12.4.3.13 Set Configuration Register
This command allows setting some configuration registers just in time; no reset is
needed. The values are not stored in the EEPROM; therefore the changed values
are not available after a reset.
Command
Command Data
og Register type (1 byte)
data (1 byte)
Answer
Answer Description
Data (1 byte) Current state of changed register.
'R' Error: Out of range
Example
Command Description
og0450 Answer: 50
Sets the Reset Recovery Time to 50h.