User guide

NetLinx Programming
94
MAX-CSE/MAX-CSD10 Operation/Reference Guide
IR / Serial Ports Channels
IR/Serial Port (Port 3) Commands
The IR port is located at Port 3 in NetLinx D:P:S nomenclature. The following IR and IR/Serial
Send_Commands generate control signals for external equipment.
In these examples: <DEV> = device. The IR port shall support the following commands.
IR / Serial Ports Channels
00001 - 00229 IR commands.
00229 - 00253 May be used for system call feedback.
00254 Power Fail. (Used with the 'PON' and 'POF' commands).
00255 Power status. (Shadows I/O Link channel status).
IR/Serial Send_Commands
Command Description
CAROFF
Disable the IR carrier signal
until a 'CARON' command is
received.
Syntax:
SEND_COMMAND <DEV>,"'CAROFF'"
Example:
SEND_COMMAND IR_1,"'CAROFF'"
Stops transmitting IR carrier signals to the IR_1 port.
CARON
Enable the IR carrier signals
(default).
Syntax:
SEND_COMMAND <DEV>,"'CARON'"
Example:
SEND_COMMAND IR_1,"'CARON'"
Starts transmitting IR carrier signals to the IR_1 port.
CH
Send IR pulses for the
selected channel.
All channels below 100 are transmitted as two digits. If the IR code for ENTER
(function #21) is loaded, an Enter will follow the number. If the channel is
greater than or equal to (>=) 100, then IR function 127 or 20 (whichever exists)
is generated for the one hundred digit. Uses 'CTON' and 'CTOF' times for pulse
times.
Syntax:
SEND_COMMAND <DEV>,"'CH',<channel number>"
Variable:
channel number = 0 - 199.
Example:
SEND_COMMAND IR_1,"'CH',18"
This device performs the following:
Transmits IR signals for 1 (IR code 11). The transmit time is set with the
CTON command.
Waits until the time set with the CTOF command elapses.
Transmits IR signals for 8 (IR code 18).
Waits for the time set with the CTOF command elapses.
If the IR code for Enter (IR code 21) is programmed, the device performs
steps 5 and 6.
Transmits IR signals for Enter (IR code 21).
Waits for the time set with the CTOF command elapses.