Specification

Performance Data Sheet for the EQ-300 Aquasana Whole House Rhino
®
Water Filter System
Models Replacement Max Operating pressure Rated capacity Operating temp. range Rated ow
EQ-300 / EQ-301
EQ-300R
100 psi 300,000 gallons 40-90º F 7.0 gpm
Manufactured by: Aquasana, Inc. 6310 Midway Road · Haltom City, Texas 76117 · 866-662-6885
For use with municipally treated water only. Do not use with water that is microbiologically unsafe or of
unknown water quality without adequate disinfection before or after the system.
Filter is only to be used with cold water.
Filter usage must comply with all state and local laws.
Testing was performed under standard laboratory
conditions, actual performance may vary.
All contaminants reduced by this lter are listed.
• Not all contaminants listed may be present in your water.
• Does not remove all contaminants that may be present in tap water.
Testing Performed under NSF/ANSI Standards 42 for reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit
for water leaving the system, as specied in NSF/ANSI 42.
System Tested and Certied by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine
Taste and Odor.
NSF/ANSI 42
Inuent Challenge
Chlorine
Pressure drop
Minimum
reduction
Overall %
reduction
Results
Chlorine Reduction, Free Available 2 mg/L ±10% 10.5 psi ≥50% >97.1 % Pass
Data Summary Table
Sample
Point
Accumulated
Volume (gal)
Dynamic Pressure
(psi)
Chlorine, Free Available
(mg/L)
Flow Rate (gpm)
Euent 1 Inuent Inuent Euent 1 Euent 1
Startup 150 62 1.9 ND (0.05) 7.2
10% 30,000 62 2.1 0.07 7.1
20% 60,000 62 2.0 ND (0.05) 7.1
30% 90,000 62 1.9 ND (0.05) 7.1
40% 120,000 62 2.1 ND (0.05) 7.2
50% 150,000 62 2.0 ND (0.05) 7.1
60% 180,000 61 1.8 ND (0.05) 7.0
70% 210,000 62 2.1 ND (0.05) 7.1
80% 240,000 61 2.0 ND (0.05) 7.1
90% 270,000 60 2.0 ND (0.05) 7.1
100% 300,000 61 2.1 0.11 7.0
Systems certied for cyst reduction may be
used on disinfected waters that may contain
lterable cysts.
See owner’s manual for general installation
conditions and needs plus manufacturer’s
limited warranty.

Summary of content (1 pages)