Measurement Guide

MODELS:
E080: Includes 8’ power cord
E080H: Terminal connection for hardwiring
90-2634
Project: ____________________________________
Architect: __________________________________
Contractor: _________________________________
Suppliers: ___________________________________
Dealer: _______________________________________________
Engineer: _____________________________________________
Location: ______________________________________________
Date: _________________________________________________
Dehumidier
SPECIFICATIONS
Capacity
(1)
@ 80°F/60% RH
@ 73°F/60% RH
80 ppd
65 ppd
Energy Factor
(1)
@ 80°F/60% RH
@ 73°F/60% RH
2.8 L/kW-h
2.35 L/kW-h
Airflow @ varying E.S.P.
(external static pressure - dry coil)
0.0” w.c.
0.2” w.c.
0.4” w.c.
185 CFM
135 CFM
85 CFM
Voltage, phase,
frequency
120 VAC, 1 Phase, 60Hz
Current draw
(1)
5.1 Amps
Noise
45 dBA ducted
Dimensions
(cabinet only)
(2)
Width: 14”
Height: 15”
Length: 26
Unit Weight
Shipping Weight
63 lbs.
81 lbs.
Control
(3)
Built-in digital control with display
Control mounting option
Top or front-mounting options
Cabinet insulation
1
2 EPS
Air discharge orientation
Top or end
Inlet/Outlet duct collars
10” dia.
Backdraft damper at
outlet
Included
Filter
Washable MERV 8 (Part Number 5881)
Refrigerant
R410A
Coil type
Corrosion-resistant aluminum
8' Power cord
(4)
Plug type (E080 only)
Hardwire option
Yes, (E080H only)
Discharge air
temperature rise
10°F–30°F
Drain connection
(5)
3
4 MNPT Threaded
Warranty
5 Years on all parts
(1)
Rated capacity, energy factor and current draw measured at 80°F/60% RH inlet air at 0.0 ESP.
(2)
Height does not include adjustable feet. The width excludes the lter doors and length excludes the
duct collars.
(3)
Built-in automatic control capable to be set up for dehumidication and ventilation or zoning.
(4)
Model E130H is a hardwired unit and doesn’t ship with a power cord.
(5)
Threaded barbed tting included
The submittal is intended to show general, overall product
dimensions and provide guidance for installation clearance.
Drawings are not to scale. Ensure submittals are current.
AprilAire reserves the right to make product changes without
notication or obligation.
OPERATION
The AprilAire E080 Dehumidiers are designed to dehumidify the air coming into the unit by passing the
incoming air over an evaporator coil, dropping the air temperature below the dew point. The moisture
is removed from the air and drains out of the dehumidier to a common oor or waste drain. The air is
then reheated in the condenser coil and exits the unit.
Dehumidication occurs until the relative humidity (%RH) setting is reached. The unit then shuts off until
periodic sampling determines the need for dehumidication. The integrated digital display
and control monitors the %RH during sampling of the incoming room or HVAC return air.
APPLICATION
The E080 Dehumidiers are the perfect product for whole-home dehumidication, basements, crawl
spaces and sealed attics.
VENTILATION
The E080 has the ability to bring in fresh, outdoor air into the living space. Fresh air will dilute stale air
and pollutants and will reduce humidity in the winter months. If the humidity level of the outdoor air
higher than the %RH setting, the dehumidier will begin dehumidication to reduce the humidity in the
home to set humidity level. The outdoor fresh air is brought in through 6” round duct with a 6” round,
normally closed damper. This complies with ASHRAE 62.2, Energy Star, and International Residential
Code (IRC).
The dehumidier has built-in controls to adjust the amount of fresh air that is brought in to the home.
If wired to the HVAC system, the dehumidier will bring in the outdoor air when the HVAC system calls
for heating, cooling, or is running continuous fan. If the amount of set ventilation time has not been met
during the HVAC calls, the dehumidier will open the ventilation damper and turn on the HVAC fan and
bring in fresh air until the ventilation time has been met.
High and low temperature limits are available in 3 different modes, preventing outdoor air that is too
hot or too cold from being delivered to the home. If the outdoor temperature rises above the high limit
or drops below the low limit, ventilation will not occur. If the outdoor temperature drops below the heat
only limit, ventilation will be allowed only when the HVAC system is calling for heat. A high indoor %RH
limit is also available in all three ventilation modes.
ZONED DEHUMIDIFICATION
The E080 Dehumidiers are capable of zoned dehumidication. In this application, the dehumidier can
control the humidity in two separate zones in the home, a Primary and Secondary Zone.
Form No. Sub-E080 • 316430 • 04.23
© 2023 AprilAire | aprilairepartners.com | 800.334.6011
AprilAire reserves the right to change specifications without notice.
34”
14”
15”
26”
4”4”
10”
DIA.
10”
DIA.
15
7
10
3
4 DIA. PIPE, INSIDE
1
2
5 TO 2
5-year warranty on all
installed products
(warranty does not apply to lters)