Specification

Customer Service: 800.945.2726 • aquaticbath.com
TECHNICAL SPECIFICATIONS
Customer Service: 800.945.2726 • aquaticbath.com
FEATURES Dimensional Tolerance ± 38”.Dimensions needed for site preparation should be measured from the unit.Manufacturer assumes no responsibility for preparatory work.
Type and Model # Material System Powered By Heater Controls Drain
Pkg. Wt.
lbs
Soaker #W2AIR7042TO Acrylic Center Front 184
Soaker w/ABS base #AI1AIR7242TO Acrylic Center Front 199
HotSoak #AI1AIR7242HS Acrylic
Water
circulation
Pump
1.5 kW Inline
maintenance
Electronic Center Front 229
Air Bath #AI1AIR7242 Acrylic Air bath Variable speed blower Integrated Electronic Center Front 229
DriftBath #AI1AIR7242DB Acrylic
Water
circulation
Pump Integrated Electronic Center Front 240
DIMENSIONS inches
Width Depth Height
Skirt
Height
71
1
4 41
3
4 24
1
2
SUMP DATA inches
Capacity to
Overflow
gal
DriftBath Min.
Operating Cap.
gal
WIDTH @ centerline DEPTH @ centerline
Top Bottom Top Bottom
90 62 62
1
2 44 26
1
2 22
1
2
ELECTRICAL DATA
Component Specification Requirement
Heated Blower (Air Bath) 10.5 AMP; 120V
15 AMP; 120V, separate circuit;
Class A GFCI
Pump (HotSoak)
1
15 HP; 1.3 AMP; 120V
20 AMP; 120V, separate circuit;
Class A GFCI
Heater (HotSoak) 1.5 kW; 12 AMP; 120V
Pump (DriftBath)
3
4 HP; 8.8 AMP; 120V
15 AMP; 120V, separate circuit;
Class A GFCI
Each Serenity air bath is equipped with an air heating system to raise the temperature of the air
entering the bath. This air temperature will be lower than the bathing temperature of the water,
but will help reduce rapid decrease in water temperature. In addition, the air coming from the
air jets will feel cool against the skin. This system does not heat the water.
Note: Drop-in Serenity models feature
a Pre-leveled ABS support base.
(Soakers feature a pre-leveled wood
base as standard.)
Rev. 06.28.16
PLUMBING DIMENSIONS inches
A B
Drain
Diameter / Clearance
6
1
4 12
3
4
2 / 2
1
4
NOTES:
1) Where applicable, utilize cut-out templates packed with unit for
deck cutouts.
2) 16 x 16 minimum access required at pump/blower location(s).
3) For low profile deck, framing height will need to be increased
by an additional 1”.
4) If a (3T) tiling flange is selected, then the keypad is located
opposite of the flange.
SERENITY 1
71
1
4 x 41
3
4 x 24
1
2
71 1/4"
1
2
41 3/4
"
22 1/2"
26 1/2"
60°
18 3/4"
24 1/2"
A
18”
B
44"
62 1/2"
22 1/2"
Tub-mounted Faucetry
– Suggested locations
Keypad for pump location 1
Keypad for pump location 2