Version 1.
ArcPad 48 Integral (SmartWhite) Table of contents 1. Safety instructions ...................................................................................................................................................... 3 2. Fixture exterior view ................................................................................................................................................... 5 3. Installation ..............................................................................................
ArcPad 48 Integral (SmartWhite) FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING YOUR ArcPad 48 Integral ! Save it for future reference. This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual.
ArcPad 48 Integral (SmartWhite) When choosing the installation spot, please make sure that the fixture is not exposed to extreme heat or dust. Avoid using the unit in locations subject to possible impacts. The fixture body never must be covered with cloth or other materials. Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened. Make sure that the area below the installation place is blocked when rigging, derigging or servicing the fixture.
ArcPad 48 Integral (SmartWhite) 2. Fixture exterior view 1. Lens array 2. Radiator 3.Base 6. Power/data cord 3. Installation 3.1 Mounting the fixture The ArcPad 48 Integral can be arranged in any position orientation.The ArcPpad 48 Integral´s radiator with LEDs is mounted on an adjustable bracket for “tilt” adjustment into many positions: Two slots (8.
ArcPad 48 Integral (SmartWhite) Ensure that the structure to which you are attaching the fixture is secure Caution: Overhead installation requires experience. Fixtures may cause severe injuries when crashing down! If you have doubts concerning the safety of a possible installation, do not install the device and consult installation with an expert. 3.
ArcPad 48 Integral (SmartWhite) .
ArcPad 48 Integral (SmartWhite) 3.3 Installation of the barn-doors You can install the barn-doors to better define illuminated surface. To install the barn-door module: 1. Disconnect the fixture from the mains. 2. Put the top edge of the barn-doors module into the second groove on the top side of the radiator ( detail A) and the bottom edge into the second groove on the bottom side of the radiator and tighten four locking screws M2 to secure this barn-doors module on the radiator.
ArcPad 48 Integral (SmartWhite) 3.4 Setting and control For setting DMX address, selecting DMX mode and for another settings you need either Robe Universal Interface or the RDM Communicator. Please see the Robe Universal Interface or RDM Communicator user manuals to get more information about this products. The way, how to connect these interfaces to the DMX data link is figured below. NOTE: never connect the RDM communicator and the The Robe Universal Interface to the fixture at the same time.
ArcPad 48 Integral (SmartWhite) 3.5 DMX 512 connection To build a DMX chain 1. Connect the DMX output of the controller directly with the DMX input of the first fixture in the DMX chain. 2. Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next fixture. 3. Always connect the DMX output with the input of the next fixture until all fixtures are connected. Do not overload the link. Max. 32 fixtures may be connected on a DMX link.
ArcPad 48 Integral (SmartWhite) 4. ArcPad 48 Integral (SmartWhite) - DMX protocol Version 1.
ArcPad 48 Integral (SmartWhite) 5. Control menu map Default settings=Bold print Menu Level 1 Menu Level 2 Menu Level 3 A001 dM.Ad. 001-512 MA.SL. d.AbL Menu Level 4 MASt. SLA InFo Poti. FuLL totL rSEt EcO totL rSEt DM.In. Stro 0-255 : F.dim tEMP. 0-255 Cur.t. Hi.tE. rSEt PErS VErS. IC1 dM.Pr. Mod.1 Mod.2 Mod.3 dISP. d.On On, Off d.Int. 3,60,100 turn tEM.U. °C, °F LOAd FuLL EcO In.Po. WWhi.
ArcPad 48 Integral (SmartWhite) Menu Level 1 Menu Level 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 : F.dim 0-255 Stor. dFSE MAn.M. PrE.C. Man.C. WWhi Wh.01..Wh.03 dimr di.01...di.06 WWhi 0-255 dimr 0-255 F.dim 0-255 tESt St.AL. Auto Off tESt PrG.1 : PrG.3 PLAY tESt PrG.1 : PrG.3 Edit PrG.1 St.01 P.End 1-68 : : Stro. 0-255 PrG.3 St.68 : : S.tim. 0-25.5 sec CoPY SPEC. rdML rdMH Adj. DMH WWhi.
ArcPad 48 Integral (SmartWhite) Menu Level 1 Menu Level 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 dimr CaL.U. Wh.1.1 : Wh.1.4 Stor. uPd.M. 6. Fixture menu RDM communicator: Connect the RDM communicator to the fixture and from the menu “Control” select the “Remote LED display” item. The fixture´s control display with the four control buttons will appear on the screen of the RDM communicator.
ArcPad 48 Integral (SmartWhite) The Remote LED Display window will appear. Now you can fullly control the fixture using the UP, Down, Enter, Escape and Reset buttons. 6.1 Fixture Address Use this menu to set the DMX address of the fixture or set the fixture as a Master (Slave). dM.Ad. --- DMX addressing. Select this submenu to set a DMX start address.
