Chapter A. Event Reporting
inputs shall be optically isolated from the rest of the system. Reset is accom-
plished by asserting a voltage differential from 3.3 VDC to –48 VDC for
between 200ms and 300ms.
The supported voltage range shall be from 0 to –48VDC continuous, up to –
60VDC at a 50% duty cycle, and up to –72VDC at a 30% duty cycle. The cur
-
rent drawn by this input may be as high as 12mA with no damage resulting
from a reversal in polarity.
A.2 PacketMax 5000 and PacketMax 100 Alarms
Table A-2 shows the MSC Alarms that are generated in the base station. Table A-3
shows the WSC Alarms that are generated in the base Station.
NOTE: Events are highlighted in brackets in the following tables.
Table A-1 Pin Description of Telco
Pin Description
1 Minor Reset+
2 Minor Reset+
3 Major Reset-
4 Major Reset-
5 Critical Alarm-NO
6 Critical Alarm-NC
7 Critical Alarm-Com
8 Minor Alarm-NO
9 Minor Alarm-NC
10 Minor Alarm-COM
11 Major Alarm-NO
12 Major Alarm-NC
13 Major Alarm-COM
14 Power Alarm-NO
15 Power Alarm-Com