6. Warning and Safety Requirements
Environmental Conditions
This equipment is designed to be installed in indoor environments.
Operating temperature: +5 to +40°C
Do not install in corrosive atmosphere or in critical environmental conditions such as hazardous
classifi ed areas
(1)
.
Installation Site Features
A trained technician should carry out the installation of the master unit. Since the system is
designed for indoor installation, the master unit should be installed in a dry and suitable location
where:
there is no risk of explosion;
the environment is not classifi ed as a high-risk one in case of fi re;
suspended particles are not to be found in great concentration;
there is no risk of traffi c which could cause
collision damages;
the site is properly located with respect to the ergonomic positioning of the working
environments;
the system is placed in a private room, protected against any possible violation;
there is no direct sunlight or where water may drip on the device (for example under air-
conditioning equipment).
the site must be accessible by maintenance personnel;
the site must be dry, with low humidity;
the site must guarantee proper space for cables and natural ventilation for the system;
2 meters must be kept between the rack and any heating opening.
The remote units should be mounted in reasonable locations as well:
do not install remote units inside heating or conditioning areas;
do not install remote units inside cable pipelines or fi re-prevention sites (fi re escapes, lift
tunnelss, emergency exits; which have to guarantee defi ned safety standards);
take into consideration that the temperature in the upper part of a room is higher than at
the 2 meter height. For false ceiling installation of case-A and case-B remote units, verify that
the environment temperatures do not exceed allowed limits;
each remote unit requires its own power and a connection to the mains might be needed;