Thermostats HEATING 70 72 SAFETY & INSTALLATION INSTRUCTIONS Model S86W MUPR Wi-Fi Thermostat with IAQ READ AND SAVE THESE INSTRUCTIONS
TABLE OF CONTENTS INSTALLATION ���������������������������������������������������������������������3 Installation Location Recommendations ������3 Outdoor Temperature Sensor (included) ������4 Remote Temperature Sensor (optional) ���� 6 Wireless Sensors ������������������������������������������������������ 8 Thermostat Mounting �������������������������������������������� 9 Power and Reset Options �����������������������������������10 Wiring Terminal ��������������������������������������������������
OUTDOOR TEMPERATURE SENSOR (INCLUDED) Outdoor temperature can be measured by attaching the included 8052 sensor to the T1 and T2 terminals. The outdoor sensor must be enabled in the installer setup menu. Heat pump models can use the outdoor temperature to effectively utilize the heat pump: • When the outdoor temperature is lower than the Low Balance Point, the heat pump will be locked out and only auxiliary heating will be used to provide heating.
REMOTE TEMPERATURE SENSOR (OPTIONAL) A remote temperature sensor can be used for control if the thermostat is to be mounted in a concealed location or a remote sensor can be averaged with the thermostat sensor to control a large space. An 8051 flush mount or 8053 surface mount remote temperature sensor can be attached to the T1 and T2 terminals and mounted in a recommended area.
WIRELESS SENSORS This thermostat is compatible with the following AprilAire wireless sensors: • Model Z10IDT Indoor Temperature and Humidity Sensor Up to eight of these sensors can be connected to the thermostat. Connected sensors will automatically be averaged, or individual sensors can be selected for scheduled events. • Model Z10ODT Outdoor Temperature and Humidity Sensor One sensor can be connected to the thermostat. The wireless sensor settings can be found under the thermostats’ installer settings.
POWER AND RESET OPTIONS The thermostat is powered from 24VAC. In the case of power loss, the thermostat will maintain the clock for 2 hours. The thermostat has a memory backup that saves the thermostat settings in case of power interruption. The thermostat can be set back to factory defaults from the installer settings menu. See Installer System Settings section for details. The factory reset does not clear thermostat account information from the AprilAire Wi-Fi Thermostat App.
WIRING DIAGRAMS FIGURE 5 – SINGLE & MULTI STAGE HEAT/COOL, ONE TRANSFORMER NOTE: Dashed lines represent wiring for multi stage systems only.
FIGURE 7 – SINGLE & MULTI STAGE HEAT PUMP, ONE TRANSFORMER NOTE: Dashed lines represent wiring for multi stage systems only.
FIGURE 9 – RADIANT & HEAT PUMP, ONE TRANSFORMER RH JUMPER RC W 24V COM E/W2 Y Y NC(2) AA COM(3) 8024 NO(4) R W G C C O/B R O/B W2 W Y2 Y T2 ODT/REMOTE TEMP SENSOR T1 I2 90-2678 C HUMIDIFIER SOLENOID DEHUMIDIFIER I2 I1 DRY CONTACT INPUT 90-2569 90-2570 AIR HANDLER W L 16 I2 I1 Y DEHUMIDIFIER (APRILAIRE SERIES 1800, e-SERIES) DUCT MOUNTED EVAPORATIVE HUMIDIFIERS (APRILAIRE SERIES 400, 500, 600, 700) TRANSFORMER O/B OUTDOOR UNIT R I1 FIGURE 10 - INDOOR AIR QUALITY EQUIPMEN
SETUP AND TESTING INSTALLER SETUP WIZARD AND INSTALLER SETTING The first time the thermostat is powered up (or after a factory reset) it will enter the Installer Setup Wizard. All Installer Settings can be set through this process. The Installer Settings are also accessible in the Installer Menu. HOW TO ENTER THE INSTALLER MENU: INSTALLER MENU OPTIONS HVAC Settings and for 3 seconds 3. Press and hold to unlock the Installer option. or to navigate to Installer, 4. Use press SELECT.
TABLE 1 – HVAC INSTALLER SYSTEM SETTINGS TABLE 1 – HVAC INSTALLER SYSTEM SETTINGS System setting Description Factory default setting (bold) and setting range Number of Compressor Stages Select number of compressor stages. (Heat Pump mode only.) One Two Number of Auxiliary Heat Stages Select number of auxiliary heat stages. (Heat Pump mode only.) One Two Number of Stages of Heat Select number of heat stages. (Heat/ Cool mode only.) One Two Number of Stages of Cool Select number of cool stages.
TABLE 1 – HVAC INSTALLER SYSTEM SETTINGS TABLE 1 – HVAC INSTALLER SYSTEM SETTINGS Factory default setting (bold) and setting range System setting Description Extended Fan – Heat Extends fan operation 90 seconds after heat call ends. NOTE: Only available with electric heat. Disabled Enabled Extended Fan – Cool Extends fan operation 90 seconds after cool call ends. Disabled Enabled Auto Changeover Enable or disable Auto Changeover mode. Disabled Enabled DeadBand Auto Changeover mode deadband.
TABLE 1 – HVAC INSTALLER SYSTEM SETTINGS TABLE 1 – HVAC INSTALLER SYSTEM SETTINGS Factory default setting (bold) and setting range System setting Description Factory default setting (bold) and setting range Recurrence Select number of months between HVAC Service reminder messages. 12 Months 1 to 12 Months Max Heat Setting Select the maximum heating set point temperature allowed. 90°F (32°C) 40 to 90°F (4.5 to 32°C) Min Heat Setting Select the minimum heating set point temperature allowed.
