Installation Guide

- 2 -
1
M965726 Rev. 1.0 (7/16)
2
HANDLE INSTALLATION
TRIM INSTALLATION
Install HANDLE ADAPTER (1) onto TEMPERATURE CONTROL KNOB (2)
and tighten with SCREW (3).
Align HANDLE (4) and push onto TEMPERATURE CONTROL KNOB (2).
Tighten SET SCREW (5) in handle with HEX WRENCH (6) SUPPLIED.
5
OPERATING THE VALVE
Turn on water supply on and test installed tting.
If the system is delivering all Hot or all Cold and no mixed water the pipes are probably
transposed. See step 3 for TRANSPOSED SUPPLY PIPING.
Operate valve from off to cold to hot. Check temperature. If max mixed water temperature
is to hot or to cold see step 4 and re-calibrate the valve.
1
3
PINS
2
6
5
GREASE ESCUTCHEON
O-RING SEAL
4
1
3
2
4
5
6
3
TRANSPOSED SUPPLY PIPING OR BACK TO BACK INSTALLATION
Should the hot and cold water supply pipes have been transposed
making adjustment impossible, proceed as follows:
Shut off water supply.
Remove handle and rim
Remove check stops and re-install them transposed.
Important note: RED CHECK STOP is now on the right of the mixer body
and the BLUE CHECK STOP is now on the left.
Turn the water supply back on and perform the temperature adjustment
in step 4.
OFF
COLD
HOT
4
TEMPERATURE CALIBRATION
Check that arrow marking B points vertically upwards. If not, push the BLACK
CLAMP (1) on the SECURING RING (2) to the right, pull off KNOB MOUNT (3) and
reinstall KNOB MOUNT (3) with arrow “B” pointing upwards.
SET HOT LIMIT STOP
– The maximum mixed water temperature is set at 109°F at the factory.
This setting can be changed if desired.
– Remove the TEMPERATURE LIMIT STOP (4) (H shaped Red Plastic part).
Reinstall it at the desired notch as indicated in the diagram to limit the
maximum mixed water temperature to 104°F or 112°F.
For 100°F adjustment, turn the water supply on. Turn KNOB MOUNT (3) until the
spout temperature is 100°F. Check that arrow marking A on the KNOB MOUNT (3)
still points upward after adjusting the thermostat to 100°F. If not, pull out the RED
LOCKING DEVICE (5). Remove KNOB MOUNT (3) without turning by sliding out
as indicated by the arrow.
Reinstall the KNOB MOUNT (3) so that the arrow marking A points upwards.
Reinstall RED LOCKING DEVICE (5).
CHECK STOP
(RED TO BLUE)
CHECK STOP
(BLUE TO RED)
1
3
5
2
4
ARROW
"A"
ARROW
"B"
104
109
112
Push CAP (1) over the O-RING SEAL (2).
Push ESCUTCHEON HOLDER (3) with lightly greased
O-RING SEAL (4) over CAP (1). Attach with the two
SCREWS (5) provided.
Align pins in back of ESCUTCHEON (6) with holes in
ESCUTCHEON HOLDER (3). Push ESCUTCHEON (6)
ush against nished wall.