Instructions / Assembly

15
3. Point W Waste water connection:
Tubing color: Black tubing. Connect the BLACK tubing from the RO to the Drain Saddle.
Fitting type: Quick-Connect fitting on drain saddle. No teflon tape.
Do Not add ”insert into Black tubing. Simply push tubing into port.
4. Point A System water inlet (to Stage 1 prefilter) connection:
Tubing color: Red tubing. Connect the RED tubing from the Feed Water Valve to the RO’s stage -1
prefilter.
Fitting type: Quick Connect fitting See Fig.1 on page 4. Simply push the Red tubing into the Quick
Connect fitting. No Inserts, Sleeves or Nuts are needed to secure the connection. No
teflon tape needed here.
5. Point H Stage-5 filtered water to faucet connection:
Tubing color: Clear tubing. Connect the CLEAR tubing from the faucet base stud to the Stage-5 filter’s
outflow end at point H. (See “Flow -->” arrow on the filter for flow direction.)
Fitting type: Quick Connect fitting See Fig.1 on page 4. Simply push the Clear tubing into outlet
on the 5th stage filter. No Inserts, Sleeves or Nuts are needed to secure the
connection. No Teflon tape needed here.
Please Note: There are two end plugs on the stage 5 filter that has to be removed before
inserting the tubing. Please refer to Fig. 1A on page 4 for removal instruction.
6. Point G Stage-5 filter’s T-fitting connection:
Tubing color: Yellow tubing. Connect the YELLOW tubing to Stage-5 filter’s T-fitting.
Fitting type: Quick Connect fitting See Fig.1. Simply push the Yellow tubing into the 5th stage filter’s
T Fitting. No Inserts, Sleeves or Nuts are needed to secure the connection. No Teflon tape
needed here.
(Note: If the unit comes with a UV Light, connect the Yellow tubing to the T- fitting on the
UV, as the Stage 5 filter will not have a T-fitting).