User's Manual

Back-UPS Pro Gaming UPS 1500 VA 9
Status Indicators
Troubleshooting
Unit Status
Description
Standby
When the unit is plugged into the AC outlet but is turned off, LCD will display
battery capacity, input voltage and mute icon. LED ring will be in customized
color. In standby mode, the connected equipment will not be protected.
UPS is turning on All LEDs will light up and the colors will slowly cycle among all available
colors. The process should take about 10 seconds.
Equipment is
plugged in
The Reactor circle will show the load percentage. The Rear LEDs do not
change. Rear LEDs will return to idle state after 10 seconds.
Equipment is
unplugged
The Reactor circle will show the load percentage. Rear LEDs do not change.
Rear LEDs will return to idle state after 10 seconds.
Idle State This animation occurs after 10s of inactivity.
This occurs every time except when UPS has detected a system error.
Rear LED doesn’t change (keeps custom/default color).
Idle state color is defined by the custom color that user selects (default white).
LED illumination in idle state is always at 60% intensity.
Press a button The LCD will be lit. The unit will switch to idle state after 10 seconds of inactivity.
Power Outage
(unit goes on
battery)
The Reactor circle will light up to show the runtime percentage, and the
displayed percentage will reduce as the runtime reduces. The
reactor circle
color
will be green and blinking if battery life is above 50%, orange and
pulsing when battery life is between 20% and 50%, red and flashing when
battery life is under 20%.
Low Battery
When the unit is on battery and the battery capacity is low (i.e. when the unit
continuously beeps) the reactor circles that is still on will turn red and pulsing -
regardless of the color you have selected. The backlight will match this
functionality - but only when lighting is enabled.
Overload
The reactor circle lights
up in red. It will remain in this state until the unit is
no longer overloaded.
Dead Battery
The reactor circle lights
up in red. It will remain in this state until the battery
is charged or replaced
Building Wiring
Fault
The reactor circle lights
up in red and pulsing. It will remain in this state
until the building wiring fault is no longer detected
Power Surge All LEDs light up in your chosen color
Rear LED has same behavior as Reactor circle.
Power Dip
All LEDs light up in your chosen color
Rear LED has same behavior as Reactor circle.
LCD Information
LCD will cycle through different information when
INFORMATION
button is
pressed. The information will be cycle from Event counter Runtime Load
watt Load VA Load percentage Output voltage Output frequency
Input voltage LCD off.
When Runtime is displayed, the Reactor circle color will be green and blinking
if battery life is above 50%, orange and pulsing when battery life is between
20% and 50%, red and flashing when battery life is under 20%
When Load percentage is displayed, the LED ring color will be green.