1 E2 E3 E4 – E7 E8 E9 EA EB EC – EF F0 F1 F2 F3 F4 F5 – F7 F8 F9 Description Not used microcode CACHE_ENABLED PCH initialization CPU_EARLY_INIT PEI Core is started Pre-memory CPU initialization is started Pre-memory System Agent initialization is started Pre-memory PCH initialization is started Memory initialization Reserved for ASL (see ASL Status Codes sectio
Q-Code 列表(續上頁表格) Code FA FB – FF 60 61 62 63 – 67 68 69 6A 6B – 6F 70 71 72 73 – 77 78 79 7A – 7F 90 91 92 93 94 95 96 97 98 99 9A 9B 9C 9D 9E – 9F A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 AA AB A-4 Description Invalid recovery capsule Reserved for future AMI error codes DXE Core is started NVRAM initialization Installation of the PCH Runtime Services CPU DXE initialization is started PCI host bridge initialization System Agent DXE initialization is started System Agent DXE SMM initialization is started System Agent
Q-Code 列表(續上頁表格) Code AC AD AE AF B0 B1 B2 B3 B4 B5 B6 B7 B8– BF D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 DA DB DC Description Reserved for ASL (see ASL Status Codes section below) Ready To Boot event Legacy Boot event Exit Boot Services event Runtime Set Virtual Address MAP Begin Runtime Set Virtual Address MAP End Legacy Option ROM Initialization System Reset USB hot plug PCI bus hot plug Clean-up of NVRAM Configuration Reset (reset of NVRAM settings) Reserved for future AMI codes CPU initialization error System Ag
服務與支援 請造訪 https://www.asus.