R INSTALLATION AND OPERATING INSTRUCTIONS Models: FD, FDD, FDL & FDDL OVERHEAD WARMERS INTENDED FOR OTHER THAN HOUSEHOLD USE RETAIN THIS MANUAL FOR FUTURE REFERENCE UNIT MUST BE KEPT CLEAR OF COMBUSTIBLES AT ALL TIMES ! FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. ! ! WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death.
TABLE OF CONTENTS SECTION PAGE ITEM 1 Owner’s Information General Information Installation Instructions General Operation Instructions Warranty Information 2 2 3 4 4 2 Important Safety Information 4 3 Specifications Electrical Dimensions 4 4 5 4 Operation Operating Instructions 6 6 5 Cleaning General Cleaning Instructions 6 6 6 Troubleshooting 6 7 Wiring Diagrams.
Do not install closer than: A = Minimum clearance (in inches) to Bottom Surface of unit from Tabletop B = Minimum clearance (in inches) to Back of unit. C = Minimum clearance (in inches) to Sides of unit.
General Operation Instructions: 1. All foodservice equipment should be operated by trained personnel. 2. Do not allow your customers to come in contact with any surface labeled “CAUTION HOT”. 3. Never hold food below 150°F (66°C). Warranty Information: Reliability Backed By APW Wyott’s Warranty: All APW Wyott Overhead Warmers are backed by a one year parts and labor warranty, including On-Site Service calls within 50 miles of authorized service technicians.
! WARNING: ELECTRICAL SHOCK HAZARD. FAILURE TO FOLLOW THE INSTRUCTIONS IN THIS MANUAL COULD RESULT IN SERIOUS INJURY OR DEATH. ! Electrical Ground is required on this appliance. Do not modify the power supply cord plug. If it does not fit into the outlet, have the proper outlet installed by a qualified electrician Do not use an extension cord with this appliance. Check with a qualified electrician if you are unsure as to whether the appliance is properly grounded.
4. Operation A. All foodservice equipment should be operated by trained personnel. B. Do not allow your customers to come in contact with any surface labeled “CAUTION HOT”. C. Switch on unit. Place precooked product under heat source. Maximum heat coverage equivalent to unit length. D. Never hold food below 150ºF. 5. Cleaning General Cleaning Instructions: A. Never clean any electrical unit by immersing it in water. Turn off before surface cleaning. B. Never clean any electrical unit using water jets. C.
. WIRING DIAGRAMS FD18-72 WIRING DIAGRAM REMOTE CONFIGURATION ELEMENT G GREEN 120V: WHITE 200-240V: BLUE BROWN INFINITE CONTROL CONFIGURATION HEATING ELEMENT DISPLAY LIGHT INDICATOR LIGHT L2 120V: WHITE BROWN GREEN L2 200-240V: BLUE L1 L2 G H2 H1 PILOT L1 EGO INFINITE CONTROL L1 INFINITE CONTROL P L1 L2 H1 H2 ELEMENT PILOT LIGHT BLUE BROWN TOGGLE SWITCH CONFIGURATION 120V: WHITE 200-240V: BLUE GREEN BROWN G L1 L2 TOGGLE SWITCH ELEMENT PILOT LIGHT BLUE BROWN 67177 REV-11/2001 7
FDL18-72 WIRING DIAGRAM REMOTE CONFIGURATION ONE LAMPHOLDER 18,24,30 MODELS TWO LAMPHOLDERS 36,42,48,54 MODELS BLACK WHITE BLACK WHITE BLUE 6 4 120V: WHITE 200-240V: BLUE L1 5 BROWN G 1 N/L2 2 L1 3 FOUR LAMPHOLDERS 84,96 MODELS BLACK WHITE BLUE 6 7 LABELS N/L2 THREE LAMPHOLDERS 60,66,72 MODELS WHITE BLACK BLUE 6 7 7 ELEMENT GREEN 120V: WHITE 200-240V: BLUE BROWN INFINITE CONTROL CONFIGURATION HEATING ELEMENT DISPLAY LIGHT INDICATOR LIGHT L2 L2 H2 H1 L1 PILOT FOUR LAMP
FDD18-72 WIRING DIAGRAM REMOTE CONFIGURATION ELEMENT 120V: WHITE 200-240V: BLUE LABELS N/L2 BROWN L1 GREEN G ELEMENT 120V: WHITE 200-240V: BLUE N/L2 BROWN L1 INFINITE CONTROL CONFIGURATION ELEMENT P L1 L2 H1 H2 PILOT LIGHT LABELS N/L2 L1 G BLUE 200-240V: BLUE 120V: WHITE BROWN HEATING ELEMENT DISPLAY LIGHT BROWN INDICATOR LIGHT GREEN L2 L2 ELEMENT P L1 L2 H1 H2 H1 PILOT LIGHT PILOT BLUE BROWN TOGGLE SWITCH CONFIGURATION LABELS 9 H2 L1 EGO INFINITE CONTROL L1
FDDL18-72 WIRING DIAGRAM REMOTE CONFIGURATION ELEMENT 120V: WHITE LABELS N/L2 200-240: BLUE BROWN L1 1 LAMPHOLDER 2 LAMPHOLDERS 3 LAMPHOLDERS 18,24,30 MDLS 36,42,48,54 MDLS 60,66,72 MDLS WHITE WHITE BLACK WHITE BLACK BLUE 4 LAMPHOLDERS 84,96 MDLS WHITE BLACK BLACK BLUE BLUE 120V: WHITE N/L2 200-240: BLUE BROWN L1 ELEMENT GREEN G 120V: WHITE N/L2 200-240: BLUE BROWN L1 INFINITE CONTROL CONFIGURATION INFINITE CONTROL ELEMENT P L1 L2 H1 H2 PILOT LIGHT BROWN LABELS N/L2 L1
8.
