TROUBLE SHOOTING GUIDELINES
Heaters
All heaters are equipped with a preset pressure switch which will not allow the heater to turn on if the
pump is not running with water flowing through the whirlpool system. The heater includes an
exclusive High Limit Switch. This safety circuit will not false trip from hot tap water. It will turn
off the heater is the thermostat fails. If your whirlpool is equipped with adjustable jets, or other flow
control systems, the pre set pressure may not activate the heater. To assure proper heater operation,
all jets may need to fully open with the pump operating at or near maximum flow.
Heater Will Not Operate – Check For:
Improper or loose connections, open switches or relays, blown circuit breakers.
Wiring, loose connections etc.
Overload. (Amperage Reading.)
O-Zone Generators
All O-Zone Generators are equipped with a preset vacuum switch which will not turn on if the pump
is not running with water flowing through the whirlpool system. The O-Zone Generator includes an
exclusive High Limit Switch and will not false trip from tap water. If your whirlpool is equipped
with adjustable jets, or other flow control systems, the pre set vacuum may not activate the generator.
To assure proper operation, all jets may need to fully open with the pump operating at or near
maximum flow.
O-Zone Generator Will Not Operate – Check For:
Improper or loose connections, open switches or relays, blown circuit breakers.