9
M965218 REV 1.6
IS STOP VALVE OPEN?
TRY MANUAL VALVE BUTTON;
WILL THE UNIT FLUSH?
NO REPLACE PISTON KIT
NO REPLACE SENSOR
NO
YES
YES
YES
OPEN VALVE
UNIT WILL ONLY FLUSH MANUALLY
RETRY AUTOMATIC FLUSH.
DOES THE UNIT FLUSH?
RETRY AUTOMATIC FLUSH.
TEST SENSOR. DISCONNECT
SENSOR CABLE FROM
COVER AND RE-CONNECT. SENSOR
SHOULD FLASH FOR 5 SECONDS.
DOES IT FLASH?
TEST SENSOR. DISCONNECT
SENSOR CABLE FROM COVER
AND RE-CONNECT. SENSOR
SHOULD FLASH FOR 5 SECONDS.
DOES IT FLASH?
CLOSE STOP VALVE,
REPLACE SOLENOID KIT.
RE-ASSEMBLE & INSTALL UNIT.
OPEN STOP VALVE.
NO
NO
YES
DOES THE SENSOR FLASH
FOR THE FIRST 5 SECONDS?
NO REPLACE SOLENOID KIT
RETRY AUTOMATIC FLUSH;
WAS IT SUCCESSFUL?
1. COVER SENSOR FOR 10 SECONDS
2. UNCOVER SENSOR FOR 10 SECONDS.
MANUAL VALVE
OBSTRUCTED.
CLOSE STOP VALVE
AND SERVICE
RETRY AUTO FLUSH
UNIT IS CONTINUOUSLY FLUSHING
PUSH MANUAL FLUSH
BUTTON; DOES IT RETURN?
NO
YES
YES
NO
1. COVER SENSOR FOR 10 SECONDS
2. UNCOVER SENSOR FOR 10 SECONDS.
DOES THE UNIT STOP FLUSHING?
YES
1. CLOSE STOP VALVE,
2. REPLACE SOLENOID KIT.
3. RE-ASSEMBLE AND INSTALL UNIT.
4. OPEN STOP VALVE.
REPLACE SENSOR
NO
TROUBLESHOOTING FLOW CHARTS
UNIT DOES NOT FLUSH AT ALL
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1 (800) 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Product names listed herein are trademarks of AS America, Inc.
IN MEXICO 01-800-839-12-00