INDOOR AIR QUALITY SYSTEM SETTINGS TABLES TABLE 2 – HUMIDIFIER SYSTEM SETTINGS The following tables contain the Indoor Air Quality system settings and their details. Default settings are shown in bold. The availability of some settings is dependent upon the value of other settings. The use of outdoor temperature data enables additional Indoor Air quality functionality.
TABLE 2 – HUMIDIFIER SYSTEM SETTINGS TABLE 2 – HUMIDIFIER SYSTEM SETTINGS Factory default setting (bold) and setting range System setting Description Allowed Humidifier Operation Selects when humidification is allowed to occur relative to heating and fan operation. NOTE: Without Fan is only available when Humidifier Installed is set to Yes/Standalone. It allows humidification to occur without activating an HVAC fan and should only be used when the humidifier is mounted independently of any HVAC system.
TABLE 3 – DEHUMIDIFIER SYSTEM SETTINGS System setting Description TABLE 3 – DEHUMIDIFIER SYSTEM SETTINGS Factory default setting (bold) and setting range NOTE: Dehumidifier control can only be set to Whole Home if ventilation and humidification are not enabled. Dehumidifier Type Installed? Selects if a dehumidifier is installed. (If set to None, no other dehumidifier settings will be available.) AC w/ IAQ selects overcooling, I1 and I2 terminals energize during overcooling.
TABLE 4 – AIR CLEANING SYSTEM SETTINGS TABLE 5 – FRESH AIR VENTILATION SYSTEM SETTINGS Factory default setting (bold) and setting range System setting Selects if an air cleaner is installed. (If set to No, no other air cleaner settings will be available.) No Yes NOTE: Ventilation can only be installed if humidification is not enabled and dehumidifier control is not set to Whole Home. Air Cleaner Reminder Enable or disable the Change Air Filter message.
TABLE 5 – FRESH AIR VENTILATION SYSTEM SETTINGS TABLE 5 – FRESH AIR VENTILATION SYSTEM SETTINGS Factory default setting (bold) and setting range System setting Description Calculated Minutes Per Hour Displays the Fresh Air Time calculated. None Range 6 to 60 Minutes Override Manual adjustment of Calculated Minutes per Hour. (Calculated Minutes per Hour) Range 6 to 60 Minutes Outdoor Wired Temperature Sensor Installed? Selects how the external temperature sensor terminals (T1 & T2) are being used.
TABLE 5 – FRESH AIR VENTILATION SYSTEM SETTINGS TABLE 5 – FRESH AIR VENTILATION SYSTEM SETTINGS Factory default setting (bold) and setting range System setting Description Sets high ventilation temperature lockout limit. (Only available if High Vent Temperature Limit is set to Enabled.) 100°F (38°C) 85°F to 105°F (29°C to 41°C) Low Mixing Temperature Enables low mixing temperature. (Only available is HVAC Fan with Vent is set to Yes with high and low limits.
QUICK REFERENCE TO CONTROLS & DISPLAY SYSTEM TEST MENU The system test menu is used to test a system after installation. The Installer Test can be accessed from the Installer Menu. All equipment outputs that are configured in the installer settings can be turned on and off for testing equipment. Minimum on and off times are not enforced while in this mode. The instructions below show how to enter the test mode and turn outputs on and off. ENTER THE SYSTEM TEST MENU SYSTEM TEST STEPS 1.
MAIN MENU SCREEN SAVER Starts 45 seconds after inactivity, press any button to wake the screen. Main Menu Mode Fan CURRENT TIME Hold Schedule Main Menu Heat Blast Mode Away Fan Humidifier Hold Dehumidifier Schedule Ventilation Heat Blast 11:11 AM ROOM TEMPERATURE INDOOR RH% 70 55% 84° Indoor RH Outside Air Cleaning Vacation Settings OUTDOOR TEMPERATURE Item availability based on installed options.
TROUBLESHOOTING DISPLAY IS BLANK TEMPERATURE SETTINGS DO NOT CHANGE • Check circuit breaker and reset if necessary. • Make sure heating and cooling temperatures are set to acceptable ranges: • Make sure power switch at heating & cooling system is on. • Make sure furnace door is closed securely. HEATING SYSTEM DOES NOT RESPOND (“HEATING” APPEARS ON SCREEN) • Check for 24VAC at the equipment on the secondary side of the transformer between power and common.
THERMOSTAT FEATURES ERROR CODES If the thermostat enters an error mode, all outputs are turned off. The thermostat attempts to recover every 10 minutes. Error Code Message Error Description E01 Sensor Error Internal temperature & RH sensor failure E03 EEPROM Error Error in permanent memory E06 Remote Sensor Error Open remote temperature sensor circuit E07 Remote Sensor Error Shorted remote temperature sensor circuit • Remote access and control over Wi-Fi. • Indoor air quality control.
SPECIFICATIONS ENVIRONMENT Temperature Operating: 32° to 120°F (0° to 48.9°C) Shipping: -30° to 150°F (-34.4° to 65.5°C) Relative humidity Operating: 5% to 90% R.H. (non-condensing) ELECTRICAL Operating voltage 24VAC (18–30VAC) Current Maximum: 2.5A (total), 1.