User's Manual

4. Commissioning
Page 34 User’s Manual for ION
®
-U
figure 4-14 Mains power connector figure 4-15 Mains power cable - AC
The Mains cable is part of the delivery. It’s available in two wiring configurations:
Wiring 1
Pin Name Color
1 Phase Black
2 Neutral White
3 n.c. n.c
PE Ground Green
Wiring 2
Pin Name Color
1 Phase Brown
2 Neutral Blue
3 n.c. n.c
PE Ground Green/Yellow
table 4-3 AC power cable pinning
For the AC power supply connection, a minimum cross section of 1.5
mm
2
is required. Each wire must observe the applicable national
regulations regarding loop impedance, voltage drop, and methods of
installation. Make sure to connect the correct voltage to the unit.
Note: Do not connect or disconnect the power cord at the mains connector while
power is on. Turn off mains* power before connecting the power cord at
the Remote Unit, then, engage mains again.
* Mains power must be interrupted with an external mains breaker. For the mains breaker, observe
the following recommendation:
120 Volt / 20 Amp max. or 240 Volt / 16 Amp, single-phase, 50 / 60 Hz AC service is needed, i.e. the
external AC breaker should be 20 Amps max. for 120-Volt service or 13 - 16 Amps for 240-Volt
service.