ArcPad 48 Integral (SmartWhite) To set a DMX address. 1. Use the UP/DOWN buttons to find “ A001“ menu. 2. Press the ENTER button. 3. Use the UP/DOWN buttons to select desired start address. 4. Press the ENTER button to confirm the choice. MA.SL. --- Master/slave addressing. Select this submenu to set the fixture as a master or slave. Option "d.AbL" deactivates master/slave setting. To set a fixture as a master or slave. 1. Use the UP/DOWN buttons to find “A001“ menu. 2. Press the ENTER button. 3.
ArcPad 48 Integral (SmartWhite) rSEt --- the menu item shows the maximum temperatures of the fixture inside since the counter was last reset. In order to reset this counter to 0 you have to press and hold the UP and DOWN buttons and at the same time press the ENTER button. Note: The ambient temperature should not exceed 40°C. The temperatures can be displayed in either °C or °F units - see option “tEM.U“ in the menu “Pers“. VErS. ---Software Versions.
ArcPad 48 Integral (SmartWhite) 9. Press the ENTER button and use the UP/DOWN buttons to set value , press the ENTER button to confirm it. 6. 5 Test sequences Use this menu to run demo-test sequences without an external controller, which will show you some possibilities of using the ArcPad 48 Integral. 6.6 Stand-alone setting The fixtures on a data link are not connected to the controller but can execute pre-set programs which can be different for every fixture.
ArcPad 48 Integral (SmartWhite) “cWhi” – a cool white Leds saturation (0-255) “Stro.“ - a strobe, shutter (0-255) “dimr“ - a dimmer (0-255) “F.dim“ - a fine dimmer (0-255) “F.tim.“ - a fade time, (0-25.5) seconds “S.tim.“ - step time, value (0-25.5) seconds “COPY“. – this item duplicates the current prog. step to the next prog. step. The item “P.End” is increased automatically. 6. Use the UP/DOWN buttons to set a DMX value of the channel and then press the ENTER button. 7.
ArcPad 48 Integral (SmartWhite) 4 Press the ENTER button 5 Use the UP/DOWN buttons to select “ yES“ option 6 Press the ENTER button Note: If you do not want to continue in software update, you have to switch off and on the fixture to escape from this menu. 3. Disconnect the RDM communicator from the fixture. 4. Connect serial port of your PC with a DMX input of the fixture if you using the flash cable RS232/DMX. If you use the Robe Universal Interface: 1.
ArcPad 48 Integral (SmartWhite) If the connection is OK, click on the Start Uploading button to start uploading. It will take several minutes to perform software update. If the option "Incremental Update" is not checked, all processors will be updated (including processors with the same software version). If you wish to update only the latest versions of processors, check the Incremental Update box. Avoid interrupting the process. Update status is being displayed in the Info Box window.
ArcPad 48 Integral (SmartWhite) STATUS_MESSAGES * STATUS_ID_DESCRIPTION * DEVICE_HOURS * Please, see the Robe Universal Interface user manual for detail description of RDM operation. 8. Error and information messages t.M.Er.(Temperature measuring error) The message informs you that the LED module temperature sensor is defective. MA.Er. (Master error) The fixture is set as a master and DMX console is connected to the fixture.
ArcPad 48 Integral (SmartWhite) 9. Technical specifications Power supply • Electronic auto-ranging • Input voltage: 100 - 240V AC, 50-60 Hz • Fuse: T 2.5A H • Power consumption: Power mode Full mode Eco mode Max.
ArcPad 48 Integral (SmartWhite) Dimensions (mm) ArcPad 48 Integral Junction box Weight • 3 kg 24
ArcPad 48 Integral (SmartWhite) Protection factor • IP 67 Included items • 1 x ArcPad 48 Integral • 1 x Junction box (No.99012672) • 1 x User manual • 1 x Gasket of cable grommet M20, PF ½ (P.N. 1305 1388) Optional accessories • 1 x Barn-doors module in silver colour (No. 10980090) • Eggcrate top hat module without lenses (No. 10980091) • Flash cable RS232/DMX (No.
ArcPad 48 Integral (SmartWhite) 10. Cleaning and maintenance DANGER ! Disconnect from the mains before starting any cleaning or maintenance work Rinse off loose dirt with low pressure water spray. Wash the housing with a soft brush or sponge and a mild, nonabrasive washing detergent. Rinse it. There are no serviceable parts inside the device. Maintenance and service operations are only to be carried out by a qualified person. Should you need any spare parts, please use genuine parts.
ArcPad 48 Integral (SmartWhite) 27