Measurement Guide

OPERATION
The AprilAire E100 Dehumidiers are designed to dehumidify the air coming into the
unit by passing the incoming air over an evaporator coil, dropping the air temperature
below the dew point. The moisture is removed from the air and drains out of the
dehumidier to a common oor or waste drain. The air is then reheated in the
condenser coil and exits the unit.
Dehumidication occurs until the relative humidity (%RH) setting is reached. The unit
then shuts off until periodic sampling determines the need for dehumidication.
The integrated digital display and control monitors the %RH during sampling of the
incoming room or HVAC return air.
APPLICATION
AprilAire E100 Dehumidiers are the perfect product for whole-home dehumidication,
basements, crawl spaces and sealed attics.
VENTILATION
All E100 models have the ability to bring in fresh, outdoor air into the living space. Fresh
air will dilute stale air and pollutants and will reduce humidity in the winter months. If the
humidity level of the outdoor air higher than the %RH setting, the dehumidier will begin
dehumidication to reduce the humidity in the home to set humidity level. The outdoor
fresh air is brought in through 6" round duct with a 6" round, normally closed damper. This
complies with ASHRAE 62.2, Energy Star, and International Residential Code (IRC).
The dehumidier has built-in controls to adjust the amount of fresh air that is brought
in to the home. If wired to the HVAC system, the dehumidier will bring in the outdoor
air when the HVAC system calls for heating, cooling, or is running continuous fan.
If the amount of set ventilation time has not been met during the HVAC calls, the
dehumidier will open the ventilation damper and turn on the HVAC fan and bring in
fresh air until the ventilation time has been met.
High and low temperature limits are available in 3 different modes, preventing outdoor air
that is too hot or too cold from being delivered to the home. If the outdoor temperature
rises above the high limit or drops below the low limit, ventilation will not occur. If the
outdoor temperature drops below the heat only limit, ventilation will be allowed only
when the HVAC system is calling for heat. A high indoor %RH limit is also available in all
three ventilation modes.
ZONED DEHUMIDIFICATION
The E100 Dehumidiers are capable of zoned dehumidication. In this application,
the dehumidier can control the humidity in two separate zones in the home, a Primary
and Secondary Zone.
The submittal is intended to show general, overall product dimensions and provide
guidance for installation clearance. Drawings are not to scale. Ensure submittals are
current. AprilAire reserves the right to make product changes without notication
or obligation.
SPECIFICATIONS
Capacity
(1)
@ 80°F/60% RH
@ 73°F/60% RH
100 ppd
85 ppd
Energy Factor
(1)
@ 80°F/60% RH
@ 73°F/60% RH
2.6 L/kW-h
2.35 L/kW-h
Airflow @ varying E.S.P.
(external static pressure
- dry coil)
0.0" w.c.
0.2" w.c.
0.4" w.c.
280 CFM
245 CFM
210 CFM
Voltage, phase, frequency
120 VAC, 1 Phase, 60Hz
Current draw
(1)
6.9 Amps
Noise
55 dBA ducted
Dimensions
(cabinet only)
(2)
Width: 14"
Height: 15"
Length: 26"
Unit Weight
Shipping Weight
64 lbs.
82 lbs.
Leveling Feet
E100/E100H Only
Casters
E100C Only
Control
(3)
Built-in digital control with display
Control mounting option
Field-interchangeable from top to front
Cabinet insulation
1
2" EPS
Air discharge
Top or end
Inlet/Outlet duct collars
10" dia.
Backdraft damper at
outlet
Included
Filter
Washable MERV 8 (Part Number 5881)
Refrigerant
R410A
Coil type
Corrosion-resistant aluminum
8' Power cord
(4)
Plug type (E100, E100C only)
Hardwire option
Yes (E100H only)
Discharge air
temperature rise
10°F–30°F
Drain connection
(5)
3
4" MNPT Threaded
Included drain tubing
10' length (E100C only)
Warranty
5 Years
(1)
Rated capacity, energy factor and current draw measured at 80°F/60% RH inlet air at 0.0 ESP.
(2)
Height does not include adjustable feet. The width excludes the filter doors and length excludes the
duct collars.
(3)
Built-in automatic control capable to be set up for dehumidification and ventilation or zoning.
(4)
Model E100H is a hardwired unit and doesn’t ship with a power cord.
(5)
Threaded barbed fitting included.
90-2634
Project: ____________________________________
Architect: __________________________________
Contractor: _________________________________
Suppliers: ___________________________________
Dealer: _______________________________________________
Engineer: _____________________________________________
Location: ______________________________________________
Date: _________________________________________________
Dehumidier
MODELS:
E100: Includes 8' power cord
E100C: Uses casters instead of leveling feet
E100H: Terminal connection for hardwiring
Form No. Sub-E100 • 316431 • 04.23
© 2023 AprilAire | aprilairepartners.com | 800.334.6011
AprilAire reserves the right to change specifications without notice.
5-year warranty on all
installed products
(warranty does not apply to lters)
SUBMITTAL