Aquor House Hydrant V1+ ® FAUCET KIT Scan to watch install video.
Aquor House Hydrant V1+ Faucet Kit OVERVIEW ® 3 ASSE 1019C / ASME A112.18.1 / CSA B125.1 / AS/NZS3718 CERTIFIED Overview Aquor House Hydrant V1+ The Aquor House Hydrant is a flush-mounted hydrant with twist-lock connection system designed for outdoor use. The hydrant is intended to be installed in the exterior walls of homes and buildings. Upon disconnection, a small amount of water self-drains from the outlet.
Aquor House Hydrant V1+ Faucet Kit TECHNICAL SPECS ® 5 ASSE 1019C / ASME A112.18.1 / CSA B125.1 / AS/NZS3718 CERTIFIED Technical Specs In the Box Hydrant, Debris Cover, Hose Connector, x3 #10 Mounting Screws, Install Instructions Backflow Protection Yes, built-in vacuum breaker Inlet x Outlet 1/2 “ NPT (f) x 3/4” GHT (m) Operating Temperature 33 -140 °F Operating Water Pressure 25-125 PSI SKU Stem Length (A) Overall Length (B) Flow Rate 6.
Aquor House Hydrant V1+ Faucet Kit PARTS DESCRIPTION ® 7 ASSE 1019C / ASME A112.18.1 / CSA B125.1 / AS/NZS3718 CERTIFIED 9 8 7 A 1 2 3 4 10 5 6 B 11 12 Parts Description Hydrant A 1. Rear Valve Housing (inlet) 2. Valve Return Spring 3. Hydrant Body O-Ring 4. Main Valve O-Ring 5. Operating Rod 6. Hydrant Body Debris Cover 7. Debris Cover Gasket 8. Debris Cover Wedge 9. Debris Cover Nut & Bolt 10. Debris Cover B Hose Connector 11. Connector O-Rings 12.
Aquor House Hydrant V1+ Faucet Kit ® INSTALLATION 9 ASSE 1019C / ASME A112.18.1 / CSA B125.1 / AS/NZS3718 CERTIFIED Installation Determine the location for the hydrant. The hydrant’s inlet must be installed into a heated area of the structure that will not drop below freezing. Before installation, make sure there is adequate work room for securing the hydrant to the supply line. 1 . P R E PA R E WA L L Prepare the mounting surface and entry hole.
Aquor House Hydrant V1+ Faucet Kit ® INSTALLATION 11 ASSE 1019C / ASME A112.18.1 / CSA B125.1 / AS/NZS3718 CERTIFIED With the cover wedge behind the faceplate flange secure the hydrant to the wall. x3 #10 1.5" stainless steel screws are provided. Cover wedge behind faceplate With the appropriate fitting installed, re-attach the inlet to the hydrant body. Tip: Drilling into brick or stone? Consider using specialized fasteners and/or anchors.
Aquor House Hydrant V1+ Faucet Kit INSTALLATION & OPERATION 13 ® ASSE 1019C / ASME A112.18.1 / CSA B125.1 / AS/NZS3718 CERTIFIED Depending on the type of plumbing, it will vary how the hydrant connects. Common ways of connecting to copper plumbing include soldering and push-fit adapters. Tip: With copper plumbing, consider securing the hydrant's inlet against a stud. This way the hydrant can be removed from the building's exterior if ever needed.
Aquor House Hydrant V1+ Faucet Kit ® OPERATION 15 ASSE 1019C / ASME A112.18.1 / CSA B125.1 / AS/NZS3718 CERTIFIED Connect: Line up the three helical grooves on the hose connector with the three nibs on the hydrant faceplate. Simultaneously push and twist the connector clockwise in a smooth motion. Make sure to align the grooves fully and push in before twisting. Water flow will start instantly when the connector is engaged (see image below).
Aquor House Hydrant V1+ Faucet Kit ® MAINTENANCE 17 ASSE 1019C / ASME A112.18.1 / CSA B125.1 / AS/NZS3718 CERTIFIED Maintenance Aquor ® hydrants leave the factory fully tested and operational. They are treated with an FDA approved lubricant where needed. The hydrant requires no scheduled maintenance to provide a long operational life. If a problem does arise, all the serviceable components are offered in repair kits.
Aquor House Hydrant V1+ Faucet Kit TROUBLESHOOTING 19 ® ASSE 1019C / ASME A112.18.1 / CSA B125.1 / AS/NZS3718 CERTIFIED Troubleshooting PROBLEM SOLUTION No water flow when connected. First you’ll want to identify whether the issue is in the hydrant of the hose connector. Make sure water supply is live to the hydrant. Try depressing the hydrant valve with your thumb to test for pressure. If the water pressure is live, the issue is likely the hose connector.
Aquor House Hydrant V1+ Faucet Kit TROUBLESHOOTING 21 ® ASSE 1019C / ASME A112.18.1 / CSA B125.1 / AS/NZS3718 CERTIFIED PROBLEM SOLUTION Water leaking from the hydrant main outlet (front) when connected. Inspect hose connector O-rings for damage, replace or lubricate if needed. Water leaking from the hydrant main outlet when disconnected. A slow leak may indicate a stuck or bent internal rod, or damaged O-ring. First, try to reset the valve from the front.
Aquor House Hydrant V1+ Faucet Kit ® TROUBLESHOOTING, WARRANTY, & CONTACT 23 ASSE 1019C / ASME A112.18.1 / CSA B125.1 / AS/NZS3718 CERTIFIED PROBLEM SOLUTION Hose connector is difficult to connect or disconnect. Try squeezing your hose nozzle while simultaneously disconnecting. If left outdoors in variable weather, water expansion may have caused the connector’s internal check-valve to seize. Try disassembling or removing the connector’s check valve. Test with a different hose connector.
Aquor Water Systems Inc. 240 Airport Rd, Port Townsend, WA 98368 contact@aquorwatersystems.