PREMIER SERIES DRINKING WATER SYSTEM OWNER’S MANUAL FOR MODEL NO.
TABLE OF CONTENTS 2 2 4 5 6 7 INSPECTION & PREPARATION Be Familiar with the System Before Installation System Operation Parameters and Installation checklist Feed Water Adapter with 3/8” or 1/2” Connection Setup Quick Connect / Compression Fitting Installation Instruction Drinking Water Faucet Mounting Hole Preparation 10 10 12 13 13 14 15 16 INSTALLING THE SYSTEM STEP1. Feed Water Adapter Installation STEP 2. Drain Saddle Installation STEP 3. Tank Ball Valve Installation STEP 4.
WELCOME Thank you for choosing Aquasure. Before you start using your Aquasure drinking water system, take a few minutes to become familiar with the basics. Filter replacement Be sure to change your Aquasure water filters according to the recommended filter replacement schedule. This helps keep your Aquasure drinking water system running in top condition.
Dia.
II. System Operation Parameters and Installation checklist IMPORTANT! The following conditions for the feed water supply must be met or warranty will be void and manufacturer assumes no responsibility for damage to system or property. 1. Water Temperature Parameters • • Maximum: 105º F (40.6º C) Minimum: 33º F (0.55º C) WARNING: Do not allow the system to freeze, the membrane always contains water and will be destroyed if frozen.
5. System Dimensions & Specifications IMPORTANT! Please make sure there is sufficient space for the system to be installed properly. It is best to first place the system in the space to see if there is room for the system to be mounted and installed properly. Do not install the system in an area where it is exposed to extreme hot and/or cold weather or under direct sunlight. WARNING: It is recommended to mount the system on the wall with the correct screws appropriate for the mounting location.
IV. Quick Connect / Compression Fitting Installation Instruction Note: This systems is equipped with quick connect fittings. These user-friendly fittings provide superior performance and leak-free seal if installed correctly. 1. Quick Connect Tubing Installation • • • Dia. C-1 CORRECT Inspect Tubing (See Diagram C-1) - The system comes with pre-cut tubing that is cut cleanly and squarely to ensure proper connection.
3. Optional Compression Nut Fitting (See Diagram B-5) • Slip the compression nut onto the tubing. • Slide the plastic sleeve onto the tubing • Place the insert inside the tubing • Slide the compression nut up and tighten it onto the flange using a wrench. Dia. C-5 Tube Nut Sleeve Insert V. Drinking Water Faucet Mounting Hole Preparation IMPORTANT! Extreme care must be taken in drilling the hole for the dispensing faucet.
4. Drilling Stainless Steel • • • • • • • Use a hole punch and hammer to mark the location of where you want to install the faucet. Keep your taps short and control until a dent is visible, this will help keep your drill bit seated when start drilling. Apply lubricant to the drill area as drilling at high speed will create a lot of heat which can cause the metal to warp or burn. Using the ¼” (6mm) drill bit, at half speed to drill the hole. This would help prevent it from overheating.
AQUASURE PREMIER SERIES 9
INSTALLING THE SYSTEM WARNING! Do not proceed with the installation until you have gone over the System Operation Parameters and Installation Checklist section on page 4 of this owners manual and comply with all the conditions listed in that section. Failure to comply may result in property damage and your system warranty will be voided due to non-compliance with the operation parameters. IMPORTANT! Locate and test the main water supply valve to the house before installing the system.
Test For Leaks: 1. Make sure the feed water adapter is in the shut-off position, perpendicular to the feed connection (See Diagram D-2) Dia. D-2 2. Turn on the cold water supply to the sink faucet. 3. Check for leaks Note: If there’s a water leak, check the connection and apply more Teflon or tighten the connection more to stop the leak. Optional connection for connecting on Solid Copper Riser with Self-Piercer (Sold Separately): (See Diagram D-3) 1.
STEP 2. Drain Saddle Installation 1. Locate the optimal placement on the drain pipe to install the drain saddle. (See Diagram E-1) Note: The drain saddle should be installed above the trap and on the vertical or horizontal tail piece. To reduce potential drainage noise, it is ideal to mount the drain saddle as low as possible on the vertical pipe above the trap or on the horizontal tail piece.
STEP 3. Tank Ball Valve Installation (See Diagram F-1) 1. Attached the tank ball valve on top of the tank. Dia. F-1 CAUTION! Do Not over tighten the adapter to avoid breaking and leak. STEP 4. Drinking Water Faucet Installation (See Diagram G-1) 1. Place the faucet base over the drilled hole and make sure the hole is completed covered by the faucet base. 2. Insert the faucet shank through the faucet base and drilled hole completely. 3.
STEP 5. Mounting or Placement of the System WARNING! If mounting the system is not an option, please make sure system is installed in a space with secure footing. Improper placement of the system may cause the system to tip over and break due to the added weight of the water. 1. Position the system on the wall at the desired mounting location 3 - 4 inches from the cabinet floor to the base of the system.
