Product Overview

SPECIFICATIONS
Capacity
@ 80°F/60% RH
@ 73°F/60% RH
80 ppd
65 ppd
Energy Factor
@ 80°F/60% RH
@ 73°F/60% RH
2.8 L/KW-h
2.35 L/KW-h
Airflow @ varying E.S.P.
(external static pressure - dry coil)
0.0" w.c
0.2" w.c
0.4" w.c
185 CFM
135 CFM
85 CFM
Voltage, phase, frequency 120VAC, 1 phase, 60 Hz
Current draw
(1)
5.1 Amps
Noise 45 dBA ducted
Dimensions:
(cabinet only)
(2)
Width 14"
Height 15"
Length 26"
Unit Weight
Shipping Weight
63 lbs.
81 lbs.
Inlet air operating conditions during
-Dehumidification:
50°F –104°F, 40°F
dew point min.
-Ventilation: 40°F–140°F,
0% –99% RH
(non-condensing)
(1)
Rated capacity, energy factor and current draw measured at 80°F/60% RH inlet air at 0.0 ESP.
(2)
Height does not include adjustable feet. The width excludes the filter doors and length
excludes the duct collars.
PRINCIPLE OF OPERATION
The Aprilaire E080CS Crawl Space Dehumidifier is designed to
dehumidify the air coming into the unit by passing the incoming air
over an evaporator coil to drop the air temperature below the dew
point of the air. Moisture is removed from the air and drained out of the
unit. The air is then reheated in the condenser coil and exits the unit.
Dehumidification occurs until the set point is reached, then shuts
o until periodic sampling determines a need for operation.
APPLICATION
The Model E80CS controls to a “Dew Point” set point which is ideal
for unconditioned spaces. It removes up to 80 pints per day with
a low current draw—keeping crawl spaces dry without unwanted
increases to the utility bill.
This unit also includes a crawl space alert which is an LED installed
in the living space that ensures homeowners their Model E80CS is
functioning properly. The light turns on to notify homeowners that
the unit is in need of service.
CIRCULATION
The Model E080CS can be programmed to circulate the air within a
crawl space. This evens out relative humidity levels and temperature
in the space, eliminating variations in the environment.
Crawl Space Dehumidifier
Model E080CS | Specification Sheet
FEATURES
Control Built-in digital control with top
or front mounting options
Crawl space alert 40' Cable with LED light
Cabinet insulation ½" EPS
Air discharge orientation Top or end
Inlet/Outlet duct collars 10" dia.
Backdraft damper at outlet Not included
Filter Washable MERV 8
(Part Number 5881)
Refrigerant R410A
Coil type Corrosion-resistant aluminum
8' Power cord Plug type
Hardwire option
Yes, field-configurable
Discharge air temperature rise
10°F–30°F
Drain connection
(3)
¾" PVC adapters
Included drain tubing 10' length
Warranty 5 Years
(3)
Adapters for threaded connection or plastic hose included.

Summary of content (2 pages)