FD18 THRU 96 OVERHEAD WARMERS ITEM PART NUMBER DESCRIPTION 1 2 3 4 5 6 7 76835 76836 76837 76838 76839 76840 76841 76842 76843 76844 77075 77076 67005 76100 55564-EGO 87054-EGO 87053-EGO 55825 76805 76806 76807 76808 76809 76810 76811 76812 76813 76814 77060 77061 75801 75833 75830 75851 75873 75874 75461 75813 75814 75852 75875 75876 75802 75820 75831 75853 75877 75878 75803 75804 75805 75854 75855 75856 75819 75821 75822 75857 75858 75859 HOUSING FD18 HOUSING FD24 HOUSING FD30 HOUSING FD36 HOUSING FD
FD-18 Thru FD-96 EXPLODED VIEW 9 10 8 6 7 15 14 16 18 11 2 17 12 2 3 1 4 5 3 13 67177 REV-11/2001 13
MODEL “FDL” LIGHTED OVERHEAD WARMERS REPLACEMENT PARTS CATALOG FDL Followed by 18, 24, 30, 36, 42, 48, 54, 60, 66, 72, 84, or 96 MODEL VOLTS HIGH WATTAGE FDL18 120 208 230 240 120 208 230 240 120 208 230 240 120 208 230 240 120 208 230 240 120 208 230 240 120 208 230 240 120 208 230 240 208 230 240 208 230 240 208 230 240 208 230 240 480 462 441 480 655 637 602 655 840 822 772 840 1080 1044 992 1080 1260 1224 1158 1260 1425 1389 1309 1425 1585 1549 1456 1585 1840 1796 1700 1850 1986 1874 2040 2166 203
FDL18 THRU 96 LIGHTED OVERHEAD WARMERS ITEM PART NUMBER DESCRIPTION 1 2 3 4 5 6 7 76845 76846 76847 76848 76849 76850 76851 76852 76853 76854 77080 77081 67004 76100 55564-EGO 87054-EGO 87053-EGO 55825 76805 76806 76807 76808 76809 76810 76811 76812 76813 76814 77060 77061 75801 75833 75830 75851 75873 75874 75461 75813 75814 75852 75875 75876 75802 75820 75831 75853 75877 75878 75803 75804 75805 75854 75855 75856 75819 75821 75822 75857 75858 75859 75806 75807 75808 75860 75861 75862 75823 HOUSING FDL
FDL-18 Thru FDL-96 EXPLODED VIEW 9 10 8 6 7 14 18 21 17 19 20 11 23 15 OO FN F 2 3 16 1 2 4 5 22 12 3 13 67178 REV 11/01 16
MODEL “FDD” or “FDDL” DUAL OVERHEAD WARMERS REPLACEMENT PARTS CATALOG FDD or FDDL Followed by 18, 24, 30, 36, 42, 48, 54, 60, 66, 72, 84, or 96 HIGH WATTAGE UNITS LENGTH 18 18 18 18 24 24 24 24 30 30 30 30 36 36 36 36 42 42 42 42 48 48 48 48 54 54 54 54 60 60 60 60 66 66 66 72 72 72 84 84 84 96 96 96 FDD SERIES 120V 800W 208V 800W 230V 735W 240V 800W 120V 1150W 208V 1150W 230V 1057W 240V 1150W 120V 1520W 208V 1520W 230V 1396W 240V 1520W 120V 1840W 208V 1840W 230V 1690W 240V 1840W 120V 2200W 208V 2200W 230
FDD or FDDL18 THRU 96 DUAL OVERHEAD WARMERS ITEM PART NUMBER DESCRIPTION 1 2 3 4 5 6 7 76855 76856 76857 76858 76859 76860 76861 76862 76863 76864 77085 77086 67004 76100 55564-EGO 87054-EGO 87053-EGO 55825 76985 76986 76987 76988 76989 76990 76991 76992 76993 76994 76995 76996 75801 75833 75830 75851 75873 75874 75461 75813 75814 75852 75875 75876 75802 75820 75831 75853 75877 75878 75803 75804 75805 75854 75855 75856 75819 75821 75822 75857 75858 75859 75806 75807 75808 75860 75861 75862 75823 75824 7
FDD or FDDL-18 Thru -96 EXPLODED VIEW 25 9 10 22 8 7 19 6 21 20 14 18 11 15 23 1 2 24 12 17 3 16 4 5 13 FDDL-REV112001.
9. APW WYOTT EQUIPMENT LIMITED WARRANTY APW Wyott Foodservice Equipment Company warrants it's equipment against defects in materials and workmanship, subject to the following conditions: This warranty applies to the original owner only and is not assignable. Should any product fail to function in its intended manner under normal use within the limits defined in this warranty, at the option of APW Wyott such product will be repaired or replaced by APW Wyott or its Authorized Service Agency.