Specification

PRINCIPLE OF OPERATION
The Aprilaire E080 Dehumidiers are designed to dehumidify
the air coming into the unit by passing the incoming air over an
evaporator coil to drop the air temperature below the dew point
of the air. Moisture is removed from the air and drained out of the
unit to a common oor or waste drain. The air is then reheated in
the condenser coil and exits the unit.
Dehumidication occurs until the set point is reached, then shuts
off until periodic sampling determines a need for operation.
APPLICATION
The E080 Dehumidiers are perfect for a wide range of
applications, including whole-home dehumidication and
control of moisture in basements and crawl spaces.
CIRCULATION
The E080 can also be programmed to circulate the air
within a crawl space. This evens out relative humidity levels
and temperature in the space, eliminating variations in the
environment.
Built-in automatic digital control with display.
Can be set up for dehumidication and
ventilation or zoning.
Top or front mounting control options
½” EPS cabinet insulation
Top or end air discharge orientation
Washable MERV 8 lter (part number 5881) and
10” diameter inlet/outlet duct collars
Backdraft damper at outlet
R410A refrigerant
Corrosion-resistant aluminum coils
8’ power cord (plug type - E080 only; E080H is
a hardwired unit and doesn’t ship with a powercord)
Field-congurable hardwire option is available
10°F-30°F discharge air temperature rise
¾” MNPT Threaded drain connection with adapters for
threaded connection or plastic hose included
5-year warranty
FEATURES
SPECIFICATIONS
Capacity
@ 80°F/60%RH
@ 73°F/60% RH
80 ppd
65 ppd
Energy Factor kW-h
@ 80°F/60% RH
@ 73°F/60% RH
2.8 L/KW-h
2.35 L/KW-h
Airflow @ varying E.S.P.
(external static pressure - dry coil)
0.0” w.c.
0.2” w.c.
0.4” w.c.
185 CFM
135 CFM
85 CFM
Voltage, phase,
frequency
120 VAC, 1 phase, 60 Hz
Current draw
(2)
5.1 Amps
Noise
45 dBA ducted
Dimensions (cabinet only)
(3)
Width: 14”, Height: 15”, Length: 26”
Unit Weight
Shipping Weight
63 lbs.
81 lbs.
Inlet air operating
conditions during
Dehumidification:
50°F –104°F, 40°F
dew point min.
Ventilation:
40°F–140°F,
0% –99% RH
(non-condensing)
(2)
Rated capacity, energy factor and current draw measured at 80°F/60% RH inlet air at 0.0 ESP.
(3)
Height does not include adjustable feet. The width excludes the lter doors and length excludes
the duct collars.
MODELS:
E080: Includes 8 ft. power cord
E080H: Terminal connection for hardwiring
SPECIFICATION
Model E080
DehumidierDehumidier

Summary of content (2 pages)