Installation Instructions
11
AmeriVent Round and Oval Gas Vent
Installation Instructions
4. There must be nothing else in the stud bay other than
the Vent and furnace. This includes any type of
insulation.
5. The installation must contain an Oval Hold-Down Plate
(4OHD) at the base, Oval Plate Spacers (4OPS) at the
first ceiling level, and Firestop Spacers (4OPS) at any
additional floor levels. See Figures 18 and 19.
Installation of Type B-W Gas Vent
1. Cut out the ceiling plate at the floor level above the
heater flush with studs in space where Vent is to
be installed.
2. Nail one AmeriVent Plate Spacer (40PS), (A), across
cut-out area in ceiling plate. See Figure 18. Plate
Spacer (4OPS) is required at the first ceiling level
above a wall furnace to center and space vent properly
and to provide the required opening between floors.
3. Snap Hold-Down Plate (4OHD), (B), onto bottom end
of AmeriVent pipe as shown in Figure 18. Install Vent
Section in position. Use two No. 8 binder head sheet
metal screws to attach Hold-Down Plate firmly to
Furnace header plate through pre-punched holes.
4. Nail second AmeriVent Plate Spacer across cutout
ceiling plate as shown in Figure 18. Firestop Spacers
(OFS) must be used at subsequent levels.
5. If the Vent is to continue additional stories within a 2x4
stud space, install Firestop Spacers at the second and
subsequent ceiling levels as shown in Figure 19.
6. After passing through the last Firestop Spacer, the
Vent may be finished with either round or oval
AmeriVent fittings, flashings and AmeriVent Cap.
(Round pipe, fittings, flashings, and vent caps cost less
than corresponding oval parts.)
Attic Insulation Shield
In some areas, the building code requires the use of an
attic insulation shield (AVS) on single-story Type B-W
installations.
Termination of Vent Structure
The AmeriVent Gas Vent is available for most models and
sizes in two styles of Termination Tops--AmeriVent Cap and
Universal Cap. The AmeriVent Cap is a lock-neck design
with the same lock as the female end of the Vent sections.
The Universal Cap is designed to fit inside the inner wall of
the vent sections.
American Metal Products 12" and smaller Gas Venting
Systems, using either the AmeriVent Cap or the Universal
Cap, may terminate in accordance with Table 7 and
Figures 20 and 21.
B
Type B-W
Installation
Figure 18
A
Multi-Story Type B-W Installations
AT SECOND AND
SUBSEQUENT CEILING
LEVELS, USE 40FS
FIRESTOP SPACERS.
AT FIRST CEILING LEVEL,
USE 40PS CEILING
PLATE SPACERS.
Figure 19