Installation Guide

- 2 -
2
M965830 (6/17)
MAKE WATER SUPPLY CONNECTIONS
LOOP SUPPLIES
IF REQUIRED
28"
1
2
COLD
COLD
HOT
HOT
Figure A.
Turn off hot and cold water supplies before beginning.
Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies.
Connection on tting supplies are 3/8" compression.
Connectleft supply to Hot and right supply to the Cold
wall supply. Use adjustable wrench to tighten connections.
Do not over tighten.
Faucet supplies are 28" long from faucet base.
Note: If additional supply length is required,
installer must purchase additional parts separately.
Important: If SUPPLY HOSES (1, 2) are
too long, loop as illustrated to avoid kinking.
Figure A.
PUTTY
2
1
3
4
5
3
DRAIN INSTALLATION
Apply a bead of PUTTY to underside of DRAIN BODY
FLANGE (1).
Feed DRAIN BODY (1) down through lavatory.
Assembly GASKET (2) WASHER (3) and LOCKNUT (4)
onto DRAIN BODY (1). Tighten LOCKNUT (4) rmly.
Assembly TAILPIECE (5) to DRAIN BODY (1).