MODEL 90 M 90 M-T 110 M 110 M-T
1 Data in heating mode: heat exchanger entering/leaving water temperature 30 °C/35 °C, outside air temperature 7 °C db/6 °C wb
2 Nominal heating capacity (HEO) kW 8,49 8,49 10,40 10,40
3 Power input kW 1,66 1,66 2,08 2,08
COP kW/kW 5,10 5,10 5,00 5,00
2 Nominal heating capacity (HPO) kW 13,60 13,60 15,00 15,00
3 Power input kW 2,96 2,96 3,33 3,33
COP kW/ kW 4,60 4,60 4,50 4,50
1 Data in heating mode: heat exchanger entering/leaving water temperature 30 °C/35 °C, outside air temperature 2 °C db/1 °C wb
2 Nominal heating capacity kW 6,69 6,69 8,00 8,00
3 Power input kW 1,67 1,67 1,93 1,93
COP kW/kW 4,01 4,01 4,15 4,15
1 Data in heating mode: heat exchanger entering/leaving water temperature 30 °C/35 °C, outside air temperature -7 °C db/-8 °C wb
2 Nominal heating capacity kW 9,10 9,10 11,00 11,00
3 Power input kW 2,80 2,80 3,49 3,49
COP kW/kW 3,25 3,25 3,15 3,15
4 Data in cooling mode: heat exchanger entering/leaving water temperature 23 °C/18 °C, outside air temperature 35 °C
5 Nominal cooling capacity kW 10,55 10,55 12,50 12,50
3 Power input kW 2,17 2,17 2,74 2,74
EER kW/kW 4,86 4,86 4,56 4,56
6 Data in heating mode: heat exchanger entering/leaving water temperature 40 °C/45 °C, outside air temperature 7 °C db/6 °C wb
2 Nominal heating capacity kW 8,16 8,16 9,90 9,90
3 Power input kW 2,08 2,08 2,64 2,64
COP kW/kW 3,93 3,93 3,75 3,75
6 Data in heating mode: heat exchanger entering/leaving water temperature 40 °C/45 °C, outside air temperature 2 °C db/1 °C wb
2 Nominal heating capacity kW 6,25 6,25 7,50 7,50
3 Power input kW 2,05 2,05 2,36 2,36
COP kW/kW 3,05 3,05 3,19 3,19
6 Data in heating mode: heat exchanger entering/leaving water temperature 40 °C/45 °C, outside air temperature -7 °C db/-8 °C wb
2 Nominal heating capacity kW 8,60 8,60 10,45 10,45
3 Power input kW 3,29 3,29 4,10 4,10
COP kW/kW 2,62 2,62 2,55 2,55
7 Data in cooling mode: heat exchanger entering/leaving water temperature 12 °C/7 °C, outside air temperature 35 °C.
5 Nominal cooling capacity kW 9,05 9,05 11,00 11,00
3 Power input kW 2,87 2,87 3,75 3,75
EER kW/kW 3,15 3,15 2,93 2,93
9 Type of refrigerant R-410A
10 Compressor DC twin-rotary
11 Expansion valve PMV
12 Water connections, inlet/outlet (MPT gas) in 1
HEO: High Efficiency Operation
HPO: High Power Operation