STEP 6. Connecting the System (See Diagram I-1) Note: Remove all end plugs from the system by following the fitting-removal instruction on page 6, and please follow the proper fitting installation instruction to prevent any possible leak. IMPORTANT! Be careful not to kink any of tubing on the system as kinked tubing can rupture and leak. 1. Connect the WHITE color-coded tubing from the SHOKBLOK protection valve (A) to feed water adapter (B) 2.
STEP 7. System Startup WARNING! Immediately shut off the cold water supply valve or main water supply valve if there are leaks. Check the leak area and see if there’s a loose connection or if more Teflon tape is needed to prevent leaks from happening. 1. Turn on the feed water adapter valve and cold water supply valve to allow the water to pass through. (See Diagram J-1) 3. Turn on the Tank Ball Valve lever parallel to the tubing connection to allow the water to enter the tank. (See Diagram J-3) Dia.
Mount the system onto the wall or placed in a secure location. Dia. J-5 Turn off the FLOWLOK™ lever and insert the compressed safety disc inside the holder and turn the lever back on. (See Diagram J-5) Turn off the drinking water faucet to let the water storage tank replenish the product water. Disc Holder Check one last time on all the connections and joints to make sure there’s no leak. Safety Disc CONGRATULATIONS! You have finished installing your very own drinking water system.
SYSTEM MAINTENANCE Note: The system requires very little maintenance as long as the filter cartridges are regularly replaced at the recommended time frame. Please only use genuine Aquasure replacement filter at http://www.aquasureusa.com/water-filter/drinking-water/premier Filter Replacement Time Frame • Pre-Stage Filters: Replace every 6 to 12 months (Private well water source may need to replace pre-filters sooner than 12 months due to heavy sediments and other particulates.
II. Replacing Stage 1 & 2 Pre-Filters 1. Turn OFF tank’s ball-valve. (See Diagram L-1) 4. Twist the Pre-Stage Filters quarter turn to the right to unseat the filters from the system. (See Diagram L-4) Dia. L-4 Dia. L-1 2. Turn OFF cold water supply from feed water adapter to the system. (See Diagram L-2) Dia. L-2 5. Replace the system with new Pre-Stage Filters by setting them on to the system and twisting them quarter turn to the left. (See Diagram L-5) Dia. L-5 3.
III. Replacing Stage 3 & 4 RO membrane and Post Carbon Filter 1. Turn OFF cold water supply from the feed water adapter to the system. 5. Twist the RO-Membrane and Post-Stage Taste Refining Filter quarter turn to the right to unseat the filters from the system. 2. Turn on the dispensing faucet to empty out the tank and store all the product water in a spare water container for usage. 6.
AQUASURE PREMIER SERIES 21
SYSTEM TROUBLESHOOTING IMPORTANT! Please shut off cold water supply valve to the system if the system is malfunctioning or leaking and contact our support department immediately! For any system troubleshooting, feel free to contact our support department at 1-800-661-0680 during our business hour of Monday - Friday from 8:30 am ~ 5:30 pm PDT. You can also e-mail us at support@aquasureusa.com or visit us on the web at http://www.aquasureusa.com/support for all the latest update and support. 1.
3. Low water pressure from dispensing faucet CAUSE: CORRECTION: A Air pressure in holding tank is incorrect. This is the #1 reason for low flow from reverse osmosis system. Open faucet and empty water from holding tank. Shut off feed water to system and remove holding tank from under sink. Locate the air valve stem and add air. If there’s still water in the tank, continue to add air until all the water is removed. Once all the water is removed, continue to add air and pressurize to 8 psi.
6. Faucet leaks or drips CAUSE: CORRECTION: A Water leaks from faucet spouts Adjust the faucet by turning the tee bar located under the handle to provide a small amount of free play in the handle when shut off. Should this not work, repair or replace the faucet. B Water leaks from beneath the handle Repair or replace the faucet. 7. Little to no water at dispensing faucet. CAUSE: CORRECTION: A Water is shut off at stop valve Open main stop valve.
11. System does not shut off CAUSE: CORRECTION: A Automatic shut-off valve is defective Test the functionality of automatic shut-off valve by closing the tank ball valve to see if the system will shut off. If the system continues producing water, the automatic shut-off valve is defective and needs to be replaced. B Automatic shut-off valve is not defective and incoming water pressure is too low Incoming water pressure must be above 40 psi. Install a booster pump or permeate pump.
LIMITED PRODUCT WARRANTY Scope: Aquasure takes pride in selling a superb line of products, including this drinking water system (“Product”). As such, Aquasure expressly warrants to the original purchaser that, for a period of one (1) year from the date of purchase, the product will be reasonably free of defects in materials and workmanship.
4. Damage not resulting from manufacturing defects that occur while the Product is in the original purchaser’s possession. 5. Installation of the Product with known or visible manufacturing defects at the time of installation. 6. Damage caused by freezing, flood, fire or Act of God. Condition that render this limited product warranty void THIS LIMITED PRODUCT WARRANTY SHALL BE VOID IF: 1.
www.AquasureUSA.com | 818 N Mountain Ave #203c, Upland, CA 91786 | 800.661.0680 | sales@aquasureusa.